Ring and Ringless Type Individual Meter Sockets
Class 4131 / Refer to Catalog 4100CT0701
Individual Meter Sockets
|
This metering is generally utility specific. Always check with local utility company before installing. Contact your nearest Field Sales Office for additional catalog numbers, if required by utility.
Individual Meter Sockets
Ampere Rating [1] |
Jaw |
Service |
Cat. No. [2] |
Lug Wire Range (Al/Cu) |
Enclosure Information |
Box No. [3] |
||||
---|---|---|---|---|---|---|---|---|---|---|
Line, Load, |
Wire |
Gnd. |
Material |
Top Endwall Conf. Order Separately |
||||||
Hub |
Closing Plate [4] |
|||||||||
Ringless Type, 1Ø3W 600 Vac Max., Without Bypass or Jaw Release |
||||||||||
125 |
4 |
UG |
UTZRS101A OBS[5] |
8–2/0 |
1/2 in. Hex |
14–2 |
Steel |
Solid Top [5] |
— |
1R |
125 |
4 |
OH |
8–2/0 |
Slotted |
14–2 |
Steel |
Series A |
ACP |
1R |
|
125 |
4 |
OH |
UATRS101B OBS |
8–2/0 |
Slotted |
14–2 |
Aluminum |
Series A |
ACPA |
1R |
125 |
4 |
OH |
8–2/0 |
Slotted |
14–2 |
Steel |
Series A |
ACP |
1R |
|
125 |
5 |
OH/UG |
1003880A OBS[6] |
8–2/0 |
Slotted |
14–2 |
Steel |
Series A |
ACP |
1R |
125 |
4 |
OH/UG |
8-2/0 |
1/2 in. |
14-2 |
Steel |
Series A |
ACP [7] |
1R |
|
200 |
4 |
OH |
8–250 |
1/2 in. Hex |
14–2 |
Steel |
Series A |
ACP |
3R |
|
200 |
4 |
OH |
UATRS202B OBS |
8–250 |
1/2 in. Hex |
14–2 |
Aluminum |
Series A |
ACPA |
3R |
200 |
4 |
UG |
1/0–350 |
1/2 in. Hex |
14–2 |
Steel |
Solid Top [5] |
— |
5R |
|
200 |
4 |
OH/UG |
1/0–350 |
1/2 in. Hex |
14–2 |
Steel |
Series A |
ACP |
5R |
|
200 |
4 |
OH/UG |
1/0–350 |
1/2 in. Hex |
14–2 |
Aluminum |
Series A |
ACPA |
5R |
|
200 |
4 |
OH/UG |
1/0–350 |
1/2 in. Hex |
14–2 |
Steel |
(2) Series A |
(2) ACP[8] |
7R |
|
200 |
4 |
OH/UG |
8-250 |
1/2 in. Hex 5/16 Allen |
None |
Steel |
Series A |
ACP [7] |
4R |
|
200 |
4 |
OH/UG |
8-350 |
1/2 in. Hex 5/16 Allen |
14-2 |
Steel |
(2) Series A |
(2) ACP [8] |
7R |
|
200 |
4 |
OH/UG |
8-250 |
1/2 in. Hex 5/16 Allen |
14-2 |
Steel |
Series A |
ACP [7] |
4R |
|
200 |
4 |
OH/UG |
8-350 |
1/2 in. Hex 5/16 Allen |
14-2 |
Steel |
Series A |
ACP [7] |
5R |
|
200 |
4 |
UG |
UTRS220A OBS |
3/8 in. Studs |
9/16 in. Hex |
14-2 |
Steel |
Solid Top [9] |
— |
15.13x13x5 inches |
200 |
4 |
UG |
8-350 |
1/2 in. Hex 5/16 Allen |
14-2 |
Steel |
Solid Top [9] |
— |
2R |
|
200 |
4 |
OH/UG |
8-350 |
1/2 in. Hex 5/16 Allen |
14-2 |
Steel |
Series A |
ACP [7] |
17.13x13x5 inches |
|
Ringless Type, 1Ø3W 600 Vac Max., With Test Switch |
||||||||||
20 | 8 | UG | #10 CU [10] | Studs | 14-2 | Steel | Solid Top [9] | — | 16.5x14x3.5 inches | |
Ringless Type, 3Ø4W 600 Vac Max., With Test Switch |
||||||||||
20 | 13 | UG | #10 CU [10] | Studs | 14-2 | Steel | Solid Top [9] | — | 16.5x14x3.5 inches | |
Ringless Type, 1Ø3W 600 Vac Max., With Horn Bypass, Without Jaw Release |
||||||||||
125 |
4 |
OH/UG |
8–2/0 |
Slotted |
14–2 |
Steel |
Series A |
ACP |
1R |
|
125 | 4 | OH/UG | 8-2/0 | Slotted | 14-2 | Steel | Series A | ACP | 1R | |
125 | 4 | OH/UG | 8-2/0 | Slotted | 14-2 | Steel | Series A | ACP | 1R | |
125 | 5 | OH/UG | 8-2/0 | Slotted | 14-2 | Steel | Series A | ACP | 1R | |
125 |
5 |
OH |
UGHTRS101L OBS[11] |
8–2/0 |
Slotted |
14–2 |
Steel |
A125 [11] |
— |
1R |
125 |
4 |
OH |
URS101BDQ OBS[12] |
8–2/0 |
1/2 in. Hex |
None |
Steel |
Series A |
ACP |
1R |
125 |
5 |
OH/UG |
UGHTRS111C OBS[7] |
8–2/0 |
Slotted |
14–2 |
Steel |
Series A |
ACP [7] |
4R |
200 |
4 |
OH/UG |
UBHMRS212B OBS[6] |
8–250 |
1/2 in. Hex |
None |
Steel |
Series A |
ACP |
4R |
200 |
4 |
OH |
8–250 |
1/2 in. Hex |
14–2 |
Steel |
Series A |
ACP |
3R |
|
200 |
4 |
OH/UG |
8–250 |
1/2 in. Hex |
14–2 |
Steel |
Series A |
ACP |
4R |
|
200 |
4 |
OH/UG |
1/0–350 |
1/2 in. Hex |
14–2 |
Steel |
Series A |
ACP |
5R |
|
200 |
4 |
UG |
1/0–350 |
1/2 in. Hex |
14–2 |
Steel |
Solid Top [5] |
— |
2R |
|
200 |
4 |
UG |
URS212ADQ OBS[12] |
8–250 |
1/2 in. Hex |
None |
Steel |
Solid Top [5] |
— |
4R |
200 |
4 |
OH/UG |
8-350 |
1/2 in. Hex 5/16 Allen |
14-2 |
Steel |
Series A |
ACP [13] |
5R |
|
200 |
4 |
UG |
Line 4/0 Comp Line Neut 2/0 Comp Load 6-250 |
9/16 in. Hex |
(2) 14-2 |
Steel |
Solid Top [9] |
— |
61x9x5 inches |
|
200 |
4 |
OH |
8-250 |
1/2 in. Hex 5/16 Allen |
14-2 |
Steel |
Series A |
ACP |
3R |
|
200 |
5 |
OH/UG |
8-350 |
1/2 in. Hex 5/16 Allen |
14-2 |
Steel |
Series A |
ACP |
5R |
|
200 |
5 |
OH/UG |
8-350 |
1/2 in. Hex 5/16 Allen |
14-2 |
Steel |
Series A |
ACP [13] |
5R |
|
Ringless Type, 1Ø3W 600 Vac Max., With Lever Bypass and Jaw Release |
||||||||||
200 |
4 |
OH |
UTH4203T OBS |
6–350 |
1/2 in. Hex |
14–2 |
Steel |
Series A-L |
ACPL |
8R |
200 |
4 |
OH/UG |
6–350 |
1/2 in. Hex |
14–2 |
Steel |
Series A-L |
ACPL |
9R |
|
200 |
5 |
OH |
UTH5203T OBS |
6–350 |
1/2 in. Hex |
14–2 |
Steel |
Series A-L |
ACPL |
8R |
200 |
5 |
OH/UG |
6–350 |
1/2 in. Hex |
14–2 |
Steel |
Series A-L |
ACPL |
9R |
|
320 |
4 |
OH/UG |
Studs Only |
3/8 in. dia. studs |
14–1/0 |
Steel |
Series A-L |
ACPL |
11R |
|
320 |
4 |
OH/UG |
Dual 6-350 |
5/16 in. Allen |
14-1/0 |
Steel |
Series A-L |
ACPL [13] |
34.5x16.44x6.5 inches |
|
200 |
5 |
OH/UG |
6-350 |
1/2 in. Hex 5/16 Allen |
14-2 |
Steel |
Series A |
ACP [13] |
9R |
|
320 |
4 |
OH/UG |
3/8 in. Studs |
9/16 in. Hex |
None |
Steel |
Series A-L |
ACPL [13] |
34.5x13x5 inches |
|
320 |
4 |
OH/UG |
3/8 in. Studs |
9/16 in. Hex |
14-1/0 |
Aluminum |
Series A-L |
ACPL [13] |
11R |
|
320 |
4 |
OH/UG |
Line 4-600 Load Dual 6-350 |
Line 1/2 in. Allen Load 5/16 in. Allen |
14-1/0 |
Steel |
Series A-L |
ACPL |
11R |
|
Ringless Type, 3Ø4W 600 Vac Max., With Lever Bypass and Jaw Release |
||||||||||
200 |
7 |
OH/UG |
6–350 |
1/2 in. Hex |
14–2 |
Steel |
Series A-L |
ACPL |
9R |
|
320 |
7 |
OH |
Studs Only |
3/8 in. dia. studs |
14–1/0 |
Steel |
Series A-L |
ACPL |
10R |
|
200 A |
7 |
OH/UG |
6-350 |
1/2 in. Hex 5/16 Allen |
None |
Steel |
Series A |
ACP [13] |
19x13x5 inches |
|
Ringless Type, 3Ø4W 600 Vac Max., Bolt-On Socket Without Bypass |
||||||||||
400 |
7 |
OH/UG |
UK7T OBS[14] |
Studs Only |
1/2 in.–20 |
1/2 in.–20 |
Steel |
Series A-L |
ACPL |
12R |
400 |
7 |
OH/UG |
UAK7T OBS[14] |
Studs Only |
1/2 in.–20 |
1/2 in.–20 |
Aluminum |
Series A-L |
ACPLA |
12R |
Ring Type, 1Ø3W 600 Vac Max., Without Bypass or Jaw Release |
||||||||||
125 |
4 |
OH/UG |
8–2/0 |
Slotted |
14–2 |
Steel |
Series A |
ACP |
1R |
|
200 |
4 |
OH/UG |
1/0–350 |
1/2 in. Hex |
14–2 |
Steel |
Series A |
ACP |
5R |
|
125 |
5 |
OH |
8-2/0 |
Slotted |
14-2 |
Steel |
Series A |
ACP |
1R |
|
200 |
5 |
OH |
8-250 |
1/2 in. Hex 5/16 Allen |
14-2 |
Steel |
Series A |
ACP |
3R |
|