Coax Datasets (CoaxDataset_A & CoaxDataset_D)

As stated in the High-Level Architecture of the Geodatabase topic, one dataset contains components in a "proposed" or "design" state and is referred to as the "design dataset." The second dataset contains components that are constructed and in the field, representing the "as-built" assets in the final system of record.

Because all the fields are identical, each feature class is listed only once in these topics. However, in your implementation, the feature class is present in the geodatabase twice, using the naming conventions mentioned above.

RFAmplifier / RFAmplifier_D (RFAmplifierData)

DHFC object name: RFAmplifierData

GIS design table name: RFAmplifier_D

GIS built table name: RFAmplifier

GIS table type: FeatureClass

Geometry type: Point


Fields

Name

Alias

Type

Domain

Length

Precision

Nullable

Field Role

Data Transfer

AerialStructureId

AerialStructureId

Guid

FALSE

Required

BiDirectional

AmpNumber

Amp Number

SmallInteger

FALSE

Required

BiDirectional

CascadeNumber

Cascade Number

SmallInteger

FALSE

Required

ToGisOnly

CatalogId

CatalogId

Guid

FALSE

Required

BiDirectional

EsriId

OBJECTID

ObjectId

FALSE

Required

BiDirectional

FedFromComponentId

FedFromComponentId

Guid

FALSE

Required

BiDirectional

Flipped

Flipped

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

ForwardEqId

Forward EQ Id

String

50

FALSE

Required

BiDirectional

ForwardPadId

Forward Pad Id

String

50

FALSE

Required

BiDirectional

Geometry

SHAPE

Geometry

FALSE

Required

BiDirectional

HotDotPortNumber

Hot Dot Port Number

Integer

FALSE

Required

BiDirectional

InternalPowerMapping

Internal Power Mapping

String

50

FALSE

Required

BiDirectional

IsInMdu

Is In Mdu

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

IsLocked

Is Locked

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

ModelNumber

Model Number

String

50

FALSE

Required

BiDirectional

Name

Name

String

50

FALSE

Required

BiDirectional

NetworkId

NetworkId

Guid

FALSE

Required

BiDirectional

PoweringFedFromComponentId

PoweringFedFromComponentId

Guid

FALSE

Required

BiDirectional

ReturnEqId

Return EQ Id

String

50

FALSE

Required

BiDirectional

ReturnPadId

Return Pad Id

String

50

FALSE

Required

BiDirectional

SymbolRotation

Symbol Rotation

Double

38

8

FALSE

Required

BiDirectional

UGStructureId

UGStructureId

Guid

FALSE

Required

BiDirectional

Workflow_Status

Workflow Status

String

WorkflowState

FALSE

Required

BiDirectional

Amperage

Amperage

Double

38

8

TRUE

Optional

ToGisOnly

AmpType

Amplifier Type

String

AmplifierType

TRUE

Optional

ToGisOnly

Compensator

Compensator

String

255

TRUE

Optional

ToGisOnly

CreationUser

Creation User

String

50

TRUE

Optional

BiDirectional

DateCreated

Date Created

Date

TRUE

Optional

BiDirectional

DateModified

Date Modified

Date

TRUE

Optional

BiDirectional

DistanceToLastActive

Distance To Last Active

Double

38

8

TRUE

Optional

ToGisOnly

ForwardEqCID

Forward EQ Catalog Id

Guid

TRUE

Optional

ToGisOnly

ForwardInputHighLevel

Forward Input High Level

Double

38

8

TRUE

Optional

ToGisOnly

ForwardInputLowLevel

Forward Input Low Level

Double

38

8

TRUE

Optional

ToGisOnly

ForwardOutputHighLevel

Forward Output High Level

Double

38

8

TRUE

Optional

ToGisOnly

ForwardOutputLowLevel

Forward Output Low Level

Double

38

8

TRUE

Optional

ToGisOnly

ForwardPadCID

Forward Pad Catalog Id

Guid

TRUE

Optional

ToGisOnly

GainControlMode

Gain Control Mode

String

GainControlMode

TRUE

Optional

ToGisOnly

HubSite

HubSite

String

15

TRUE

Optional

ToGisOnly

InternalCouplerValue1

Internal Coupler Value 1

String

50

TRUE

Optional

ToGisOnly

InternalCouplerValue2

Internal Coupler Value 2

String

50

TRUE

Optional

ToGisOnly

InternalCouplerValue3

Internal Coupler Value 3

String

50

TRUE

Optional

ToGisOnly

IntPassive

Internal Passives

String

150

TRUE

Optional

ToGisOnly

InventoryNum

Inventory Number

String

50

TRUE

Optional

ToGisOnly

IsLeg1Terminated

Is Leg 1 Terminated

SmallInteger

EsriYesNoEnum

TRUE

Optional

ToGisOnly

LastUser

Last User

String

50

TRUE

Optional

BiDirectional

Manufacturer

Manufacturer

String

50

TRUE

Optional

ToGisOnly

Market

Market

String

255

TRUE

Optional

ToGisOnly

NetworkPath

Network Path

String

150

TRUE

Optional

ToGisOnly

NodeId

Node Id

Guid

TRUE

Optional

ToGisOnly

NodeLeg

Node Leg

String

50

TRUE

Optional

ToGisOnly

NodeName

Node Name

String

50

TRUE

Optional

ToGisOnly

OperationalForwardGain

Operational Forward Gain

Double

38

8

TRUE

Optional

ToGisOnly

OperationalReturnGain

Operational Return Gain

Double

38

8

TRUE

Optional

ToGisOnly

PowerMode

Power Mode

String

50

TRUE

Optional

ToGisOnly

PowerSupplyName

Power Supply Name

String

50

TRUE

Optional

ToGisOnly

ReturnEqCID

Return EQ Catalog Id

Guid

TRUE

Optional

ToGisOnly

ReturnPadCID

Return Pad Catalog Id

Guid

TRUE

Optional

ToGisOnly

ReverseInputHighLevel

Reverse Input High Level

Double

38

8

TRUE

Optional

ToGisOnly

ReverseInputLowLevel

Reverse Input Low Level

Double

38

8

TRUE

Optional

ToGisOnly

ReverseOutputHighLevel

Reverse Output High Level

Double

38

8

TRUE

Optional

ToGisOnly

ReverseOutputLowLevel

Reverse Output Low Level

Double

38

8

TRUE

Optional

ToGisOnly

SpecSymbology

Spec Symbology

String

50

TRUE

Optional

ToGisOnly

Voltage

Voltage

Double

38

8

TRUE

Optional

ToGisOnly


Relationships

RFCable / RFCable_D (RFCableData)

DHFC object name: RFCableData

GIS design table name: RFCable_D

GIS built table name: RFCable

GIS table type: FeatureClass

Geometry type: Path


Fields

Name

Alias

Type

Domain

Length

Precision

Nullable

Field Role

Data Transfer

CatalogId

CatalogId

Guid

FALSE

Required

BiDirectional

EsriId

OBJECTID

ObjectId

FALSE

Required

BiDirectional

FedFromComponentId

FedFromComponentId

Guid

FALSE

Required

BiDirectional

Geometry

SHAPE

Geometry

FALSE

Required

BiDirectional

IsInMdu

Is In Mdu

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

IsLocked

Is Locked

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

Length

Length

Double

38

8

FALSE

Required

BiDirectional

ModelNumber

Model Number

String

50

FALSE

Required

BiDirectional

NetworkId

NetworkId

Guid

FALSE

Required

BiDirectional

PoweringFedFromComponentId

PoweringFedFromComponentId

Guid

FALSE

Required

BiDirectional

Workflow_Status

Workflow Status

String

WorkflowState

FALSE

Required

BiDirectional

Active

Is Active

SmallInteger

EsriYesNoEnum

TRUE

Optional

ToGisOnly

CreationUser

Creation User

String

50

TRUE

Optional

BiDirectional

DateCreated

Date Created

Date

TRUE

Optional

BiDirectional

DateModified

Date Modified

Date

TRUE

Optional

BiDirectional

Diameter

Diameter

Double

38

8

TRUE

Optional

ToGisOnly

HubSite

HubSite

String

15

TRUE

Optional

ToGisOnly

InventoryNum

Inventory Number

String

50

TRUE

Optional

ToGisOnly

IsPowerOnly

Is Power Only

SmallInteger

EsriYesNoEnum

TRUE

Optional

ToGisOnly

LastUser

Last User

String

50

TRUE

Optional

BiDirectional

Manufacturer

Manufacturer

String

50

TRUE

Optional

ToGisOnly

Market

Market

String

255

TRUE

Optional

ToGisOnly

NodeName

Node Name

String

50

TRUE

Optional

ToGisOnly

SpecSymbology

Spec Symbology

String

50

TRUE

Optional

ToGisOnly


Relationships

RFCoupler / RFCoupler_D (RFCouplerData)

DHFC object name: RFCouplerData

GIS design table name: RFCoupler_D

GIS built table name: RFCoupler

GIS table type: FeatureClass

Geometry type: Point


Fields

Name

Alias

Type

Domain

Length

Precision

Nullable

Field Role

Data Transfer

AerialStructureId

AerialStructureId

Guid

FALSE

Required

BiDirectional

CatalogId

CatalogId

Guid

FALSE

Required

BiDirectional

CouplerType

Coupler Type

SmallInteger

CouplerType

FALSE

Required

BiDirectional

EsriId

OBJECTID

ObjectId

FALSE

Required

BiDirectional

FedFromComponentId

FedFromComponentId

Guid

FALSE

Required

BiDirectional

Flipped

Flipped

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

Geometry

SHAPE

Geometry

FALSE

Required

BiDirectional

HotDotPortNumber

Hot Dot Port Number

SmallInteger

FALSE

Required

BiDirectional

InternalPowerMapping

Internal Power Mapping

String

50

FALSE

Required

BiDirectional

IsInMdu

Is In Mdu

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

IsLocked

Is Locked

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

ModelNumber

Model Number

String

50

FALSE

Required

BiDirectional

NetworkId

NetworkId

Guid

FALSE

Required

BiDirectional

PoweringFedFromComponentId

PoweringFedFromComponentId

Guid

FALSE

Required

BiDirectional

SymbolRotation

Symbol Rotation

Double

38

8

FALSE

Required

BiDirectional

UGStructureId

UGStructureId

Guid

FALSE

Required

BiDirectional

Workflow_Status

Workflow Status

String

WorkflowState

FALSE

Required

BiDirectional

CreationUser

Creation User

String

50

TRUE

Optional

BiDirectional

DateCreated

Date Created

Date

TRUE

Optional

BiDirectional

DateModified

Date Modified

Date

TRUE

Optional

BiDirectional

DisplayValue

Display Value

String

50

TRUE

Optional

ToGisOnly

ForwardDownLossHigh

FWD Down Loss High

Double

38

8

TRUE

Optional

ToGisOnly

ForwardDownLossLow

FWD Loss Low

Double

38

8

TRUE

Optional

ToGisOnly

ForwardLossHigh

FWD Loss High

Double

38

8

TRUE

Optional

ToGisOnly

ForwardLossLow

FWD Loss Low

Double

38

8

TRUE

Optional

ToGisOnly

HubSite

HubSite

String

15

TRUE

Optional

ToGisOnly

InventoryNum

Inventory Number

String

50

TRUE

Optional

ToGisOnly

LastUser

Last User

String

50

TRUE

Optional

BiDirectional

Manufacturer

Manufacturer

String

50

TRUE

Optional

ToGisOnly

Market

Market

String

255

TRUE

Optional

ToGisOnly

NodeName

Node Name

String

50

TRUE

Optional

ToGisOnly

PortCount

Port Count

SmallInteger

TRUE

Optional

ToGisOnly

ReturnDownLossHigh

RET Down Loss High

Double

38

8

TRUE

Optional

ToGisOnly

ReturnDownLossLow

RET Down Loss Low

Double

38

8

TRUE

Optional

ToGisOnly

ReturnLossHigh

RET Loss High

Double

38

8

TRUE

Optional

ToGisOnly

ReturnLossLow

RET Loss Low

Double

38

8

TRUE

Optional

ToGisOnly

SpecSymbology

Spec Symbology

String

50

TRUE

Optional

ToGisOnly


Relationships

RFDoNotBuildBoundary / RFDoNotBuildBoundary_D (RFDoNotBuildBoundaryData)

DHFC object name: RFDoNotBuildBoundaryData

GIS design table name: RFDoNotBuildBoundary_D

GIS built table name: RFDoNotBuildBoundary

GIS table type: FeatureClass

Geometry type: Polygon


Fields

Name

Alias

Type

Domain

Length

Precision

Nullable

Field Role

Data Transfer

EsriId

OBJECTID

ObjectId

FALSE

Required

BiDirectional

Geometry

SHAPE

Geometry

FALSE

Required

BiDirectional

IsInMdu

Is In Mdu

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

Name

Name

String

50

FALSE

Required

BiDirectional

NetworkChangeNumber

Network Change Number

String

50

TRUE

Required

BiDirectional

NetworkId

NetworkId

Guid

FALSE

Required

BiDirectional

Workflow_Status

Workflow Status

String

WorkflowState

FALSE

Required

BiDirectional

CreationUser

Creation User

String

50

TRUE

Optional

BiDirectional

DateCreated

Date Created

Date

TRUE

Optional

BiDirectional

DateModified

Date Modified

Date

TRUE

Optional

BiDirectional

HubSite

HubSite

String

15

TRUE

Optional

ToGisOnly

LastUser

Last User

String

50

TRUE

Optional

BiDirectional

Market

Market

String

255

TRUE

Optional

ToGisOnly

NodeName

Node Name

String

50

TRUE

Optional

ToGisOnly

NodeNetworkID

NodeNetworkID

Guid

TRUE

Optional

ToGisOnly


Relationships

None.

RFHotDot / RFHotDot_D (RFHotDotData)

DHFC object name: RFHotDotData

GIS design table name: RFHotDot_D

GIS built table name: RFHotDot

GIS table type: FeatureClass

Geometry type: Point


Fields

Name

Alias

Type

Domain

Length

Precision

Nullable

Field Role

Data Transfer

ComponentId

Component Id

Guid

FALSE

Required

BiDirectional

EsriId

OBJECTID

ObjectId

FALSE

Required

BiDirectional

Geometry

SHAPE

Geometry

FALSE

Required

BiDirectional

IsInMdu

Is In Mdu

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

NetworkId

NetworkId

Guid

FALSE

Required

BiDirectional

SymbolRotation

Symbol Rotation

Double

38

8

FALSE

Required

BiDirectional

Workflow_Status

Workflow Status

String

WorkflowState

FALSE

Required

BiDirectional

CreationUser

Creation User

String

50

TRUE

Optional

BiDirectional

DateCreated

Date Created

Date

TRUE

Optional

BiDirectional

DateModified

Date Modified

Date

TRUE

Optional

BiDirectional

HubSite

HubSite

String

15

TRUE

Optional

ToGisOnly

LastUser

Last User

String

50

TRUE

Optional

BiDirectional

Market

Market

String

255

TRUE

Optional

ToGisOnly

NodeName

Node Name

String

50

TRUE

Optional

ToGisOnly

PortNumber

Port Number

SmallInteger

TRUE

Optional

ToGisOnly


Relationships

None.

RFHousingToHousing / RFHousingToHousing_D (RFHousingToHousingData)

DHFC object name: RFHousingToHousingData

GIS design table name: RFHousingToHousing_D

GIS built table name: RFHousingToHousing

GIS table type: FeatureClass

Geometry type: Line


Fields

Name

Alias

Type

Domain

Length

Precision

Nullable

Field Role

Data Transfer

AerialStructureId

AerialStructureId

Guid

FALSE

Required

BiDirectional

Angle

Angle

Double

38

8

FALSE

Required

BiDirectional

CatalogId

CatalogId

Guid

FALSE

Required

BiDirectional

EsriId

OBJECTID

ObjectId

FALSE

Required

BiDirectional

FedFromComponentId

FedFromComponentId

Guid

FALSE

Required

BiDirectional

Geometry

SHAPE

Geometry

FALSE

Required

BiDirectional

IsInMdu

Is In Mdu

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

LocationX

Center LocationX

Double

38

8

FALSE

Required

BiDirectional

LocationY

Center LocationY

Double

38

8

FALSE

Required

BiDirectional

ModelNumber

Model Number

String

50

FALSE

Required

BiDirectional

NetworkId

NetworkId

Guid

FALSE

Required

BiDirectional

PoweringFedFromComponentId

PoweringFedFromComponentId

Guid

FALSE

Required

BiDirectional

UGStructureId

UGStructureId

Guid

FALSE

Required

BiDirectional

Workflow_Status

Workflow Status

String

WorkflowState

FALSE

Required

BiDirectional

CreationUser

Creation User

String

50

TRUE

Optional

BiDirectional

DateCreated

Date Created

Date

TRUE

Optional

BiDirectional

DateModified

Date Modified

Date

TRUE

Optional

BiDirectional

InventoryNum

Inventory Number

String

50

TRUE

Optional

ToGisOnly

LastUser

Last User

String

50

TRUE

Optional

BiDirectional

Manufacturer

Manufacturer

String

50

TRUE

Optional

ToGisOnly

SpecSymbology

Spec Symbology

String

50

TRUE

Optional

ToGisOnly


Relationships

None.

RFInlineEq / RFInlineEq_D (RFInlineEqData)

DHFC object name: RFInlineEqData

GIS design table name: RFInlineEq_D

GIS built table name: RFInlineEq

GIS table type: FeatureClass

Geometry type: Point


Fields

Name

Alias

Type

Domain

Length

Precision

Nullable

Field Role

Data Transfer

AerialStructureId

AerialStructureId

Guid

FALSE

Required

BiDirectional

CatalogId

CatalogId

Guid

FALSE

Required

BiDirectional

ConditioningPluginCID

ConditioningPluginCID

Guid

TRUE

Required

BiDirectional

ConditioningPluginModelNumber

Conditioning Plugin Model Number

String

50

TRUE

Required

BiDirectional

EsriId

OBJECTID

ObjectId

FALSE

Required

BiDirectional

FedFromComponentId

FedFromComponentId

Guid

FALSE

Required

BiDirectional

Geometry

SHAPE

Geometry

FALSE

Required

BiDirectional

InternalPowerMapping

Internal Power Mapping

String

50

FALSE

Required

BiDirectional

IsInMdu

Is In Mdu

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

IsLocked

Is Locked

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

ModelNumber

Model Number

String

50

FALSE

Required

BiDirectional

NetworkId

NetworkId

Guid

FALSE

Required

BiDirectional

PoweringFedFromComponentId

PoweringFedFromComponentId

Guid

FALSE

Required

BiDirectional

SymbolRotation

Symbol Rotation

Double

38

8

FALSE

Required

BiDirectional

UGStructureId

UGStructureId

Guid

FALSE

Required

BiDirectional

Workflow_Status

Workflow Status

String

WorkflowState

FALSE

Required

BiDirectional

ConditioningPluginValue

Conditioning Plugin Value

Double

38

8

TRUE

Optional

ToGisOnly

CreationUser

Creation User

String

50

TRUE

Optional

BiDirectional

DateCreated

Date Created

Date

TRUE

Optional

BiDirectional

DateModified

Date Modified

Date

TRUE

Optional

BiDirectional

HubSite

HubSite

String

15

TRUE

Optional

ToGisOnly

InventoryNum

Inventory Number

String

50

TRUE

Optional

ToGisOnly

LastUser

Last User

String

50

TRUE

Optional

BiDirectional

Manufacturer

Manufacturer

String

50

TRUE

Optional

ToGisOnly

Market

Market

String

255

TRUE

Optional

ToGisOnly

NodeName

Node Name

String

50

TRUE

Optional

ToGisOnly

SpecSymbology

Spec Symbology

String

50

TRUE

Optional

ToGisOnly


Relationships

None.

RFNode / RFNode_D (RFNodeData)

DHFC object name: RFNodeData

GIS design table name: RFNode_D

GIS built table name: RFNode

GIS table type: FeatureClass

Geometry type: Point


Fields

Name

Alias

Type

Domain

Length

Precision

Nullable

Field Role

Data Transfer

AerialStructureId

AerialStructureId

Guid

FALSE

Required

BiDirectional

CatalogId

CatalogId

Guid

FALSE

Required

BiDirectional

EsriId

OBJECTID

ObjectId

FALSE

Required

BiDirectional

FedFromComponentId

FedFromComponentId

Guid

FALSE

Required

BiDirectional

Flipped

Flipped

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

Geometry

SHAPE

Geometry

FALSE

Required

BiDirectional

InternalPowerMapping

Internal Power Mapping

String

50

FALSE

Required

BiDirectional

IsInMdu

Is In Mdu

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

IsLocked

Is Locked

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

ModelNumber

Model Number

String

50

FALSE

Required

BiDirectional

Name

Name

String

50

FALSE

Required

BiDirectional

NetworkId

NetworkId

Guid

FALSE

Required

BiDirectional

PortConfiguration

Port Configuration

String

15

FALSE

Required

BiDirectional

PoweringFedFromComponentId

PoweringFedFromComponentId

Guid

FALSE

Required

BiDirectional

ProjectFileCatalogId

Project File Catalog Id

Guid

FALSE

Required

BiDirectional

ProjectFileName

Project File Name

String

50

FALSE

Required

BiDirectional

SegmentationConfiguration

Segmentation Configuration

String

70

TRUE

Required

BiDirectional

SegmentationMode

Segmentation Mode

SmallInteger

NodeSegmentation

TRUE

Required

BiDirectional

SymbolRotation

Symbol Rotation

Double

38

8

FALSE

Required

BiDirectional

UGStructureId

UGStructureId

Guid

FALSE

Required

BiDirectional

Workflow_Status

Workflow Status

String

WorkflowState

FALSE

Required

BiDirectional

Amperage

Amperage

Double

38

8

TRUE

Optional

ToGisOnly

CoaxPortCount

Coax Port Count

SmallInteger

TRUE

Optional

ToGisOnly

CreationUser

Creation User

String

50

TRUE

Optional

BiDirectional

DateCreated

Date Created

Date

TRUE

Optional

BiDirectional

DateModified

Date Modified

Date

TRUE

Optional

BiDirectional

DesignFrequency

RF Design FWD Frequency High

Double

38

8

TRUE

Optional

ToGisOnly

FiberPortCount

Fiber Port Count

SmallInteger

TRUE

Optional

ToGisOnly

ForwardOutputHighSignalLevel

ForwardOutputHighSignalLevel

Double

38

8

TRUE

Optional

ToGisOnly

ForwardOutputLowSignalLevel

ForwardOutputLowSignalLevel

Double

38

8

TRUE

Optional

ToGisOnly

HubSite

HubSite

String

15

TRUE

Optional

BiDirectional

InventoryNum

Inventory Number

String

50

TRUE

Optional

ToGisOnly

LastUser

Last User

String

50

TRUE

Optional

BiDirectional

Manufacturer

Manufacturer

String

50

TRUE

Optional

ToGisOnly

Market

Market

String

255

TRUE

Optional

BiDirectional

PowerSupplyId

Power Supply Id

Guid

TRUE

Optional

ToGisOnly

ReturnInputHighSignalLevel

ReturnInputHighSignalLevel

Double

38

8

TRUE

Optional

ToGisOnly

ReturnInputLowSignalLevel

ReturnInputLowSignalLevel

Double

38

8

TRUE

Optional

ToGisOnly

SpecSymbology

Spec Symbology

String

50

TRUE

Optional

ToGisOnly

TotalHomesPassed

TotalHomesPassed

SmallInteger

TRUE

Optional

ToGisOnly

TotalHomesPassedLegA

TotalHomesPassedLegA

Integer

TRUE

Optional

ToGisOnly

TotalHomesPassedLegB

TotalHomesPassedLegB

Integer

TRUE

Optional

ToGisOnly

TotalHomesPassedLegC

TotalHomesPassedLegC

Integer

TRUE

Optional

ToGisOnly

TotalHomesPassedLegD

TotalHomesPassedLegD

Integer

TRUE

Optional

ToGisOnly

Voltage

Voltage

Double

38

8

TRUE

Optional

ToGisOnly


Relationships

None.

RFNodeBoundary / RFNodeBoundary_D (RFNodeBoundaryData)

DHFC object name: RFNodeBoundaryData

GIS design table name: RFNodeBoundary_D

GIS built table name: RFNodeBoundary

GIS table type: FeatureClass

Geometry type: Polygon


Fields

Name

Alias

Type

Domain

Length

Precision

Nullable

Field Role

Data Transfer

EsriId

OBJECTID

ObjectId

FALSE

Required

BiDirectional

Geometry

SHAPE

Geometry

FALSE

Required

BiDirectional

Name

Name

String

50

TRUE

Required

BiDirectional

NetworkId

NetworkId

Guid

FALSE

Required

BiDirectional

NodeNetworkId

NodeNetworkId

Guid

FALSE

Required

BiDirectional

Workflow_Status

Workflow Status

String

WorkflowState

FALSE

Required

BiDirectional

CreationUser

Creation User

String

50

TRUE

Optional

BiDirectional

DateCreated

Date Created

Date

TRUE

Optional

BiDirectional

DateModified

Date Modified

Date

TRUE

Optional

BiDirectional

HubSite

HubSite

String

15

TRUE

Optional

ToGisOnly

LastUser

Last User

String

50

TRUE

Optional

BiDirectional

Market

Market

String

255

TRUE

Optional

ToGisOnly


Relationships

None.

RFPowerBlock / RFPowerBlock_D (RFPowerBlockData)

DHFC object name: RFPowerBlockData

GIS design table name: RFPowerBlock_D

GIS built table name: RFPowerBlock

GIS table type: FeatureClass

Geometry type: Point


Fields

Name

Alias

Type

Domain

Length

Precision

Nullable

Field Role

Data Transfer

EsriId

OBJECTID

ObjectId

FALSE

Required

BiDirectional

Geometry

SHAPE

Geometry

FALSE

Required

BiDirectional

IsInMdu

Is In Mdu

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

NetworkId

NetworkId

Guid

FALSE

Required

BiDirectional

SymbolRotation

Symbol Rotation

Double

38

8

FALSE

Required

BiDirectional

Workflow_Status

Workflow Status

String

WorkflowState

FALSE

Required

BiDirectional

CreationUser

Creation User

String

50

TRUE

Optional

BiDirectional

DateCreated

Date Created

Date

TRUE

Optional

BiDirectional

DateModified

Date Modified

Date

TRUE

Optional

BiDirectional

HubSite

HubSite

String

15

TRUE

Optional

ToGisOnly

LastUser

Last User

String

50

TRUE

Optional

BiDirectional

Market

Market

String

255

TRUE

Optional

ToGisOnly

NodeName

Node Name

String

50

TRUE

Optional

ToGisOnly

PortNumber

Port Number

SmallInteger

TRUE

Optional

ToGisOnly


Relationships

None.

RFPowerInserter / RFPowerInserter_D (RFPowerInserterData)

DHFC object name: RFPowerInserterData

GIS design table name: RFPowerInserter_D

GIS built table name: RFPowerInserter

GIS table type: FeatureClass

Geometry type: Point


Fields

Name

Alias

Type

Domain

Length

Precision

Nullable

Field Role

Data Transfer

AerialStructureId

AerialStructureId

Guid

FALSE

Required

BiDirectional

CatalogId

CatalogId

Guid

FALSE

Required

BiDirectional

EsriId

OBJECTID

ObjectId

FALSE

Required

BiDirectional

FedFromComponentId

FedFromComponentId

Guid

FALSE

Required

BiDirectional

Flipped

Flipped

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

Geometry

SHAPE

Geometry

FALSE

Required

BiDirectional

InternalPowerMapping

Internal Power Mapping

String

50

FALSE

Required

BiDirectional

IsInMdu

Is In Mdu

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

IsLocked

Is Locked

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

ModelNumber

Model Number

String

50

FALSE

Required

BiDirectional

NetworkId

NetworkId

Guid

FALSE

Required

BiDirectional

PoweringFedFromComponentId

PoweringFedFromComponentId

Guid

FALSE

Required

BiDirectional

SymbolRotation

Symbol Rotation

Double

38

8

FALSE

Required

BiDirectional

UGStructureId

UGStructureId

Guid

FALSE

Required

BiDirectional

Workflow_Status

Workflow Status

String

WorkflowState

FALSE

Required

BiDirectional

CreationUser

Creation User

String

50

TRUE

Optional

BiDirectional

CurrentLeft

Current Usage Upstream

Double

38

8

TRUE

Optional

ToGisOnly

CurrentRight

Current Usage Downstream

Double

38

8

TRUE

Optional

ToGisOnly

DateCreated

Date Created

Date

TRUE

Optional

BiDirectional

DateModified

Date Modified

Date

TRUE

Optional

BiDirectional

HubSite

HubSite

String

15

TRUE

Optional

ToGisOnly

InventoryNum

Inventory Number

String

50

TRUE

Optional

ToGisOnly

LastUser

Last User

String

50

TRUE

Optional

BiDirectional

Manufacturer

Manufacturer

String

50

TRUE

Optional

ToGisOnly

Market

Market

String

255

TRUE

Optional

ToGisOnly

NodeName

Node Name

String

50

TRUE

Optional

ToGisOnly


Relationships

RFPowerSupply / RFPowerSupply_D (RFPowerSupplyData)

DHFC object name: RFPowerSupplyData

GIS design table name: RFPowerSupply_D

GIS built table name: RFPowerSupply

GIS table type: FeatureClass

Geometry type: Point


Fields

Name

Alias

Type

Domain

Length

Precision

Nullable

Field Role

Data Transfer

EsriId

OBJECTID

ObjectId

FALSE

Required

BiDirectional

Geometry

SHAPE

Geometry

FALSE

Required

BiDirectional

Name

Name

String

50

FALSE

Required

BiDirectional

NetworkId

NetworkId

Guid

FALSE

Required

BiDirectional

PowerSupplyId

PowerSupplyId

Guid

FALSE

Required

BiDirectional

Workflow_Status

Workflow Status

String

WorkflowState

FALSE

Required

BiDirectional

CreationUser

Creation User

String

50

TRUE

Optional

BiDirectional

DateCreated

Date Created

Date

TRUE

Optional

BiDirectional

DateModified

Date Modified

Date

TRUE

Optional

BiDirectional

LastUser

Last User

String

50

TRUE

Optional

BiDirectional


Relationships

RFPowerSupplyBoundary / RFPowerSupplyBoundary_D (RFPowerSupplyBoundaryData)

DHFC object name: RFPowerSupplyBoundaryData

GIS design table name: RFPowerSupplyBoundary_D

GIS built table name: RFPowerSupplyBoundary

GIS table type: FeatureClass

Geometry type: Polygon


Fields

Name

Alias

Type

Domain

Length

Precision

Nullable

Field Role

Data Transfer

EsriId

OBJECTID

ObjectId

FALSE

Required

BiDirectional

Geometry

SHAPE

Geometry

FALSE

Required

BiDirectional

Name

Name

String

50

FALSE

Required

BiDirectional

NetworkId

NetworkId

Guid

FALSE

Required

BiDirectional

PowerSupplyId

PowerSupplyId

Guid

FALSE

Required

BiDirectional

Workflow_Status

Workflow Status

String

WorkflowState

FALSE

Required

BiDirectional

CreationUser

Creation User

String

50

TRUE

Optional

BiDirectional

DateCreated

Date Created

Date

TRUE

Optional

BiDirectional

DateModified

Date Modified

Date

TRUE

Optional

BiDirectional

LastUser

Last User

String

50

TRUE

Optional

BiDirectional


Relationships

None.

RFSegmentableNodeBoundary / RFSegmentableNodeBoundary_D (RFSegmentableNodeBoundaryData)

DHFC object name: RFSegmentableNodeBoundaryData

GIS design table name: RFSegmentableNodeBoundary_D

GIS built table name: RFSegmentableNodeBoundary

GIS table type: FeatureClass

Geometry type: Polygon


Fields

Name

Alias

Type

Domain

Length

Precision

Nullable

Field Role

Data Transfer

EsriId

OBJECTID

ObjectId

FALSE

Required

BiDirectional

Geometry

SHAPE

Geometry

FALSE

Required

BiDirectional

LegsServed

Legs Served

String

15

FALSE

Required

BiDirectional

LegsServedLabels

Legs Served Labels

String

15

FALSE

Required

BiDirectional

Name

Name

String

50

FALSE

Required

BiDirectional

NetworkId

NetworkId

Guid

FALSE

Required

BiDirectional

NodeNetworkId

NodeNetworkId

Guid

FALSE

Required

BiDirectional

Workflow_Status

Workflow Status

String

WorkflowState

FALSE

Required

BiDirectional

CreationUser

Creation User

String

50

TRUE

Optional

BiDirectional

DateCreated

Date Created

Date

TRUE

Optional

BiDirectional

DateModified

Date Modified

Date

TRUE

Optional

BiDirectional

HubSite

HubSite

String

15

TRUE

Optional

ToGisOnly

LastUser

Last User

String

50

TRUE

Optional

BiDirectional

Market

Market

String

255

TRUE

Optional

ToGisOnly


Relationships

None.

RFSplice / RFSplice_D (RFSpliceData)

DHFC object name: RFSpliceData

GIS design table name: RFSplice_D

GIS built table name: RFSplice

GIS table type: FeatureClass

Geometry type: Point


Fields

Name

Alias

Type

Domain

Length

Precision

Nullable

Field Role

Data Transfer

AerialStructureId

AerialStructureId

Guid

FALSE

Required

BiDirectional

CatalogId

CatalogId

Guid

FALSE

Required

BiDirectional

EsriId

OBJECTID

ObjectId

FALSE

Required

BiDirectional

FedFromComponentId

FedFromComponentId

Guid

FALSE

Required

BiDirectional

FeedsComponentId

FeedsComponentId

Guid

FALSE

Required

BiDirectional

Geometry

SHAPE

Geometry

FALSE

Required

BiDirectional

IsInMdu

Is In Mdu

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

IsLocked

Is Locked

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

ModelNumber

Model Number

String

50

FALSE

Required

BiDirectional

NetworkId

NetworkId

Guid

FALSE

Required

BiDirectional

PoweringFedFromComponentId

PoweringFedFromComponentId

Guid

FALSE

Required

BiDirectional

SymbolRotation

Symbol Rotation

Double

38

8

FALSE

Required

BiDirectional

UGStructureId

UGStructureId

Guid

FALSE

Required

BiDirectional

Workflow_Status

Workflow Status

String

WorkflowState

FALSE

Required

BiDirectional

CreationUser

Creation User

String

50

TRUE

Optional

BiDirectional

DateCreated

Date Created

Date

TRUE

Optional

BiDirectional

DateModified

Date Modified

Date

TRUE

Optional

BiDirectional

Diameter

Diameter

Double

38

8

TRUE

Optional

ToGisOnly

HubSite

HubSite

String

15

TRUE

Optional

ToGisOnly

InventoryNum

Inventory Number

String

50

TRUE

Optional

ToGisOnly

LastUser

Last User

String

50

TRUE

Optional

BiDirectional

Manufacturer

Manufacturer

String

50

TRUE

Optional

ToGisOnly

Market

Market

String

255

TRUE

Optional

ToGisOnly

NodeName

Node Name

String

50

TRUE

Optional

ToGisOnly

SpecSymbology

Spec Symbology

String

50

TRUE

Optional

ToGisOnly

Type

Splice Type

SmallInteger

SpliceType

TRUE

Optional

ToGisOnly


Relationships

None.

RFTap / RFTap_D (RFTapData)

DHFC object name: RFTapData

GIS design table name: RFTap_D

GIS built table name: RFTap

GIS table type: FeatureClass

Geometry type: Point


Fields

Name

Alias

Type

Domain

Length

Precision

Nullable

Field Role

Data Transfer

AerialStructureId

AerialStructureId

Guid

FALSE

Required

BiDirectional

CatalogId

CatalogId

Guid

FALSE

Required

BiDirectional

ConditioningPluginCID

Conditioning Plugin CID

Guid

FALSE

Required

BiDirectional

ConditioningPluginModelNumber

Conditioning Plugin Model Number

String

50

TRUE

Required

BiDirectional

ConditioningPluginType

Conditioning Plugin Type

SmallInteger

RFConditioningPluginTypes

TRUE

Required

BiDirectional

EsriId

OBJECTID

ObjectId

FALSE

Required

BiDirectional

FedFromComponentId

FedFromComponentId

Guid

FALSE

Required

BiDirectional

Geometry

SHAPE

Geometry

FALSE

Required

BiDirectional

IsInMdu

Is In Mdu

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

IsLocked

Is Locked

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

ModelNumber

Model Number

String

50

FALSE

Required

BiDirectional

Name

Name

String

50

TRUE

Required

BiDirectional

NetworkId

NetworkId

Guid

FALSE

Required

BiDirectional

PoweringFedFromComponentId

PoweringFedFromComponentId

Guid

FALSE

Required

BiDirectional

SymbolRotation

Symbol Rotation

Double

38

8

FALSE

Required

BiDirectional

UGStructureId

UGStructureId

Guid

FALSE

Required

BiDirectional

Workflow_Status

Workflow Status

String

WorkflowState

FALSE

Required

BiDirectional

ConditioningPluginValue

Conditioning Plugin Value

Double

38

8

TRUE

Optional

ToGisOnly

CreationUser

Creation User

String

50

TRUE

Optional

BiDirectional

DateCreated

Date Created

Date

TRUE

Optional

BiDirectional

DateModified

Date Modified

Date

TRUE

Optional

BiDirectional

DistanceToLastActive

Distance To Last Active

Double

38

8

TRUE

Optional

ToGisOnly

ForwardDropSignalHigh

FWD Drop High

Double

38

8

TRUE

Optional

ToGisOnly

ForwardDropSignalLow

FWD Drop Low

Double

38

8

TRUE

Optional

ToGisOnly

ForwardOutputHighLevel

FWD Output High

Double

38

8

TRUE

Optional

ToGisOnly

ForwardOutputLowLevel

FWD Output Low

Double

38

8

TRUE

Optional

ToGisOnly

FrequencyRange

Frequency Range

String

50

TRUE

Optional

ToGisOnly

HubSite

HubSite

String

15

TRUE

Optional

ToGisOnly

InventoryNum

Inventory Number

String

50

TRUE

Optional

ToGisOnly

IsEndOfLine

Is End Of Line

SmallInteger

EsriYesNoEnum

TRUE

Optional

ToGisOnly

IsPTap

Is PTap

SmallInteger

EsriYesNoEnum

TRUE

Optional

ToGisOnly

IsSelfTerminating

Is Self Terminating

SmallInteger

EsriYesNoEnum

TRUE

Optional

ToGisOnly

LastUser

Last User

String

50

TRUE

Optional

BiDirectional

Manufacturer

Manufacturer

String

50

TRUE

Optional

ToGisOnly

Market

Market

String

255

TRUE

Optional

ToGisOnly

NodeName

Node Name

String

50

TRUE

Optional

ToGisOnly

PortCount

Port Count

SmallInteger

TRUE

Optional

ToGisOnly

ReturnSignalHighFrequency

RTN Signal High Frequency

Double

38

8

TRUE

Optional

ToGisOnly

ReturnSignalHighLevel

RTN Signal High Level

Double

38

8

TRUE

Optional

ToGisOnly

ReturnSignalLowFrequency

RTN Signal Low Frequency

Double

38

8

TRUE

Optional

ToGisOnly

ReturnSignalLowLevel

RTN Signal High Level

Double

38

8

TRUE

Optional

ToGisOnly

SpecSymbology

Spec Symbology

String

50

TRUE

Optional

ToGisOnly

TapValue

Tap Value

Double

38

8

TRUE

Optional

ToGisOnly


Relationships

RFTerminator / RFTerminator_D (RFTerminatorData)

DHFC object name: RFTerminatorData

GIS design table name: RFTerminator_D

GIS built table name: RFTerminator

GIS table type: FeatureClass

Geometry type: Point


Fields

Name

Alias

Type

Domain

Length

Precision

Nullable

Field Role

Data Transfer

AerialStructureId

AerialStructureId

Guid

FALSE

Required

BiDirectional

CatalogId

CatalogId

Guid

FALSE

Required

BiDirectional

EsriId

OBJECTID

ObjectId

FALSE

Required

BiDirectional

FedFromComponentId

FedFromComponentId

Guid

FALSE

Required

BiDirectional

Geometry

SHAPE

Geometry

FALSE

Required

BiDirectional

IsInMdu

Is In Mdu

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

IsInputTerminator

Is Input Terminator

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

IsLocked

Is Locked

SmallInteger

EsriYesNoEnum

FALSE

Required

BiDirectional

ModelNumber

Model Number

String

50

FALSE

Required

BiDirectional

NetworkId

NetworkId

Guid

FALSE

Required

BiDirectional

PoweringFedFromComponentId

PoweringFedFromComponentId

Guid

FALSE

Required

BiDirectional

SymbolRotation

Symbol Rotation

Double

38

8

FALSE

Required

BiDirectional

UGStructureId

UGStructureId

Guid

FALSE

Required

BiDirectional

Workflow_Status

Workflow Status

String

WorkflowState

FALSE

Required

BiDirectional

CreationUser

Creation User

String

50

TRUE

Optional

BiDirectional

DateCreated

Date Created

Date

TRUE

Optional

BiDirectional

DateModified

Date Modified

Date

TRUE

Optional

BiDirectional

DistanceToLastActive

Distance To Last Active

Double

38

8

TRUE

Optional

ToGisOnly

ForwardOutputHighLevel

FWD Output High Level

Double

38

8

TRUE

Optional

ToGisOnly

ForwardOutputLowLevel

FWD Output Low Level

Double

38

8

TRUE

Optional

ToGisOnly

HubSite

HubSite

String

15

TRUE

Optional

ToGisOnly

InventoryNum

Inventory Number

String

50

TRUE

Optional

ToGisOnly

IsCamera

Is Camera

SmallInteger

EsriYesNoEnum

TRUE

Optional

ToGisOnly

LastUser

Last User

String

50

TRUE

Optional

BiDirectional

Manufacturer

Manufacturer

String

50

TRUE

Optional

ToGisOnly

Market

Market

String

255

TRUE

Optional

ToGisOnly

NodeName

Node Name

String

50

TRUE

Optional

ToGisOnly

SpecSymbology

Spec Symbology

String

50

TRUE

Optional

ToGisOnly


Relationships

None.

QR Code is a registered trademark of DENSO WAVE INCORPORATED in Japan and other countries.