990-91377H-001

Efficiency

NOTE: The efficiency values are measured at the output terminals/busbars of the UPS.
200 kW Normal operation ECO mode
Voltage (V) 380 400 415 440 380 400 415 440
25% load

96.5%

96.6%

96.5%

96.5%

98.9%

98.8%

98.9%

98.9%

50% load

97.0%

97.1%

97.1%

97.1%

99.3%

99.3%

99.3%

99.2%

75% load

96.9%

97.0%

97.1%

97.2%

99.3%

99.4%

99.4%

99.4%

100% load

96.5%

96.7%

96.9%

97.0%

99.4%

99.4%

99.4%

99.4%

200 kW eConversion Battery operation
Voltage (V) 380 400 415 440 380 400 415 440
25% load

98.4%

98.4%

98.3%

98.3%

96.0%

96.0%

96.0%

95.5%

50% load

99.0%

99.0%

99.0%

99.0%

96.6%

96.6%

96.6%

96.3%

75% load

99.2%

99.2%

99.2%

99.2%

96.6%

96.6%

96.6%

96.5%

100% load

99.3%

99.3%

99.3%

99.3%

96.4%

96.4%

96.4%

96.4%

250 kW Normal operation ECO mode
Voltage (V) 380 400 415 440 380 400 415 440
25% load

96.6%

96.6%

96.6%

96.5%

98.9%

98.9%

98.9%

98.9%

50% load

97.0%

97.1%

97.1%

97.2%

99.3%

99.3%

99.3%

99.3%

75% load

96.9%

97.0%

97.1%

97.2%

99.4%

99.4%

99.4%

99.4%

100% load

96.5%

96.7%

96.8%

97.0%

99.4%

99.4%

99.4%

99.4%

250 kW eConversion Battery operation
Voltage (V) 380 400 415 440 380 400 415 440
25% load

98.4%

98.4%

98.3%

98.3%

96.1%

96.1%

96.1%

95.7%

50% load

99.0%

99.0%

99.0%

99.0%

96.6%

96.6%

96.6%

96.4%

75% load

99.2%

99.2%

99.2%

99.2%

96.6%

96.6%

96.6%

96.5%

100% load

99.3%

99.3%

99.3%

99.3%

96.4%

96.4%

96.4%

96.4%

300 kW Normal operation ECO mode
Voltage (V) 380 400 415 440 380 400 415 440
25% load

96.6%

96.6%

96.6%

96.5%

98.9%

99.0%

98.9%

98.9%

50% load

97.0%

97.1%

97.1%

97.2%

99.3%

99.3%

99.3%

99.3%

75% load

96.9%

97.0%

97.1%

97.2%

99.4%

99.4%

99.4%

99.4%

100% load

96.5%

96.7%

96.8%

97.0%

99.4%

99.4%

99.4%

99.4%

300 kW eConversion Battery operation
Voltage (V) 380 400 415 440 380 400 415 440
25% load

98.4%

98.4%

98.3%

98.3%

96.2%

96.2%

96.2%

95.8%

50% load

99.0%

99.0%

99.0%

99.0%

96.7%

96.7%

96.7%

96.4%

75% load

99.2%

99.2%

99.2%

99.2%

96.6%

96.6%

96.6%

96.5%

100% load

99.3%

99.3%

99.3%

99.3%

96.4%

96.4%

96.4%

96.4%

350 kW Normal operation ECO mode
Voltage (V) 380 400 415 440 380 400 415 440
25% load

96.6%

96.6%

96.6%

96.5%

99.0%

99.0%

99.0%

99.0%

50% load

97.0%

97.1%

97.1%

97.1%

99.3%

99.3%

99.3%

99.3%

75% load

96.8%

97.0%

97.1%

97.2%

99.3%

99.4%

99.4%

99.4%

100% load

96.5%

96.7%

96.8%

97.0%

99.4%

99.4%

99.4%

99.4%

350 kW eConversion Battery operation
Voltage (V) 380 400 415 440 380 400 415 440
25% load

98.4%

98.4%

98.4%

98.3%

96.3%

96.3%

96.3%

95.9%

50% load

99.1%

99.0%

99.0%

99.0%

96.7%

96.7%

96.7%

96.5%

75% load

99.2%

99.2%

99.2%

99.2%

96.6%

96.6%

96.6%

96.5%

100% load

99.3%

99.3%

99.3%

99.3%

96.4%

96.4%

96.4%

96.4%

400 kW Normal operation ECO mode
Voltage (V) 380 400 415 440 380 400 415 440
25% load

96.6%

96.6%

96.6%

96.5%

99.0%

99.0%

99.0%

99.0%

50% load

97.0%

97.1%

97.1%

97.1%

99.3%

99.3%

99.3%

99.3%

75% load

96.8%

97.0%

97.1%

97.2%

99.3%

99.4%

99.4%

99.4%

100% load

96.5%

96.7%

96.8%

97.0%

99.4%

99.4%

99.4%

99.4%

400 kW eConversion Battery operation
Voltage (V) 380 400 415 440 380 400 415 440
25% load

98.4%

98.4%

98.4%

98.3%

96.3%

96.3%

96.3%

95.9%

50% load

99.1%

99.0%

99.0%

99.0%

96.7%

96.7%

96.7%

96.5%

75% load

99.2%

99.2%

99.2%

99.2%

96.6%

96.6%

96.6%

96.5%

100% load

99.3%

99.3%

99.3%

99.3%

96.4%

96.4%

96.4%

96.4%

450 kW Normal operation ECO mode
Voltage (V) 380 400 415 440 380 400 415 440
25% load

96.6%

96.6%

96.6%

96.5%

99.0%

99.0%

99.0%

99.0%

50% load

97.0%

97.1%

97.1%

97.1%

99.3%

99.3%

99.3%

99.3%

75% load

96.8%

96.9%

97.0%

97.1%

99.3%

99.3%

99.4%

99.4%

100% load

96.4%

96.6%

96.8%

96.9%

99.3%

99.4%

99.4%

99.4%

450 kW eConversion Battery operation
Voltage (V) 380 400 415 440 380 400 415 440
25% load

98.5%

98.4%

98.4%

98.3%

96.3%

96.3%

96.3%

96.0%

50% load

99.1%

99.0%

99.0%

99.0%

96.7%

96.7%

96.7%

96.5%

75% load

99.2%

99.2%

99.2%

99.2%

96.6%

96.6%

96.6%

96.5%

100% load

99.3%

99.3%

99.3%

99.3%

96.4%

96.4%

96.4%

96.4%

500 kW Normal operation ECO mode
Voltage (V) 380 400 415 440 380 400 415 440
25% load

96.6%

96.6%

96.6%

96.5%

99.0%

99.0%

99.0%

99.0%

50% load

97.0%

97.1%

97.1%

97.1%

99.3%

99.3%

99.3%

99.3%

75% load

96.8%

96.9%

97.0%

97.1%

99.3%

99.3%

99.4%

99.4%

100% load

96.4%

96.6%

96.8%

96.9%

99.3%

99.4%

99.4%

99.4%

500 kW eConversion Battery operation
Voltage (V) 380 400 415 440 380 400 415 440
25% load

98.5%

98.4%

98.4%

98.3%

96.3%

96.3%

96.3%

96.0%

50% load

99.1%

99.0%

99.0%

99.0%

96.7%

96.7%

96.7%

96.5%

75% load

99.2%

99.2%

99.2%

99.2%

96.6%

96.6%

96.6%

96.5%

100% load

99.3%

99.3%

99.3%

99.3%

96.4%

96.4%

96.4%

96.4%