DOCA0105EN-09

About the Book

Document Scope

The aim of this document is to provide users, installers, and maintenance personnel with the technical information needed to operate the Modbus protocol on the following ranges of circuit breakers:

  • MasterPact MTZ1 circuit breakers from 630 to 1600 A

  • MasterPact MTZ2 circuit breakers from 800 to 4000 A

  • MasterPact MTZ3 circuit breakers from 4000 to 6300 A

Validity Note

This document is valid for MasterPact MTZ1/MTZ2/MTZ3 circuit breakers with a MicroLogic X control unit and connected:

  • either to an RS-485 serial line Modbus network using an IFM Modbus-SL interface for one circuit breaker.

  • or to an Ethernet network using:

    • an IFE Ethernet interface for one circuit breaker,

    • an IFE Ethernet switchboard server or,

    • an EIFE embedded Ethernet interface for one MasterPact MTZ drawout circuit breaker.

This document describes the registers and commands available for the IMU modules with the following firmware version:

IMU module

Part number

Firmware version

MicroLogic X control unit

-

≥ V004.101.000

IO module

LV434063

≥ V003.004.005

IFM interface

LV434000

≥ V003.001.012

IFE Ethernet interface

LV434001

≥ V004.007.000

LV434010

IFE Server

LV434002

≥ V003.016.000

LV434011

EIFE Ethernet interface

LV851001

≥ V004.007.000

You can update the firmware of the IMU modules by using the latest version of EcoStruxure Power Commission software.

NOTE: This guide also applies to MicroLogic Xi control units. A MicroLogic Xi control unit is a MicroLogic X control unit without Bluetooth Low Energy (BLE) communication.

The specific features of the MicroLogic Xi control units are described in the appendix in DOCA0102EN MasterPact MTZMicroLogic X Control Unit – User Guide.

Online Information

The information contained in this guide is likely to be updated at any time. Schneider Electric strongly recommends that you have the most recent and up-to-date version available on www.se.com/ww/en/download.

The technical characteristics of the devices described in this guide also appear online. To access the information online, go to the Schneider Electric home page at www.se.com.

Related Documents for IEC Devices

Title of documentation

Reference number

MasterPact MTZ1 – IEC Circuit Breakers and Switch-Disconnectors from 630 to 1600 A – User Guide

DOCA0100EN

MasterPact MTZ2/MTZ3 – IEC Circuit Breakers and Switch-Disconnectors from 800 to 6300 A – User Guide

DOCA0101EN

MasterPact MTZ – MicroLogic X Control Unit – User Guide

DOCA0102EN

ULP System (IEC Standard) – ULP (Universal Logic Plug) System – User Guide

DOCA0093EN

Enerlin'X IFE – Ethernet Switchboard Server – User Guide

DOCA0084EN

Enerlin'X IFE - Ethernet Interface for One IEC Circuit Breaker – User Guide

DOCA0142EN

Enerlin'X EIFE – Embedded Ethernet Interface for One MasterPact MTZ Drawout Circuit Breaker – User Guide

DOCA0106EN

Enerlin'X IO – Input/Output Application Module for One IEC Circuit Breaker – User Guide

DOCA0055EN

Enerlin'X IFEEthernet Interface for One Circuit Breaker – Instruction Sheet

QGH13473

Enerlin'X EIFE – Embedded Ethernet Interface for One MasterPact MTZ Drawout Circuit Breaker – Instruction Sheet

NVE23550

Enerlin'X IFMModbus-SL Interface for One Circuit Breaker – Instruction Sheet

NVE85393

Enerlin'X IO – Input/Output Application Module for One Circuit Breaker – Instruction Sheet

HRB49217

You can download these technical publications and other technical information from our website at www.se.com/ww/en/download.

Related Documents for UL Devices

Title of documentation

Reference number

MasterPact MTZ – MicroLogic X Control Unit – User Guide

DOCA0102EN

MasterPact MTZ1ULRated/ANSI Certified 800 to 1600 A Circuit Breakers and Switches – User Guide

0614IB1702EN

MasterPact MTZ2/MTZ3UL Rated/ANSI Certified 800 to 6000 A Circuit Breakers and Switches – User Guide

0614IB1701EN

ULP System (UL Standard) – ULP (Universal Logic Plug) System – User Guide

0602IB1503 (EN)

Enerlin'X IFE – Ethernet Switchboard Server – User Guide

1040IB1401 (EN)

Enerlin'X IFE – Ethernet Interface for One UL Circuit Breaker – User Guide

0602IB1801EN

Enerlin'X IO - Input/Output Application Module for One UL Circuit Breaker - User Guide

0613IB1317 (EN)

Enerlin'X IFEEthernet Interface for One Circuit Breaker – Instruction Sheet

QGH13473

Enerlin'X EIFE – Embedded Ethernet Interface for One MasterPact MTZ Drawout Circuit Breaker – Instruction Sheet

NVE23550

Enerlin'X IFMModbus-SL Interface for One Circuit Breaker – Instruction Sheet

NVE85393

Enerlin'X IO – Input/Output Application Module for One Circuit Breaker – Instruction Sheet

HRB49217

You can download these technical publications and other technical information from our website at www.se.com/ww/en/download.

QR Code is a registered trademark of DENSO WAVE INCORPORATED in Japan and other countries.

Was this helpful?