Ring and Ringless Type Individual Meter Sockets

Class 4131 / Refer to Catalog 4100CT0701

Individual Meter Sockets

  • Available single or three phase, 600 Vac max., with and without horn or lever bypass, overhead and underground service feed.

  • 10 kA short circuit current rating (or higher with utility approval).

  • UL Listed, NEMA 3R enclosure.

  • Units supplied with bonded neutral.

  • Units supplied with hub opening in top endwall require the use of a bolt-on hub, or closing plate.

  • Units supplied with solid top are for underground feed only.

  • For accessories, refer to Meter Socket Accessories.

This metering is generally utility specific. Always check with local utility company before installing. Contact your nearest Field Sales Office for additional catalog numbers, if required by utility.

UTRS101B

UTRS202B

(Cover not shown)

UTH5203T

(Cover not shown)

URTRS213B

Individual Meter Sockets

Ampere Rating [1]

Jaw
Qty.

Service
Type

Cat. No. [2]

Lug Wire Range (Al/Cu)

Enclosure Information

Box No. [3]

Line, Load,
and Neutral
(AWG/kcmil)

Wire
Binding

Gnd.
(AWG)

Material

Top Endwall Conf.


Order Separately

Hub
Opening [4]

Closing Plate [4]

Ringless Type, 1Ø3W 600 Vac Max., Without Bypass or Jaw Release

125

4

UG

UTZRS101A OBS[5]

8–2/0

1/2 in. Hex

14–2

Steel

Solid Top [5]

1R

125

4

OH

UTRS101B  

8–2/0

Slotted

14–2

Steel

Series A

ACP

1R

125

4

OH

UATRS101B OBS

8–2/0

Slotted

14–2

Aluminum

Series A

ACPA

1R

125

4

OH

URS101BCPL

8–2/0

Slotted

14–2

Steel

Series A

ACP

1R

125

5

OH/UG

1003880A OBS[6]

8–2/0

Slotted

14–2

Steel

Series A

ACP

1R

125

4

OH/UG

UTZRS101CFL

8-2/0

1/2 in.

14-2

Steel

Series A

ACP [7]

1R

200

4

OH

UTRS202B

8–250

1/2 in. Hex

14–2

Steel

Series A

ACP

3R

200

4

OH

UATRS202B OBS

8–250

1/2 in. Hex

14–2

Aluminum

Series A

ACPA

3R

200

4

UG

UTRS213A [5]

1/0–350

1/2 in. Hex

14–2

Steel

Solid Top [5]

5R

200

4

OH/UG

UTRS213B [6]

1/0–350

1/2 in. Hex

14–2

Steel

Series A

ACP

5R

200

4

OH/UG

UATRS213B [6]

1/0–350

1/2 in. Hex

14–2

Aluminum

Series A

ACPA

5R

200

4

OH/UG

U92197CCCPL  [8]

1/0–350

1/2 in. Hex

14–2

Steel

(2) Series A

(2) ACP[8]

7R

200

4

OH/UG

1004710E

8-250

1/2 in. Hex 5/16 Allen

None

Steel

Series A

ACP [7]

4R

200

4

OH/UG

UT92197CCFL

8-350

1/2 in. Hex 5/16 Allen

14-2

Steel

(2) Series A

(2) ACP [8]

7R

200

4

OH/UG

UTRS212C

8-250

1/2 in. Hex 5/16 Allen

14-2

Steel

Series A

ACP [7]

4R

200

4

OH/UG

UTRS213CFL

8-350

1/2 in. Hex 5/16 Allen

14-2

Steel

Series A

ACP [7]

5R

200

4

UG

UTRS220A OBS

3/8 in. Studs

9/16 in. Hex

14-2

Steel

Solid Top [9]

15.13x13x5 inches

200

4

UG

UTRS223A

8-350

1/2 in. Hex 5/16 Allen

14-2

Steel

Solid Top [9]

2R

200

4

OH/UG

UTRS233C

8-350

1/2 in. Hex 5/16 Allen

14-2

Steel

Series A

ACP [7]

17.13x13x5 inches

Ringless Type, 1Ø3W 600 Vac Max., With Test Switch

20 8 UG

1007361C

#10 CU [10] Studs 14-2 Steel Solid Top [9] 16.5x14x3.5 inches

Ringless Type, 3Ø4W 600 Vac Max., With Test Switch

20 13 UG

1007003C

#10 CU [10] Studs 14-2 Steel Solid Top [9] 16.5x14x3.5 inches

Ringless Type, 1Ø3W 600 Vac Max., With Horn Bypass, Without Jaw Release

125

4

OH/UG

UHTRS101B

8–2/0

Slotted

14–2

Steel

Series A

ACP

1R

125 4 OH/UG

1004162A

8-2/0 Slotted 14-2 Steel Series A ACP 1R
125 4 OH/UG

UFHTRS101B

8-2/0 Slotted 14-2 Steel Series A ACP 1R
125 5 OH/UG

UGHTRS101B

8-2/0 Slotted 14-2 Steel Series A ACP 1R

125

5

OH

UGHTRS101L OBS[11]

8–2/0

Slotted

14–2

Steel

A125 [11]

1R

125

4

OH

URS101BDQ OBS[12]

8–2/0

1/2 in. Hex

None

Steel

Series A

ACP

1R

125

5

OH/UG

UGHTRS111C OBS[7]

8–2/0

Slotted

14–2

Steel

Series A

ACP [7]

4R

200

4

OH/UG

UBHMRS212B OBS[6]

8–250

1/2 in. Hex

None

Steel

Series A

ACP

4R

200

4

OH

UHTRS202B

8–250

1/2 in. Hex

14–2

Steel

Series A

ACP

3R

200

4

OH/UG

UHTRS212B [6]

8–250

1/2 in. Hex

14–2

Steel

Series A

ACP

4R

200

4

OH/UG

UHTRS213B [6]

1/0–350

1/2 in. Hex

14–2

Steel

Series A

ACP

5R

200

4

UG

UHTRS223A [5]

1/0–350

1/2 in. Hex

14–2

Steel

Solid Top [5]

2R

200

4

UG

URS212ADQ OBS[12]

8–250

1/2 in. Hex

None

Steel

Solid Top [5]

4R

200

4

OH/UG

1004159A

8-350

1/2 in. Hex 5/16 Allen

14-2

Steel

Series A

ACP [13]

5R

200

4

UG

1006388

Line 4/0 Comp Line Neut 2/0 Comp Load 6-250

9/16 in. Hex

(2) 14-2

Steel

Solid Top [9]

61x9x5 inches

200

4

OH

1007665

8-250

1/2 in. Hex 5/16 Allen

14-2

Steel

Series A

ACP

3R

200

5

OH/UG

UGHTRS213B

8-350

1/2 in. Hex 5/16 Allen

14-2

Steel

Series A

ACP

5R

200

5

OH/UG

UGHTRS213C

8-350

1/2 in. Hex 5/16 Allen

14-2

Steel

Series A

ACP [13]

5R

Ringless Type, 1Ø3W 600 Vac Max., With Lever Bypass and Jaw Release

200

4

OH

UTH4203T OBS

6–350

1/2 in. Hex

14–2

Steel

Series A-L

ACPL

 8R

200

4

OH/UG

UTH4213T [6]

6–350

1/2 in. Hex

14–2

Steel

Series A-L

ACPL

 9R

200

5

OH

UTH5203T OBS

6–350

1/2 in. Hex

14–2

Steel

Series A-L

ACPL

 8R

200

5

OH/UG

UTH5213T [6]

6–350

1/2 in. Hex

14–2

Steel

Series A-L

ACPL

 9R

320

4

OH/UG

UTH4330T [14]

Studs Only

3/8 in. dia. studs

14–1/0

Steel

Series A-L

ACPL

11R

320

4

OH/UG

1008068

Dual 6-350

5/16 in. Allen

14-1/0

Steel

Series A-L

ACPL [13]

34.5x16.44x6.5 inches

200

5

OH/UG

1008801

6-350

1/2 in. Hex 5/16 Allen

14-2

Steel

Series A

ACP [13]

9R

320

4

OH/UG

1009788A

3/8 in. Studs

9/16 in. Hex

None

Steel

Series A-L

ACPL [13]

34.5x13x5 inches

320

4

OH/UG

UATH4330U

3/8 in. Studs

9/16 in. Hex

14-1/0

Aluminum

Series A-L

ACPL [13]

11R

320

4

OH/UG

UTH43369T

Line 4-600 Load Dual 6-350

Line 1/2 in. Allen Load 5/16 in. Allen

14-1/0

Steel

Series A-L

ACPL

11R

Ringless Type, 3Ø4W 600 Vac Max., With Lever Bypass and Jaw Release

200

7

OH/UG

UTH7213T [6]

6–350

1/2 in. Hex

14–2

Steel

Series A-L

ACPL

 9R

320

7

OH

UTH7300T [14]

Studs Only

3/8 in. dia. studs

14–1/0

Steel

Series A-L

ACPL

10R

200 A

7

OH/UG

UH7213C

6-350

1/2 in. Hex 5/16 Allen

None

Steel

Series A

ACP [13]

19x13x5 inches

Ringless Type, 3Ø4W 600 Vac Max., Bolt-On Socket Without Bypass

400

7

OH/UG

UK7T  OBS[14]

Studs Only

1/2 in.–20
dia. studs

1/2 in.–20
dia. studs

Steel

Series A-L

ACPL

12R

400

7

OH/UG

UAK7T OBS[14]

Studs Only

1/2 in.–20
dia. studs

1/2 in.–20
dia. studs

Aluminum

Series A-L

ACPLA

12R

Ring Type, 1Ø3W 600 Vac Max., Without Bypass or Jaw Release

125

4

OH/UG

URTRS101B [6]

8–2/0

Slotted

14–2

Steel

Series A

ACP

1R

200

4

OH/UG

URTRS213B [6]

1/0–350

1/2 in. Hex

14–2

Steel

Series A

ACP

5R

125

5

OH

URS101BCR

8-2/0

Slotted

14-2

Steel

Series A

ACP

1R

200

5

OH

URS202BCR

8-250

1/2 in. Hex 5/16 Allen

14-2

Steel

Series A

ACP

3R

OBS – This product is obsolete.

Footnotes

  1. Rating is continuous.
  2. Device requires approval from the serving utility, consult your nearest Schneider Electric sales office.
  3. For box dimensions, see Meter Socket Dimensions
  4. Order appropriate bolt-on hub or closing plate separately and install on TOP endwall.

  5. Device supplied with solid top endwall (without hub opening).

  6. When unit is installed for underground feed, the appropriate closing plate must be ordered separately and installed over hub opening in TOP endwall of device.

  7. Device supplied with closing plate ACP mounted on TOP endwall.
  8. Device supplied with two closing plates ACP mounted in TOP endwall.

  9. Device supplied with solid top endwall (without hub opening).[5]
  10. Factory wiring is #12 CU. Field wiring can be up to #10.
  11. Device supplied with 1-1/4 in. bolt-on hub (Cat. No. A125) mounted on TOP endwall.

  12. Contains “Duquesne Light Co.” approved label.

  13. Device supplied with closing plate ACP mounted on TOP endwall.[10]
  14. Order lugs separately, see Meter Socket Accessories

Was this helpful?