Harmony™ Level, Pump, Speed, Frequency, Temp. Control Relays, and NFC Control Relays
Refer to Catalog DIA5ED2160501EN
Harmony™ Level Control Relays and Pump Control Relays
Harmony level control relays control one or two levels with fill or empty function. The settings are protected by a sealable cover, control status is indicated by an LED, and they are DIN rail mountable. RM35LM is designed to control levels of conductive liquid, and RM35LV is designed to control levels of other materials.
Application examples for RM35LM: |
Application examples for RM35LV: |
|
|
Level Control Relays
Time Delay on Crossing the Threshold |
Function |
Output Relay |
Supply Voltage |
Measurement Ranges |
Catalog Number |
---|---|---|---|---|---|
0.1–5
seconds, |
Detection by resistive probes |
2 C/O, 5 A |
24–240 Vac/Vdc |
250–5 k |
|
5 k–100 k |
|||||
50 k–1 M |
|||||
Detection by discrete sensors |
1 C/O, 5 A |
— |
Electrode Holders
Description |
Material |
Catalog |
---|---|---|
Electrode for use up to 662°F (350°C) |
Stainless steel isolated by ceramic |
Pump Control Relay
Harmony pump control relay RM35BA10 can operate on a single-phase or 3-phase supply. It incorporates three functions in a signal unit:
|
|
|
It has two operating modes which are designed to control a pump via two external signal inputs (Y1 Y2). These two signals are controlled by volt-free contacts. Control inputs Y1 and Y2 can be connected to:
|
|
|
|
Pump Control Relay
Description |
Current Range Controlled |
Supply Voltage |
Output |
Catalog Number |
---|---|---|---|---|
Pump Control Relay |
1–10 A |
208–480 Vac, 3 phase |
1 C/O 5 A |
|
230, single-phase |
Approvals for Harmony Level Control and Pump Control Relays
File: E173076 |
File: 248382 |
CE 73/23/EEC and EMC 89/336/EEC |
GL, C-Tick, GOST, RoHS |
Approximate Dimensions (mm/in.)
Harmony™ Speed, Frequency, Temperature, and NFC Control Relays
Harmony speed control relay RM35SOMW monitors underspeed and overspeed conditions, with or without memory, with inhibition by an external contact. It operates with either N.O. or N.C. sensors. Adjustable time between impulses is 0.05 s to 10 min. Power-on inhibition time is adjustable from 0.6 to 60 s. Inhibition is controlled by an external contact. Settings are protected by a sealable cover, control status is indicated by an LED, and it is DIN rail mountable.
Speed Control Relay
Function |
Time Delay |
Measurement Input |
Supply |
Output |
Catalog Number |
---|---|---|---|---|---|
Underspeed |
0.05
s to |
3-wire PNP or NPN proximity sensor |
24–240 Vac/Vdc |
1 C/O |
|
Overspeed |
Namur type proximity sensor 0–30 V voltage Volt-free contact |
Harmony frequency control relay RM35HZ monitors its own supply voltage. Settings are protected by a sealable cover, control status is indicated by an LED, and it is DIN rail mountable.
Frequency Control Relay
Function |
Controlled |
Supply Voltage |
Output |
Catalog |
---|---|---|---|---|
Over frequency and
under frequency |
40–60
Hz (50 Hz) / |
120–277 Vac |
1 C/O
+ |
Harmony temperature control relays are designed for monitoring the temperature in elevator (lift) rooms, in compliance with directive EN81. For use with PT100 input (customer supplied). Features adjustable control, control status indicated by an LED, and is DIN rail mountable.
Temperature Control Relays
Function |
Supply Voltage |
Vac |
Output |
Catalog |
---|---|---|---|---|
Over temperature 93 to 114°F (34 to 46°C) |
24–240 |
— |
1 C/O |
Approvals for Harmony Speed, Frequency, and Temperature Control Relays
File: E173076 |
File: 248382 |
CE: 73/23/EEC and EMC 89/336/EEC |
GL, C-Tick, GOST, RoHS |
Approximate Dimensions (mm/in.)
NFC Contol Relays with Relay Output
Function |
Measurement Range |
Time Delay |
Output |
Reference |
Weight |
---|---|---|---|---|---|
|
208...480 A | Adjustable 0.1 s…60 min (Phase loss and Phase sequence instant trigger) |
2 CO 8 A (individually configurable)[1] |
0.125/0.276 |