I-Line Merchandised Panelboards
Refer to Catalog 2110CT9701
I-Line Panelboard
![]() HCJ Box Size: |
![]() HCP SU Box Size: |
TYPE HCJ 250 A max. branch circuit breaker BD, BG, BJ, QB,
QD, QG, QJ, HD, HG, |
TYPE HCP-SU 800 A max. main circuit breaker 600 A max. branch circuit breaker BD, BG, BJ, LA, LG, LJ, LL, LH, LR, ![]() |
Interiors, Boxes and Fronts
Total Circuit Breaker |
Mains Ampere Rating |
Interior Assembly (Less Branch |
Front [2] |
Box [3] |
Box Height (In.) |
||
---|---|---|---|---|---|---|---|
4 Piece Trim Without Door |
Trim With Door[3] |
Type 1 |
NEMA 3R/5/12 [4] (Includes Front) |
||||
Catalog Number |
Catalog |
Catalog |
Catalog |
Catalog |
|||
HCJ Main Lugs
Only |
|||||||
27 |
400 A |
HCM48T( ) |
HCM48T( )D |
48 |
|||
600 A |
|||||||
800 A |
|||||||
45 |
400 A |
HCM73T( ) |
HCM73T( )D |
73 |
|||
600 A |
|||||||
800 A |
|||||||
63 |
400 A |
||||||
600 A |
|||||||
800 A |
|||||||
99 |
400 A |
HCM91T( ) |
HCM91T( )D |
91 |
|||
600 A |
|||||||
800 A |
|||||||
HCJ Main Circuit Breaker [5] [6] |
|||||||
27 |
400 A |
HCM73T( ) |
HCM73T( )D |
73 |
|||
36 |
600 A |
||||||
800 A |
|||||||
45 |
400 A |
||||||
72 |
600 A |
HCM91T( ) |
HCM91T( )D |
91 |
|||
82 |
400 A |
||||||
72 |
800 A |
||||||
HCP-SU [7] Universal Single Row Main Lugs or Main Circuit Breaker [6] |
|||||||
54 |
800 |
HC2686T( )4P |
HC2686T( )HR[10] |
86 |
![]() TYPE HCP Box Size: |
![]() TYPE HCR-U Universal Mains Box Size: |
TYPE HCP 800 A max. branch circuit breaker BD, BG, BJ, QB,
QD, QG, QJ, HD, HG, HJ, HL, HR, |
TYPE HCR-U Universal Mains 1200 A max. branch circuit breaker BD, BG, BJ, QB,
QD, QG, QJ, HD, HG, HJ, HL, HR, |
(1200 A Interiors Include solid neutral, all others without solid neutral) [14]
Total Circuit Mtg. |
Mains Amp. Rating |
Max. No. of MJ, PL, RL Circuit |
Interior Assembly (Less Branch Circuit Breakers) |
Front [2] |
Box [15] |
Box Height (In.) |
|
---|---|---|---|---|---|---|---|
4 Piece Trim Without Door [16] |
Trim With Door |
||||||
Catalog |
Catalog Number |
Catalog Number |
Catalog |
||||
HCP Main Lugs Only—3-pole Suitable for use as service equipment when provided with a main circuit breaker and service barrier kit. |
|||||||
27 |
400 |
1PL |
HCW50T( ) |
HCW50T( )D |
50 |
||
600 |
|||||||
800 |
|||||||
1200 |
|||||||
45 |
400 |
2PL |
HCW59T( ) |
HCW59T( )D |
59 |
||
600 |
|||||||
800 |
|||||||
1200 |
|||||||
63 |
400 |
3PL |
HCW68T( ) |
HCW68T( )D |
68 |
||
600 |
|||||||
800 |
|||||||
1200 |
|||||||
99 |
400 |
5PL |
HCW86T( ) |
HCW86T( )D |
86 |
||
600 |
|||||||
800 |
|||||||
1200 |
|||||||
HCP Main Circuit Breaker[6]—Includes 3-pole Vertically mounted
main circuit breaker—Suitable for use as service equipment
with service barrier kit.[17]For main circuit breaker panel,
order plug-on I-Line type PG, PJ, PL, MG, or MJ circuit breakers from M-Frame 800 A, Basic Electronic Trip System Type ET 1.0[9] Factory-Sealed Trip Unit |
|||||||
36 |
600 |
2LC |
HCW68T( ) |
HCW68T( )D |
68 |
||
800 |
|||||||
72 |
600 |
4LC |
HCW86T( ) |
HCW86T( )D |
86 |
||
800 |
|||||||
HCR-U Universal Main Lugs or Main Circuit Breaker [13] —3-pole Suitable for use as service equipment when provided with a main circuit breaker and service barrier kit. For Main Lugs panel, order sub-feed lug kit catalog number S33930 and back-fed as main lugs. For Main Circuit Breaker panel, order plug-on I-Line
type PG, PJ, PL, RGC, RJC, or RLC [13] circuit breakers from PowerPacT P-frame 1200 A (600 Vac, 50/60 Hz) 3P Circuit Breaker
with Electronic Trip Unit |
|||||||
108 [18] |
1200 |
6PL or 3RLC |
HCR86T( )[19] |
HCR86T( )D |
86 |
Main Circuit Breaker Interiors —Standard Frame Types [6]
Main Circuit Breaker Ampacity |
Panelboard |
Factory Supplied |
---|---|---|
400 |
HCJ |
LAP36400MB |
600 |
HCJ, HCP |
MGP36600 or MGP36800 |
Type 3R/5R/12R Enclosures
Catalog Number |
Interior Type |
Dimensions (In.) |
||
---|---|---|---|---|
H |
W |
D |
||
HCP |
50 |
43.19 |
12.95 |
|
HCP |
59 |
43.19 |
12.95 |
|
HCP |
68 |
43.19 |
12.95 |
|
HCP |
86 |
43.19 |
12.95 |
|
HCR-U |
86 |
45.19 |
14.63 |
Standard Copper Bus Interiors
Type |
Main Ampacity |
---|---|
HCJ, HCP-SU |
800 |
HCP, HCR-U |
800 and Above |
note
Merchandised copper interiors are not available in all ampacities.
Circuit Breaker / Sub-feed Lug Kit Mounting Space Requirement
Type
of Circuit Breaker |
Maximum Ampacity | No. of Poles | Inch Mounting Requirements |
---|---|---|---|
BD, BG, BJ | 125 | 1 | 1.5 |
BD, BG, BJ | 2 | 3 | |
BD, BG, BJ | 3 | 4.5 | |
HD, HG | 150 | 2 | 3 |
HD, HG | 3 | 4.5 | |
HJ, HL, HR | 2, 3 | 4.5 | |
JD, JG, JJ, JL, JR, SL250 | 250 | 2, 3 | 4.5 |
LA, LH, SL400 | 400 | 6 | |
LG, LJ, LL, LR | 600 | 6 | |
I-Line Enable | N/A | 6 | |
MG, MJ, SL800, PGC, PJC, PLC | 800 | 9 | |
PG, PJ, PL, S33931 | 1200 | 9 | |
QB, QD, QG, QJ | 225 | 2 | 3 |
QB, QD, QG, QJ | 3 | 4.5 | |
RG, RJ, RL, RGC, RJC, RLC, S33930 | 1200 | 2, 3 | 15 |