Technical Data
Connected Thermostat Insert 2 A
Nominal voltage: |
AC 230 V ~, 50 Hz |
||
Maximum current rating |
Resistive load: |
2 A |
|
Inductive load: |
1 A |
||
Connecting terminals: |
Terminals for max. 2.5 mm² |
||
Neutral conductor: |
Required |
||
Ambient temperature: |
0 to 45 °C |
||
Relative humidity: |
max. 90% non-condensing |
||
Temperature accuracy: |
max. ±0.5 °C (across the range of 4 to 30 °C) |
||
Protection Class: |
II |
||
Working voltage: |
230 V |
||
Over-voltage category: |
III |
||
Rated impulse voltage: |
4 kV |
||
Pollution degree: |
2 |
||
CTI rating of insulation components: |
175 V |
||
Material group: |
IIIa (based on CTI value) |
||
Disconnection type: |
1.B |
Connected Thermostat Module, ZB
Standby: |
max 0.4 W |
|
Ambient operating temperature: |
0 to 45°C |
|
Relative humidity: |
max. 90% non-condensing |
|
Display: |
7x5 dot matrix, 3 additional LEDs |
|
Temperature measurement resolution: |
0.5 °C |
|
Operating frequency: |
2.405 GHz to 2.48 GHz |
|
Max. radio-frequency power transmitted: |
< 10 mW |
|
Communication protocol: |