Minimalwerte
Adresse |
Register |
Aktion |
Größe |
Typ |
Einheiten |
Beschreibung |
|
---|---|---|---|---|---|---|---|
PM3250 |
PM3255 |
||||||
Strom |
|||||||
0x6A51 |
27218 |
R |
R |
2 |
Float32 |
A |
Mindeststrom I1 |
0x6A53 |
27220 |
R |
R |
2 |
Float32 |
A |
Mindeststrom I2 |
0x6A55 |
27222 |
R |
R |
2 |
Float32 |
A |
Mindeststrom I3 |
0x6A57 |
27224 |
R |
R |
2 |
Float32 |
A |
Mindeststrom N |
0x6A5B |
27228 |
R |
R |
2 |
Float32 |
A |
Mindeststrom, Durchschnitt |
Spannung |
|||||||
0x6A65 |
27238 |
R |
R |
2 |
Float32 |
V |
Mindestspannung L1-L2 |
0x6A67 |
27240 |
R |
R |
2 |
Float32 |
V |
Mindestspannung L2-L3 |
0x6A69 |
27242 |
R |
R |
2 |
Float32 |
V |
Mindestspannung L3-L1 |
0x6A6B |
27244 |
R |
R |
2 |
Float32 |
V |
Mindestspannung L-L, Durchschnitt |
0x6A6D |
27246 |
R |
R |
2 |
Float32 |
V |
Mindestspannung L1-N |
0x6A6F |
27248 |
R |
R |
2 |
Float32 |
V |
Mindestspannung L2-N |
0x6A71 |
27250 |
R |
R |
2 |
Float32 |
V |
Mindestspannung L3-N |
0x6A75 |
27254 |
R |
R |
2 |
Float32 |
V |
Mindestspannung L-N, Durchschnitt |
Leistung |
|||||||
0x6A87 |
27272 |
R |
R |
2 |
Float32 |
kW |
Minimalwert Wirkleistung, Phase 1 |
0x6A89 |
27274 |
R |
R |
2 |
Float32 |
kW |
Minimalwert Wirkleistung, Phase 2 |
0x6A8B |
27276 |
R |
R |
2 |
Float32 |
kW |
Minimalwert Wirkleistung, Phase 3 |
0x6A8D |
27278 |
R |
R |
2 |
Float32 |
kW |
Minimalwert Gesamtwirkleistung |
0x6A8F |
27280 |
R |
R |
2 |
Float32 |
kVAR |
Minimalwert Blindleistung, Phase 1 |
0x6A91 |
27282 |
R |
R |
2 |
Float32 |
kVAR |
Minimalwert Blindleistung, Phase 2 |
0x6A93 |
27284 |
R |
R |
2 |
Float32 |
kVAR |
Minimalwert Blindleistung, Phase 3 |
0x6A95 |
27286 |
R |
R |
2 |
Float32 |
kVAR |
Minimalwert Gesamtblindleistung |
0x6A97 |
27288 |
R |
R |
2 |
Float32 |
kVA |
Minimalwert Scheinleistung, Phase 1 |
0x6A99 |
27290 |
R |
R |
2 |
Float32 |
kVA |
Minimalwert Scheinleistung, Phase 2 |
0x6A9B |
27292 |
R |
R |
2 |
Float32 |
kVA |
Minimalwert Scheinleistung, Phase 3 |
0x6A9D |
27294 |
R |
R |
2 |
Float32 |
kVA |
Minimalwert Gesamtscheinleistung |
Leistungsfaktor |
|||||||
0x6AA9 |
27306 |
R |
R |
2 |
4Q FP PF |
— |
Minimalwert Leistungsfaktor, Phase 1 |
0x6AAB |
27308 |
R |
R |
2 |
4Q FP PF |
— |
Minimalwert Leistungsfaktor, Phase 2 |
0x6AAD |
27310 |
R |
R |
2 |
4Q FP PF |
— |
Minimalwert Leistungsfaktor, Phase 3 |
0x6AAF |
27312 |
R |
R |
2 |
4Q FP PF |
— |
Minimalwert Gesamtleistungsfaktor |
Tangens Phi (Blindleistungsfaktor) |
|||||||
0x6AC7 |
27336 |
R |
R |
2 |
Float32 |
— |
Minimalwert Tangens Phi, Gesamtwert |
Klirrfaktor, Strom |
|||||||
0x6AC9 |
27338 |
R |
R |
2 |
Float32 |
% |
Minimalwert Klirrfaktor Strom I1 |
0x6ACB |
27340 |
R |
R |
2 |
Float32 |
% |
Minimalwert Klirrfaktor Strom I2 |
0x6ACD |
27342 |
R |
R |
2 |
Float32 |
% |
Minimalwert Klirrfaktor Strom I3 |
0x6ACF |
27344 |
R |
R |
2 |
Float32 |
% |
Minimalwert Klirrfaktor Strom N |
Klirrfaktor, Spannung |
|||||||
0x6ADF |
27360 |
R |
R |
2 |
Float32 |
% |
Minimalwert Klirrfaktor Spannung L1-L2 |
0x6AE1 |
27362 |
R |
R |
2 |
Float32 |
% |
Minimalwert Klirrfaktor Spannung L2-L3 |
0x6AE3 |
27364 |
R |
R |
2 |
Float32 |
% |
Minimalwert Klirrfaktor Spannung L3-L1 |
0x6AE5 |
27366 |
R |
R |
2 |
Float32 |
% |
Minimalwert Klirrfaktor Spannung L-L, Durchschnitt |
0x6AE7 |
27368 |
R |
R |
2 |
Float32 |
% |
Minimalwert Klirrfaktor Spannung L1-N |
0x6AE9 |
27370 |
R |
R |
2 |
Float32 |
% |
Minimalwert Klirrfaktor Spannung L2-N |
0x6AEB |
27372 |
R |
R |
2 |
Float32 |
% |
Minimalwert Klirrfaktor Spannung L3-N |
0x6AEF |
27376 |
R |
R |
2 |
Float32 |
% |
Minimalwert Klirrfaktor Spannung L-N, Durchschnitt |
Frequenz |
|||||||
0x6BDF |
27616 |
R |
R |
2 |
Float32 |
Hz |
Minimalwert, Frequenz |