Enclosed AC Drives and Soft Starters

Overview of S-Flex™ and Altistart™ Enclosed 22 / Enclosed 480

Type of Motor Control

Adjustable Speed Drives Commercial HVAC & Retrofits

Soft Starters Commercial

North America Enclosed
Soft Starters

Key Application/Market Segment

  • Pumps

  • Fans

  • Scroll Compressors

  • Pumps

  • Fans

  • Conveyors

  • Centrifuges

  • Agitators

  • Mixers

  • Grinders

  • Crushers

Packaged Products S-Flex (Altivar™ 212) Altistart Enclosed 22 Altistart Enclosed 480
 

Integrated controls protected within enclosures, optimized with disconnect means, circuit breakers, push buttons, selector switches, control logic, communication and miscellaneous options designed to meet application requirements.

Distribution voltage ranges for 50/60 Hz line supply

208 Vac, 240 Vac, 480 Vac

208 Vac, 230 Vac, 460 Vac, 575 Vac

208 Vac, 240 Vac, 480 Vac, 690 Vac

Horsepower ratings for three-phase motors

Variable torque

30–40 hp, 208/230 V

1–100 hp, 460 V

Type 1 and Type 12:

3–150 hp, 208 V

5–200 hp, 230 V

10–400 hp, 460 V

15–500 hp, 575 V

Type 3R or 50°C Rated:

3–125 hp, 208 V

5–150 hp, 230 V

10–400 hp, 460 V

15–500 hp, 575 V

Type 1, Type 12, and Type 3R:
3–200 hp, 208 V
5–250 hp, 230 V
10–500 hp, 480 V
15–600 hp, 575 V
Configurable options

Configurable products:

Drive with isolation/bypass

Non-bypass

Drive input disconnect switch

Line contactor

Communication options

Basic shunt tip

Full featured shunt trip

non-reversing isolation

Reversion isolation

Integral Full Voltage Bypass

Customizable products:
Non-reversing
Reversing
Shunt Trip
Extensive options
Enclosure ratings

Type 1 general purpose

Type 12 industrial use (Dust-Tight/Drip-Tight)

Type 3R outdoor use

Type 1 general purpose

Type 12 industrial use (Dust-Tight/Drip-Tight)

Type 3R outdoor use

Type 1 general purpose
Type 12 dust/drip proof
Type 3R outdoor service entrance
Communication
  • Modbus RJ45 (included as standard)

  • BACnet (embedded)

  • LonWorks (option card)

  • Metasys N2 (embedded)

  • APOGEE FLN (P1) (embedded)

  • Modbus (embedded)

  • Modbus (embedded)

  • Modbus TCP

  • EtherNet/IP

  • CANopen

  • PROFINET

  • PROFIBUS DP

Standards and Certifications

UL 508C, Seismic qualification ICC ES AC156 acceptance test protocol

Service Entrance Rating, UL Listed per UL 508 under category NKJH, Conforms to applicable NEMA ICS, NFPA, and IEC standards,

Manufactured under ISO9001 standards,

Factory modification E10 provides Canadian cUL certification per C22.2, No.14, Seismic qualification

UL 508, cUL/CSA, Seismic qualification ICC ES AC156 acceptance test protocaol, ABS

Overview of Altivar™ 680/980 Process, and 660/960 Process

 

North America Drive Systems

Key Applications and Market Segment
  • Water Waste Water

  • Regenerative Applications

  • Oil and Gas

  • Mining, Minerals, and Metals

  • Food and Beverage

  • Water Waste Water

  • Regenerative Applications

  • Oil and Gas

  • Mining, Minerals, and Metals

  • Food and Beverage

 

Altivar 680/980 Process Drives

Altivar 660/960 Process Drives

 
Brief Description

The world’s first three-level low harmonic drive, Altivar 680/980 drive solutions are designed for pumping or mechanical movement applications where harmonic mitigation and overall size is a priority.

The ATV680/980 has embedded, industry-leading harmonic mitigation technology, which results in THDi levels of 2.3%. With its small footprint and capability to be customized, the ATV680/980 is a very flexible low harmonic solution.

The ATV680/980 is a more efficient, more compact, and higher performing active rectification drive than any of our competitors by the integration of a common mode suppressing filter, and unique active filter resonance control.

The ATV680 is capable of 120% regeneration, while the ATV980 is capable of 180% of nameplate current.

The Altivar 660 Process System provides a wide range of fully tested and ready to connect drive solution. Starting from a compact pre engineered system to a fully engineered complex solution.

Special Features

Industry Leading Harmonic Mitigation: 2.3% THDi


Common Mode Voltage Suppression


Reduction of Bearing Currents


Generator Supply Capability

Compact design to save space


Dynamic QR Codes


50° C option available


Pump curves embedded


Multiple options available


Process control embedded
Embedded web server

Enclosure Ratings

UL Type 12

UL Type 1, UL Type 12, UL Type 3R

Power Range

125–900 hp, Normal Duty (ND)

 

208/340 V

460 V

Type 1

1–60 hp

1–900 hp, ND

Type 12

1–60 hp

1–900 hp, ND

Type 3R

1–60 hp

1–125 hp, ND

Distribution voltage ranges for 50/60 Hz line supply

480 Vac

208/240 Vac, 480 Vac

Standards / Certifications

UL/cUL Listed per UL508A, IEEE519 Compliant (harmonic filter required), Conforms to applicable NEMA ICS, NFPA, and IEC standards, Service entrance available, Manufactured under ISO 9001 standards.

UL/cUL Listed per UL508A, IEEE519 Compliant, Conforms to applicable NEMA ICS, NFPA, and IEC standards, Service entrance available, Manufactured under ISO 9001 standards.

Contact your local Schneider Electric Field Office for further information