1 Phase Main Devices
Class 4161 / Refer to Catalog 4100CT0701
1 phase, 3 wire 120/240 Vac EZ Meter-Pak™ Meter Centers
1 phase, Indoor/Rainproof, UL Listed
1200 A Main CB/Fusible Switch Devices come Standard with 2-STEP Removable Service Entrance Endwalls
Select EZM meter center short circuit current rating from UL Listed Meter Center Short Circuit Current Ratings (SCCR). Using this table as a reference, make the following selections:
-
Select EZM 1Ø main device from Main Devices, Overhead/Underground Feed or Main Devices, Underground Feed Only, with an equal or higher short circuit rating than the application.
-
Select EZM 1Ø branch units from Branch Units—1Ø Incoming and 1Ø Outgoing , Branch Units—225 A Maximum Commercial or Branch Units—400 A Maximum Commercial .
-
Select proper 2P type QO, QO-VH, QOH, QBP-TM, QDP-TM, QGP-TM or QJP-TM branch circuit breakers for use as tenant mains in branch unit from 125 A Max. EZM Branch Unit Tenant Circuit Breakers and 225 A Max. EZM Branch Unit Tenant Circuit Breakers.
-
Select accessories as required from Accessories.
-
Dimensions; see Main Devices Dimensions (in.) and Three Phase Branch Devices Dimensions (in.).
Select Main Devices—NEMA 3R Construction
1Ø Main Devices
Ampere |
Service |
Horizontal Cross |
Cat. No. [1] |
Width |
Factory-Installed
Line Side Lug |
||
---|---|---|---|---|---|---|---|
EZM11200FST |
Main Circuit Breaker (1Ø Incoming and 1Ø Outgoing) |
||||||
65 kA |
100 kA |
||||||
400 |
OH/UG |
400 A, Al |
— |
18.66 |
(1) 1–600 or (2) 1–250 |
||
600 |
OH/UG |
600 A, Al |
— |
18.66 |
(3) 3/0–500 |
||
800 |
OH/UG |
800 A, Al |
— |
18.66 |
(3) 3/0–500 |
||
1000 |
OH/UG |
1200 A, Cu |
— |
18.66 |
(3) 3/0–500 |
||
1200 |
OH |
1200 A, Al |
23.69 |
(4) 3/0-500 |
|||
1200 |
UG |
1200 A, Al |
— |
23.69 |
(4) 3/0–500 |
||
1600 |
UG |
1200 A, Al/Cu |
22.48 |
6 (Order Lugs Separately) |
|||
1600 |
OH/UG |
1200 A, Al/Cu |
30.19 |
(6) 1/0–750 or (12) 1/0–250 |
|||
2000 |
OH/UG |
1200 A, Al/Cu |
— |
30.19 |
(6) 1/0–750 or (12) 1/0–250 |
||
2000 |
UG |
1200 A, Al/Cu |
— |
30.19 |
6 (Order Lugs Separately) |
||
Main Fusible Switches (1Ø Incoming and 1Ø Outgoing) Requires 300 Vac Class T Fuses (Order Separately) |
|||||||
400 |
OH/UG |
400 A, Al |
— |
18.66 |
(1) 1–600 or (2) 1–250 |
||
600 |
OH/UG |
600 A, Al |
— |
18.50 |
(3) 3/0–500 |
||
600 |
UG |
600 A, Al |
— |
20.46 |
2 (Order Lugs Separately) |
||
800 |
OH/UG |
800 A, Al |
— |
18.50 |
(3) 3/0–500 |
||
800 |
UG |
800 A, Al |
— |
20.46 |
2 (Order Lugs Separately) |
||
1200 |
OH |
1200 A, Al |
— |
23.69 |
(4) 3/0–500 |
||
1200 |
UG |
1200 A, Al |
— |
23.69 |
(4) 3/0–500 |
||
Main Lug Terminal Boxes (1Ø Incoming and 1Ø Outgoing) |
|||||||
225 |
OH/UG |
800 A, Al |
— |
11.66 |
(1) 4–300 |
||
400 |
OH/UG |
800 A, Al |
— |
17.15 |
(2) 3/0–500 |
||
600 |
OH/UG |
800 A, Al |
— |
17.15 |
(2) 1/0–750 or (4) 1/0–300 |
||
800 |
OH/UG |
800 A, Al |
— |
18.66 |
(4) 3/0–500 |
||
800 |
OH/UG |
800 A, Cu |
— |
24.08 |
(4) 3/0–500 |
||
1600 |
OH/UG |
1200 A, Al/Cu |
— |
22.48 |
(6) 1/0-600 or (12) 1/0-300 |
||
2000 |
OH/UG |
1200 A, Al/Cu |
— |
30.19 |
6 (Order Lugs Separately) |
||
Main Circuit Breaker (1Ø Incoming and 1Ø Outgoing) with Energy Reduction Maintenance (ERMS) |
|||||||
1200 |
UG |
1200 A, Al |
26.39 |
(4) 3/0–500 |
|||
1200 |
OH |
1200 A, Cu |
— |
23.69 |
(4) 3/0–500 |
||
1600 |
OH/UG |
1200 A, Cu |
— |
30.19 |
(6) 1/0–750 or (12) 1/0–250 |
||
1600 |
UG |
1200 A, Al |
30.19 |
6 (Order Lugs Separately) |
|||
2000 |
OH/UG |
1200 A, Cu |
— |
30.19 |
(6) 1/0-750 or (12) 1/0-250 |
||
2000 |
UG |
1200 A, Al |
— |
30.19 |
6 (Order Lugs Separately) |
1Ø Main Devices, EUSERC
Ampere |
Service |
Horizontal Cross Bus Rating and Bus Bar Material |
Cat. No. |
Width |
Factory-Installed Lug Landings for use with Crimp-Type Lugs (2-Hole Mounting) Qty. per Phase and Neutral, except non-EUSERC. [8] |
||
---|---|---|---|---|---|---|---|
EZM11200GCBE |
Main Circuit Breakers (1Ø Incoming and 1Ø Outgoing)[8] |
||||||
65 kA |
100 kA |
||||||
400 |
UG |
400 A, Al |
— |
20.46 |
1 (Order Lugs Separately) |
||
600 |
UG |
600 A, Al |
— |
26.19 |
2 (Order Lugs Separately) |
||
800 |
UG |
800 A, Al |
— |
26.19 |
2 (Order Lugs Separately) |
||
1000 |
UG |
1200 A, Cu |
— |
34.19 |
2 (Order Lugs Separately) |
||
1200 |
UG |
1200 A, Al |
32.39 |
3 (Order Lugs Separately) |
|||
Main Fusible Switches (1Ø Incoming and 1Ø Outgoing) [8] Requires 300 Vac Class T Fuses (Order Separately) |
|||||||
400 |
UG |
400 A, Al |
— |
20.46 |
1 (Order Lugs Separately) |
||
600 |
UG |
600 A, Al |
— |
18.36 |
2 (Order Lugs Separately) |
||
1200 |
UG |
1200 A, Al |
— |
32.39 |
3 (Order Lugs Separately) |
||
Main Lug Terminal Boxes (1Ø Incoming and 1Ø Outgoing) |
|||||||
400 |
UG |
800 A, Al |
— |
17.16 |
1 (Order Lugs Separately) |
||
800 |
UG |
800 A, Al |
— |
25.16 |
2 (Order Lugs Separately) |
||
1200 |
UG |
1200 A, Al/Cu |
— |
33.16 |
3 (Order Lugs Separately) |
||
Main Circuit Breaker (1Ø Incoming and 1Ø Outgoing) with Energy Reduction Maintenance Switch (ERMS) |
|||||||
1200 |
UG |
1200 A, Al |
32.39 |
3 (Order Lugs Separately) |