Backup Power Solutions, Single Phase
Class 1130 / Refer to Catalog 1100CT0501
Backup Power Solutions
1Ø3W—120/240 Vac Backup Power—UL Listed
Backup Power Solutions
Mains Rating (A) |
Spaces |
Max. Single Pole Circuits [1] |
Max. |
Load Center Box, Interior and Cover |
Equipment Grounding Bar Kit (Order Separately) |
Main Wire Size AWG/kcmil |
Bus Rating |
Box No. [2] |
||
---|---|---|---|---|---|---|---|---|---|---|
Al |
Cu |
|||||||||
I |
Generator Panels—Manual Transfer for Sub-Feed Applications NEMA 1 (Indoor) |
|||||||||
Factory-Installed Main Circuit Breakers with Mechanical Interlock—10 kA Short Circuit Current Rating |
||||||||||
30 |
4 |
8 |
4 |
14–8 |
14–8 |
30 |
4 |
|||
60 |
4 |
8 |
4 |
8–2 |
8–2 |
60 |
4 |
|||
Split Bus Plug-on Neutral Load Centers—Manual Transfer for use with Temporary Backup Power Source Applications NEMA 1 (Indoor) |
||||||||||
200 |
48 |
48 |
0 |
QO122X26M200PC OBS |
4–250 |
4–250 |
— |
12 |
||
36 |
69 |
34 |
4–250 |
4–250 |
— |
12 |
||||
R |
Generator Panels—Manual Transfer with Generator Power Inlet Plug for Sub-Feed Applications NEMA 3R (Outdoor) |
|||||||||
Factory-Installed Main Circuit Breakers with Mechanical Interlock—10 kA Short Circuit Current Rating |
||||||||||
100 |
4 |
8 |
4 |
QO1DM10020TRBR OBS |
Factory-Installed |
— |
8–2 |
100 |
17R |
|
4 |
8 |
4 |
— |
100 |
17R |
|||||
4 |
8 |
4 |
— |
100 |
17R |
|||||
Split Bus Plug-on Neutral Load Centers—Manual Transfer for use with Temporary Backup Power Source Applications NEMA 1 (Indoor) |
||||||||||
200 |
48 |
48 |
0 |
QO122X26M200PC OBS |
— |
4–250 |
— |
12 |
||
OBS This product is obsolete. |
Manual Power Transfer Accessories
Description |
Cat. No. |
Schedule |
|
---|---|---|---|
Manual Transfer Equipment Kit |
For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-by-side so that only one circuit breaker can be “ON’’ at a time. |
DE2E |
|
QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual power supply applications. Can be used with (2) 2P or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers. |
DE2E |
||
Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back-up power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. |
DE3A |
||
Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back-up power supply applications. For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02. |
DE3A |
||
Secures two 2P circuit breakers to left side of interior when used as back-fed mains, a QO2DTI Kit included for back-up power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. |
DE3A |
||
Generator Circuit Breaker Interlock Kit |
For use on “G” and “S” Series NEMA 1 and “G”, “S1” and “S2” Series NEMA 3R load centers. Interlocks a QOM1 2P main circuit breaker of a load center (100–125 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. |
DE3A |
|
For use on “G” and “S” Series NEMA 1 and “G” and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. |
DE3A |
||
For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. |
DE3A |