Power Quality Meters — Selection
Power Quality Meter Selection
Features [1] | ION9000 | ION9000T | ION8650 | ION7400 | PM8000 | ||
---|---|---|---|---|---|---|---|
A | B | C | |||||
Inputs, outputs and control power |
|||||||
3-phase / single-phase | • / • | • / • | • / • | • / • | • / • | • / • | • / • |
Digital in and out / analog in and out | 46 / 24 | 46 / 24 | 16 / 4 | 16 / 4 | 16 / 4 | 36/24 | 36/24 |
Power supply options | AC / - | AC / - | AC/DC | AC/DC | AC/DC | AC/DC | AC/DC |
Power and energy measurements |
|||||||
Voltage, current, frequency, power factor | • | • | • | • | • | • | • |
Power / Demand | • | • | • / • | • / • | • / • | • / • | • / • |
Energy / time-of-use (energy per shift) | • / • | • / • | • / • | • / • | • / • | • / • | • / • |
IEC / ANSI energy accuracy class (% of reading) | 0.1 | 0.1 | 0.2(1) | 0.2(1) | 0.2(1) | 0.2 | 0.2 |
Loss compensation | • | • | • | • | • | • | - |
Power quality analysis |
|||||||
EN50160 compliance reporting / IEC 61000-4-30 Class A or S | • / A | • / A | • / A | • / S | - / - | • / A[2] | • / S |
Flicker measurement | • | • | • | • | - | •[3] | - |
Transient detection duration | 20 μs | 100 ns | 17 μs | - | - | - | - |
Sag and swell monitoring / disturbance direction detection | • / • | • / • | • / - | • / - | • / - | • / •[4] | • / • |
Harmonic distortion: total/ individual / inter | • / • / • | • / • / • | • / • / • | • / • / - | • / • / - | • / • / - | • / • / - |
Waveform capture | • | • | • | - | - | • | • |
Rapid Voltage Change | • | • | - | - | - | • | • |
On-board data and event logging |
|||||||
Trending / forecasting / billing | • / • / • | • / • / • | • / - / • | • / - / • | • / - / • | • / • / • | • / • / • |
Minimum and maximum | • / • | • / • | • | • | • | • | • |
Events and alarms with timestamps | • | • | • | • | • | • | • |
Timestamp resolution (seconds) | 0.001 | 0.001 | 0.001 | 0.001 | 0.001 | 0.001 | 0.001 |
Time sync: Network / GPS / IRIG-B / DCF77-B / PTP | • / • / • / • / • | • / • / • / • / • | • / • / • / - / - | • / • / • / - / - | • / • / • / - / - | • / • / • / - / - | • / • / • / - / - |
Setpoints, alarms and control |
|||||||
Log alarm conditions / call out on alarm | • / • | • / • | • / • | • / • | • / • | • / • | • / • |
Trigger data logging / waveform capture | • / • | • / • | • / • | • / - | • / - | • / • | • / • |
Trigger relay or digital output | • | • | • | • | • | • | • |
Special features |
|||||||
Custom programming | • | • | • | • | • | • | • |
Downloadable firmware | • | • | • | • | • | • | • |
Communications |
|||||||
Ports: |
|||||||
Ethernet: Copper / Fiber | 2 / 1 | 2 / 1 | • / • | • / • | • / • | 2 / 1 | 2 / 1 |
Ethernet-to-serial gateway | • | • | • | • | • | • | • |
Telephone modem | - | - | • | • | • | - | - |
Modem-to-serial gateway | - | - | • | • | • | - | - |
Verizon 4G LTE Cellular Modem[5] | - | - | • | • | • | - | - |
Infrared port | • | • | • | • / • | • / • | • | - |
RS485/RS232 | • / - | • / - | • / • | • / • | • / • | • / - | • / - |
Misc: Web server / Email / SNMP / XML | • / • / • / • | • / • / • / • | • / • / - / • | • / • / - / • | • / • / - / • | • / • / • / • | • / • / • / • |
Protocols: Modbus / DNP / MV-90 / DLMS | • / • / • / - | • / • / • / - | • / • / • / - | • / • / • / - | • / • / • / - | • / • / • / - | • / • / • / - |
Protocols: IEC61850 / Jbus / M-Bus / LON / BACnet | • / - / - / - / - | • / - / - / - / - | • / - / - / - / - | • / - / - / - / - | • / - / - / - / - | • / - / - / - / - | • / - / - / - / - |
note
-
The ION8650 is two times more accurate than the 0.2 IEC/ANSI accuracy classes according to the same conditions used to specify the 0.2 accuracy class.
-
ION8800, ION8650, ION8600, PM8000 also offer Modbus Master capabilities.