7EN02–0305–02

Switchboard meter with rear breakout panel

  Connector Connection detail

A

Ethernet (option)

If equipped, use Cat 5 UTP cable to connect to LAN/WAN.

B

Modem (option)

If equipped, use RJ11 telephone cord to connect to modem line.

C

I/O Expander (option)

If you are installing the optional I/O Expander, see “Connecting I/O Expander option to meter with breakout panel”, below for details.

D

COM1 RS-232

See “RS-232 connections” .

E

Chassis ground

See “Step 3: Prepare the ground connections”.

F

Digital inputs

If equipped, S1, S2, S3, SCOM

G

IRIG-B

Connect to IRIG-B time sync output signal device.

H

Digital outputs

If equipped, C1, C2, C3, C4

I

COM1 RS-485 & COM2 or COM4 RS-485

 

J

Auxiliary power supply (option)

If equipped, see “Step 4: Connect the optional auxiliary power”.

Connecting I/O Expander option to meter with breakout panel

Using the cable that came with your I/O Expander, connect the 14-pin male Molex connector end to the meter and connect the 24-pin male Molex connector end to the I/O Expander.

NOTE: Only use the I/O connectors on the I/O Expander. The communications ports on the I/O Expander are disabled when it is connected to a meter with breakout panel option.
QR Code is a registered trademark of DENSO WAVE INCORPORATED in Japan and other countries.