Search Results: POWER PACT P BUS

Search Results: POWER PACT P BUS

Showing 21 - 30 of 763 results

Page 3 of 78
  • Homeline™ Miniature Circuit Breakers

    Section 7: Miniature and Molded Case Circuit Breakers

  • Mission Critical Circuit Breakers

    Section 7: Miniature and Molded Case Circuit Breakers

  • PowerPacT™ Circuit Breaker Accessories

    Section 7: Miniature and Molded Case Circuit Breakers

  • PowerPacT Family

    Section 7: Miniature and Molded Case Circuit Breakers

    Designation Interrupting Rating Terminations B 125 A Frame 240 Vac 480 Vac 600Vac A I-Line H 150 A Frame B 10 kA — — L Lugs on Both Ends J 250 A Frame D 25 kA 18 kA 14 kA F Bus Bar (No Lugs) Q 250 A Frame G 65 kA 35 kA 18 kA M Lugs Line Side Only L 600 A Frame J 100 kA 65 kA 25 kA P Lugs Load End Only M 800 A
  • PowerPacT H-, J-, and L-Frame Trip Units

    Section 7: Miniature and Molded Case Circuit Breakers

    /6.3E only) Power and energy measurement Power quality measurements Current demand and power demand measurements PowerPacT H, J and L-Frame MicroLogic Trip Units PowerPacT H, J and L-Frame MicroLogic Trip Units PowerPacT H, J and L-Frame MicroLogic Trip Units MicroLogic Trip Unit Settings for H-, J
  • Multi9 Circuit Breakers Busbar Offer

    Section 7: Miniature and Molded Case Circuit Breakers

    BP (UL489) Comb Busbars supplementary protectors, Multi9™ busbars Multi9™ busbars circuit breakers miniature, Multi9™ busbars These comb busbars are aimed to be used only with C60 BP circuit-breakers. They perform distribution and subdistribution of the electric power supply and allow rapid
  • Accessories

    Section 7: Miniature and Molded Case Circuit Breakers

    Retaining Kit QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual power supply applications. Can be used with (2) 2Ps or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers. QO2DTIM DE2E OBS This product is obsolete. QO1PA
  • M-Frame Circuit Breakers

    Section 7: Miniature and Molded Case Circuit Breakers

    480 Vac Common mounting holes, handle locations and trim dimensions with shared auxiliaries and accessories with P-frame devices Available in standard (80%) rating only UL, CSA, NOM, IEC, CCC certified, and UKCA and CE marked for global acceptance M-Frame 800 A, Basic Electronic Trip System Type ET
  • UL Listed 500 Vdc Circuit Breakers

    Section 7: Miniature and Molded Case Circuit Breakers

    voltage of 500 Vdc or a maximum floating (unloaded) voltage of 600 Vdc. Suitable for use only with UPS (ungrounded uninterruptable power supplies systems).This two-level voltage rating allows these circuit breakers to be applied to battery sources having a short-circuit availability of 20,000
  • Instantaneous Trip Circuit Breakers

    Section 7: Miniature and Molded Case Circuit Breakers

Page 3 of 78