I-Line Merchandised Panelboard Accessories
Refer to Catalog 2110CT9701
I-Line Merchandised Panelboard Accessories
I-Line Merchandised Panelboard Accessories
Description |
Catalog No. |
||
---|---|---|---|
Blank Filler Kit—1.5 in.[1] (One kit contains quantity of 3 blank fillers.) |
|||
Blank Filler Kit—4.5 in.[1] (One kit contains quantity of 5 blank fillers.) |
|||
Equipment Ground Bar Kits—HCJ, HCP, HCP-SU (single row), HCR-U |
|||
Blank Extensions (For replacement purposes) |
|||
1.5 in. for mounting on wide side of I-Line panelboard used with HNM1BL and HNM4BL as a filler plate on the wide side of the panel (HCP, HCP-SU and HCRU). Do not use with MicroLogic trip unit as this filler will cover the trip unit. |
HLW1BL |
||
4.5 in. for mounting on wide side of I-Line panelboard used with HNM1BL and HNM4BL as a filler plate on the wide side of the panel (HCP, HCP-SU and HCRU). Do not use with MicroLogic trip unit as this filler will cover the trip unit. |
HLW4BL |
||
1.5 in. for mounting on narrow side of I-Line panelboard used with HNM1BL and HNM4BL as a filler plate on the narrow side of the panel. Do not use with MicroLogic trip unit as this filler will cover the trip unit. |
HLN1BL |
||
4.5 in. for mounting on narrow side of I-Line panelboard used with HNM1BL and HNM4BL as a filler plate on the narrow side of the panel. Do not use with MicroLogic trip unit as this filler will cover the trip unit. |
HLN4BL |
||
4.5 in. for mounting on wide side of I-Line panelboard. For use with PowerPacT H and J circuit breakers mounted on the wide side of the panel so that electronic trip unit can be accessed. |
HLW4EBL |
||
4.5 in. for mounting on narrow side of I-Line panelboard. For use with PowerPacT H and J circuit breakers mounted on the narrow side of the panel so that electronic trip unit can be accessed. |
HLN4EBL |
UL Service Entrance Barriers Kits for I-Line Panelboards with Backfeed Main Circuit Breaker[2]
I-Line Panelboard Type |
Backfeed Main Circuit Breaker |
Catalog Number [3] |
---|---|---|
HCJ | H, J | |
HCP, HCP-SU | H, J | |
LA, LH, PowerPacT L | ||
M, P | ||
HCR | LA, LH, PowerPacT L | |
M | ||
P | ||
R | ||
note Barriers
are required by 2017 version of NFPA70—National Electric Code.
Both the 2017 UL67 and 2017 NFPA70 allow an exception for service
entrance panelboards with more than one disconnect.
|
Solid Neutral Lug Quantities and Sizes
Solid Neutral Assembly | Terminal Wire Range | Ampere Rating |
---|---|---|
HC2SN | (1) 6 - 300, (9) #1/0 - 14, (45) #4 - 14 | 225 A |
HC4SN[4] | (7) 6 - 350, (45) #4 - 14 | 400 A |
HC6SN[4] | (7) 6 - 350, (9) #1/0 - 14, (28) #4 - 14 | 600 A |
HC8SN[4] | (7) 6 - 350, (9) #1/0 - 14, (34) #4 - 14 | 800 A |
HCPSU8SN[5] | (4) 3/0 - 600, (7) 6 - 350, (9) #1/0 - 14, (34) #4 - 14, | 800 A |
HCW4SN[6] | (2) 4 - 600, (7) 6 - 350, (45) #4 - 14 | 400 A |
HCW6SN[6] | (4) 3/0 - 750, (7) 6 - 350, (9) #1/0 - 14, (34) #4 - 14 | 600 A |
HCW8SN[6] | (4) 3/0 - 750, (7) 6 - 350, (9) #1/0 - 14, (34) #4 - 14 | 800 A |
HCW12SN[6] | (4) 3/0 - 750, (7) 6 - 350, (9) #1/0 - 14, (34) #4 - 14 | 1200 A |
HCWM12SN[7] | (4) 3/0 - 750, (7) 6 - 350, (9) #1/0 - 14, (34) #4 - 14 | 1200 A |
HC6SNALCU | (7) 6 - 350, (9) #1/0 - 14, (28) #4 - 14 | 600 A |
HC8SNALCU | (7) 6 - 350, (9) #1/0 - 14, (34) #4 - 14 | 800 A |
HCPSU8SNALCU | (4) 3/0 - 600, (7) 6 - 350, (9) #1/0 - 14, (34) #4 - 14 | 800 A |
HCP4SNALCU | (2) 4 - 600, (7) 6 - 350, (45) #4 - 14 | 400 A |
HCP6SNALCU | (4) 3/0 - 750, (7) 6 - 350, (9) #1/0 - 14, (34) #4 - 14 | 600 A |
HCP8SNALCU | (4) 3/0 - 750, (7) 6 - 350, (9) #1/0 - 14, (34) #4 - 14 | 800 A |
HCP12SNALCU | (4) 3/0 - 750, (7) 6 - 350, (9) #1/0 - 14, (34) #4 - 14 | 1200 A |
HCR12SNALCU | (4) 3/0 - 750, (7) 6 - 350, (9) #1/0 - 14, (34) #4 - 14 | 1200 A |
HC6SNCU | (7) 6 - 350, (9) #1/0 - 14, (28) #4 - 14 | 600 A |
HC8SNCU | (7) 6 - 350, (9) #1/0 - 14, (28) #4 - 14 | 800 A |
HCPSU8SNCU | (4) 3/0 - 600, (7) 6 - 350, (9) #1/0 - 14, (28) #4 - 14, | 800 A |
HCW4SNCU | (2) 2 - 600, (7) 6 - 350, (9) #1/0 - 14, (28) #4 - 14 | 400 A |
HCW6SNCU | (2) 2 - 600, (7) 6 - 350, (9) #1/0 - 14, (28) #4 - 14 | 600 A |
HCW8SNCU | (4) 3/0 - 750, (7) 6 - 350, (9) #1/0 - 14, (28) #4 - 14 | 800 A |
HCP12SNCU | (4) 3/0 - 750, (7) 6 - 350, (9) #1/0 - 14, (28) #4 - 14 | 1200 A |
HCW12SNCU | (7) 6 - 350, (9) #1/0 - 14, (28) #4 - 14 | 1200 A |
HCR12SNCU | (4) 3/0 - 750, (7) 6 - 350, (9) #1/0 - 14, (28) #4 - 14 | 1200 A |
HCR2SNCTW | (7) 6 - 350, (9) #1/0 - 14, (34) #4 - 14 | 250 A |
HCR2SNCTWALCU | (7) 6 - 350, (9) #1/0 - 14, (34) #4 - 14 | 250 A |
HCR2SNCTWCU | (7) 6 - 350, (9) #1/0 - 14, (28) #4 - 14 | 250 A |
HCR12SNCTW[7] | (7) 6 - 350, (9) #1/0 - 14, (34) #4 - 14 | 1200 A |
HCR12SNCTWALCU | (7) 6 - 350, (9) #1/0 - 14, (34) #4 - 14 | 1200 A |
HCR12SNCTWCU | (7) 6 - 350, (9) #1/0 - 14, (28) #4 - 14 | 1200 A |
HCPSU2SNCTW | (7) 6 - 350, (9) #1/0 - 14, (34) #4 - 14 | 250 A |
HCPSU2SNCTWALCU | (7) 6 - 350, (9) #1/0 - 14, (34) #4 - 14 | 250 A |
HCPSU2SNCTWCU | (7) 6 - 350, (9) #1/0 - 14, (28) #4 - 14 | 250 A |
HCPSU8SNCW[5] | (7) 6 - 350, (9) #1/0 - 14, (28) #4 - 14 | 800 A |
HCPSU12SNCTWALCU | (7) 6 - 350, (9) #1/0 - 14, (28) #4 - 14 | 1200 A |
HCPSU12SNCTWCU | (7) 6 - 350, (9) #1/0 - 14, (28) #4 - 14 | 1200 A |
HCP16NALCU | (35) 350, (9) #1/0 - 14, (17) #4 - 14 | 800 A |
HCR24NALCU | (8) 750, (21) 350, (9) #1/0 - 14, (17) #4 - 14 | 1200 A |
HCPSU16NALCU | (8) 750, (21) 350, (9) #1/0 - 14, (17) #4 - 14 | 800 A |
Panelboard Adapter Kits
Crimp Lug Adapter Kits [8] |
I-Line Panelboard Type |
|
---|---|---|
HCJ |
HCP, HCR-U [9] |
|
400 A |
||
600 A |
||
800 A |
||
1200 A |
— |
Box Extensions
Catalog Number |
Interior Type |
Extension |
|
---|---|---|---|
HC2609DEX (F or S) |
HCP-SU |
9 in. |
|
HC3209EX (F or S) |
HCJ |
9 in. |
|
HC4212DEX (F or S) |
HCP |
12 in. |
|
HC4406DEX (F or S) |
HCR-U |
6 in. |
|
HC4412DEX (F or S) |
HCR-U |
12 in. |
The Drip Hoods listed below are intended for use on surface mounted HC boxes only. Select the appropriate Drip Hood based on Interior Type, Width, and Depth from the following table. The Drip Hoods are designed to fit on the outside of the boxes. The Drip Hood will increase the enclosure rating of the box from Type 1 to Type 2. Reference Instruction Bulletin 80043-401-03.
I-Line PanelBoard Drip Hood Kits
Catalog Number | Interior Type | Dimensions (In.) | |
---|---|---|---|
Width | Depth | ||
HCT2DH32D9 | HCJ | 32 | 9.5 |
HCT2DH42 | HCP | 42 | 9.5 |
HCT2DH26D9 | HCP-SU | 26 | 9.5 |
HCT2DH47 | HCP (L5)[10] | 47 | 9.5 |
HCT2DH56 | HCP (PL)[11] | 56 | 9.5 |
HCT2DH42D12 | HCP (DB)[12] | 42 | 12.5 |
HCT2DH44 | HCR-U | 44 | 9.5 |
HCT2DH49 | HCR-U (L5)[10] | 49 | 9.5 |
HCT2DH58 | HCR-U (PL)[11] | 58 | 9.5 |
HCT2DH44D12 | HCR-U (DB)[12] | 44 | 12.5 |
Sub-feed Lug Kits [13][14][15]
Ampere Rating |
Height |
Catalog Number |
Max. Short Circuit System Ratings RMS Symmetrical Amperes |
Protected by Circuit Breaker |
For Use in I-Line Panelboard Types |
|||
---|---|---|---|---|---|---|---|---|
In. |
(mm) |
240 Vac |
480 Vac |
600 Vac |
||||
250 A |
4.5 |
114 |
200,000 |
200,000 |
100,000 |
FA, FD, FG, FH, FJ, HD, HG, HJ, HL, HR, JD, JG, JJ, JL, JR, KI |
HCJ, HCP, HCP-SU, HCR-U |
|
400 A |
6 |
152 |
200,000 |
200,000 |
100,000 |
HD, HG, HJ, HL, HR, JD, JG, JJ, JL,
JR, LA, LH,, DG, DJ, DL, LG, LJ, LL, LR (“L” & “D”
FRAME |
HCP, HCP-SU, HCR-U (wide side only) |
|
800 A |
9 |
229 |
125,000 |
100,000 |
25,000 |
FA, FD, FG, FH, FJ, KA, KH, KC, KI, HD, HG, HJ, HL, HR, JD, JG, JJ, JL, JR, MA, MH, MX, MG, PG, MJ, PJ, PK, PL, DG, DJ, DL, LG, LJ, LL, LR |
HCJ, HCP, HCP-SU, HCR-U |
|
1200 A |
15 |
381 |
125,000 |
100,000 |
50,000 |
FA, FD, FG, FH, FJ, KA, KH, KC, KI, HD, HG, HJ, HL, HR, JD, JG, JJ, JL, JR, LA, LH, LC, LI, MA, MH, MX, NA, NC, NX, MG, PG, MJ, PJ, PK, PL, RG, RJ, RL, RK, DG, DJ, DL, LG, LJ, LL, LR |
HCR-U |
|
1200 A |
9 |
229 |
125,000 |
100,000 |
50,000 |
FA, FD, FG, FH, FJ, KA, KH, KC, KI, HD, HG, HJ, HL, HR, JD, JG, JJ, JL, JR, MG, PG, MJ, PJ, PK, PL, RG, RJ, RL, RK, DG, DJ, DL, LG, LJ, LL, LR |
HCP, HCP-SU, HCR-U |
|
noteS33930, S33931, SL1200P5, SL1200P6, SL1200P7, SL
Kits are rated 1200 A and may be applied to 1200 ampere loads when
installed into HCRU panelboards. However, when installed into HCP
and HCPSU panelboards they are only rated 800 amperes maximum due
to restricted wire bending space.
|
Sub-feed Lug kit terminal data
Catalog No. (Prefix) |
No. Poles |
Ampere Rating |
Standard Lug Wire Size [16] |
---|---|---|---|
SL100 |
3 |
100 |
#14–1/0 AWG Cu or #12–1/0 AWG Al |
SL250 |
3 |
250 |
(1) #4 AWG–300 kcmil |
SL400 |
3 |
400 |
(1) #1 AWG–600 kcmil or 2– #1 AWG–250 kcmil |
SL800M5 |
3 |
800 |
(3) #3/0 AWG–500 kcmil |
S33930 |
3 |
1200 |
(4) #3/0 AWG–600 kcmil |
SL1200P5 |
3 |
1200 |
(4) #3/0 AWG–500 kcmil |
SL1200P6 |
3 |
1200 |
(3) 350–600 kcmil |
SL1200P7 |
3 |
1200 |
(3) #3/0 AWG–750 kcmil |
S33931 |
3 |
1200 |
(4) #3/0–600 kcmil Al/Cu |