Bonded Neutral Safety Switches
Refer to Safety Switches Online
240 Volt Single-Throw Fusible Switches
240 Volt Single-Throw Fusible Safety Switches
|
Ampere |
Type 1 |
Type 3R |
Equipment Ground Kit |
Type 12 |
Type 4X |
Class R |
Line Side |
Horsepower Ratings |
||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Std (Fast Acting One-Time Fuses) |
Max (Dual Element Time-Delay Fuses) |
250 Vdc |
||||||||||
|
1Ø |
3Ø |
1Ø |
3Ø |
|||||||||
|
3 Wire (2 Blade and Fuseholder, 1 neutral) –240 Vac 250 Vdc |
||||||||||||
|
30 |
Factory Included |
1-1/2 |
3 |
3 |
7-1/2 |
5 |
||||||
|
60 |
Factory Included |
3 |
7-1/2 |
10 |
15 |
10 |
||||||
|
100 |
Factory Included |
7-1/2 |
15 |
15 |
30 |
20 |
||||||
|
200 |
VH224BDSGL |
Factory Included |
15 |
25 |
— |
60 |
40 |
|||||
|
400 |
CH225NDS |
— |
50 |
— |
125 |
50 |
||||||
|
600 |
CH226NDS |
— |
75 |
— |
200 |
50 |
||||||
|
800 |
CH227N |
CH227NR |
CH227NAWK |
— |
— |
50 |
— |
— |
— |
50 |
||
|
1200 |
CH228N |
CH228NR |
CH228NAWK |
— |
— |
50 |
— |
— |
— |
50 |
||
|
4 Wire (3 Blade and Fuseholder, 1 neutral) –240 Vac 250 Vdc |
||||||||||||
|
30 |
Factory Included |
1-1/2 |
3 |
3 |
7-1/2 |
5 |
||||||
|
60 |
Factory Included |
3 |
7-1/2 |
10 |
15 |
10 |
||||||
|
100 |
Factory Included |
7-1/2 |
15 |
15 |
30 |
20 |
||||||
|
200 |
Factory Included |
15 |
25 |
— |
60 |
40 |
||||||
|
400 |
— |
50 |
— |
125 |
50 |
|||||||
|
600 |
— |
75 |
— |
200 |
50 |
|||||||
|
800 |
CH327N |
CH327NR |
CH327NAWK |
— |
— |
50 |
— |
— |
— |
50 |
||
|
1200 |
CH328N |
CH328NR |
CH328NAWK |
— |
— |
50 |
— |
— |
— |
50 |
||
600 Volt Single-Throw Fusible Switches
600 Volt Single-Throw Fusible Safety Switches
|
Ampere |
Type 1 |
Type 3R |
Equipment Ground Kit |
Type 12 |
Type 4X |
Class R Fuse Kits |
Line Side Barriers |
Horsepower Ratings |
||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Std (Fast acting one-time fuses) |
Max (Dual element time-delay fuses) |
600 Vdc |
||||||||||
|
1Ø |
3Ø |
1Ø |
3Ø |
|||||||||
|
4 Wire (3 Blade and Fuseholder, 1 neutral) –600 Vac 600Vdc |
||||||||||||
|
30 |
Factory Included |
5 |
15 |
7-1/2 |
20 |
15 |
||||||
|
60 |
Factory Included |
15 |
30 |
15 |
50 |
30 |
||||||
|
100 |
Factory Included |
25 |
60 |
30 |
100 |
50 |
||||||
|
200 |
Factory Included |
50 |
125 |
60 |
150 |
50 |
||||||
|
400 |
CH365NDS |
100 |
250 |
125 |
350 |
50 |
||||||
|
600 |
CH366NDS |
150 |
400 |
200 |
500 |
50 |
||||||
|
800 |
CH367N |
CH367NR |
CH367NAWK |
— |
— |
200 |
500 |
250 |
500 |
50 |
||
|
1200 |
CH368N |
CH368NR |
CH368NAWK |
— |
— |
200 |
500 |
250 |
500 |
50 |
||