Wall Duct
Refer to Busway and Cable Management Online
Wall Duct General Description
UL Listed, File E65247, for Enclosure of Wiring to X-Ray Machines. Also available in aluminum for MRI application.
Wall duct is used as the continuation for standard trench duct in the floor. Wall duct can be routed up the wall and across the ceiling or under the finished floor (in ceiling space below) to provide a continuous lay-in raceway system from control consoles and floor equipment to overhead apparatus. Devices are furnished complete with covers and are available for either flush or surface mounted installations.
General Notes:
-
Standard construction is 14 gauge steel with gray electrodeposition paint. Alternate construction is painted aluminum.
-
Covers and coupling devices are furnished with each device.
-
Wire retainers are furnished with each device.
-
Straight lengths are field cut to length.
-
Partitions and tunnels are to be field modified and installed where required.
-
Hangers or other mounting devices to be furnished by others.
Components and Accessories
Lay-In Wall Duct Components [1] [2]
|
Component |
Flush Cover |
Surface Cover |
|||
|---|---|---|---|---|---|
|
Catalog Number |
Weight Lbs. |
Catalog Number |
Weight Lbs. |
||
|
5'–0" Straight Length With Cover |
6"W 10"W 18"W |
22.5 39.2 62.2 |
20.4 36.4 59.4 |
||
|
1'–6" Straight Length With Cover |
6"W 10"W 18"W |
12.6 16.4 23.3 |
12.6 16.3 23.3 |
||
|
Horizontal Elbow With Cover—90o |
6"W 10"W 18"W |
6.5 9.3 24.9 |
6.0 8.1 23.7 |
||
|
Horizontal Elbow With Cover—45o |
6"W 10"W 18"W |
— — — |
— — — |
6.0 8.1 23.7 |
|
|
Edgewise Elbow With Cover |
6"W 10"W 18"W |
5.5 7.5 11.1 |
5.5 7.4 11.0 |
||
|
Tee With Cover |
6"W 10"W 18"W |
6.2 8.5 24.1 |
5.9 7.3 22.9 |
||
|
Cross With Cover |
10"W 18"W |
1.3 1.8 |
6.2 21.8 |
||
|
Flanged Cabinet Connector With Cover |
10"W |
8.0 |
7.8 |
||
|
Reverse Edgewise Elbow With Cover |
6"W 10"W 18"W |
5.8 7.5 11.1 |
5.7 7.4 11.0 |
||
|
Sweep Edgewise Elbow With Cover |
6"W 10"W 18"W |
— |
10.0 12.0 16.5 |
4.8 11.8 16.3 |
|
|
Sweep Edgewise Elbow Cabinet Connector |
10"W 18"W |
— — |
— — |
14.0 20.0 |
|
Wall Duct Accessories
Lay-In Wall Duct Accessories [1] [2]
|
Accessories |
Catalog Number |
Weight |
|
|---|---|---|---|
|
5'–0" Partition |
5.4 |
||
|
Straight through tunnel for tees [3] |
10"W 18"W |
2.9 3.8 |
|
|
90o Elbow tunnel for crosses [3] |
10"W 18"W |
3.2 5.1 |
|
|
3 compartment tunnel for tees |
10"W 18"W |
5.0 6.0 |
|
|
3 compartment tunnel for crosses |
10"W 18"W |
8.0 9.0 |
|
|
Edgewise Tee Kit |
10"W 18"W |
1.3 2.1 |
|
|
Sweep Edgewise Tee Kit |
10"W 18"W |
8.0 8.0 |
|
|
Flush to Surface Adaptor |
10"W 18"W |
11.9 16.4 |
|
|
Ceiling Drop-Out |
12x12 Flush Cover 8"x8" |
15.0 |
|
|
Extra Coupling Device 10"W 18"W |
10"W 18"W |
.4 .5 |
|
|
Extra Straight Cover—30" long |
Flush 10"W Flush 18"W Surface 10"W Surface 18"W |
7.2 13.0 6.1 11.8 |
|
Wall Duct Accessories [1] [2]
|
Accessories |
Catalog Number |
Weight |
|
|---|---|---|---|
|
Reducer Coupling |
18" to 10" 10" to 6" |
2.1 |
|
|
Cabinet Connector |
6"W 10"W 18"W |
1.0 |
|
|
End Cap |
6"W 10"W 18"W |
1.0 |
|
|
Vertical Elbows for: |
6" Trench to 6" Wall Duct 12" Trench to 10" Wall Duct 12" Trench to 18" Wall Duct 18" Trench to 10" Wall Duct 18" Trench to 18" Wall Duct |
1.1 1.2 |
|
|
Sweep Trench Duct to Wall Duct Adapter |
12" Trench to 10" Wall Duct 18" Trench to 18" Wall Duct |
10.0 |
|
|
Split Cover with Grommet 12" long–3"x 8" Opening |
Flush 6"W Flush 10"W Flush 18"W Surface 6"W Surface 10"W Surface 18"W |
2.6 2.0 |
|
|
Dust Cover—5 ft. long |
5.5 |
||
|
Grommet—100 ft. roll |
|||