Selection Guide

Selection Guide

 
Class MD Vario LK4 VLS GS2
Type

Motor disconnect switches

Manual motor control switches

Nonfusible IEC style disconnect switches

Disconnect switches

Disconnect switches

Fusible IEC style disconnect switches

UL Rating

UL 508

UL 508

UL 98

UL 508

UL 98

UL 98

Handle Type

Rotary

Rotary

Rotary

Rotary

Rotary

Rotary

Mounting

Door or panel

DIN Rail (Rear Mounting)
Door Mounting

DIN Rail (Rear Mounting)
Door Mounting

Flange with cable mechanism panel

Voltage (max.)

600 Vac

600 Vac

600 Vac

690 Vac

690 Vac

600 Vac

Current Ratings

30–60

10–115

30–1200

16–63 A

63–125 A

30–800

Horsepower Ratings (max.)

7.5–40

2–60

7.5–500

1–30

3–60

7.5–500

Enclosure Type

Non-Metallic
NEMA 1, 3, 3R, 4, 4X, and 12

Metallic:
NEMA 1, 12, 4, 4X

Plastic:
IP55, NEMA Type 4X

Handle ratings:
NEMA 1, 3R, 4, 4X, 12

NEMA 1, 12, 3R, 4, and 4X; IEC IP65, IP66

NEMA 1, 12, 3R, 4, and 4X; IEC IP65, IP66

Handle ratings:
NEMA 1, 3R, 4, 4X, 12

Accessories

Power poles and auxiliary contacts

Power poles and auxiliary contacts

Auxiliary contacts and power lugs

Power poles and auxiliary contacts

Power poles and auxiliary contacts

Auxiliary contacts and power lugs

Approvals

UL File E164864
IEC standard 60947-3

UL File E164864 NLRV
CSA File LR 81630
Class 3211 05

UL File E191098 WP2X / WP2X7
CSA 703149
Class 4652 04

UL File E487906
UL60947-4-1/CSA 22.2 n° 60947-4-1-14

UL File E487907
UL98/CSA 22.2 n° 4

UL File E191098 WP2X / WP2X7
CSA 703149
Class 4652 04

Page

MD Motor Disconnect Switches

Mini-Vario

LK4 NonFusible Disconnect Switches

TeSys™ VLS Disconnect Switches

TeSys™ VLS Disconnect Switches

GS2 Fusible Disconnect Switches

 
Class 9422 9421 9422 9423
Type

NEMA style fused or non-fusible disconnect switches

Circuit breaker
operating mechanisms

Circuit breaker
operating mechanisms

Door closing mechanisms

UL Rating

UL98

Handle Type

Flange
Adjustable rod or cable mechanism

Rotary

Flange
Adjustable rod or cable mechanism

Rotary, works in conjunction with 9422 handle mechanisms

Mounting

Panel or bracket mount

Panel

Panel

Load Voltage (max.)

600 Vac

600 Vac

600 Vac

Current Ratings

30–400

Circuit breaker frame sizes 100–1200

Circuit breaker frame sizes 100–1200

Horsepower Ratings (max.)

7.5–350

Enclosure Type

Handle ratings:
NEMA 1, 3R, 4,
4X, 12

Handle ratings:
NEMA 1, 3R, 4,
4X, 12

Handle ratings:
NEMA 1, 3R, 4,
4X, 12

Handle ratings:
NEMA 4 and 12
sheet steel or stainless

Accessories

Auxiliary contacts

Auxiliary contacts

Auxiliary contacts

Right or left-hand operation

Approvals

UL File E52639 WHTY2
CSA LR44199
Class 4652-04

UL File E62922 DIHS2
CSA LR44199
Class 3211 07

UL File E62922 DIHS2
CSA LR44199
Class 3211 07

Page

Disconnect Switches

Type L Circuit Breaker Mechanisms

Flexible Cable Mechanisms

Door Closing Mechanisms