Rainproof, Meter Mains and All-In-Ones, 300–400 A
Class 4119, 4120 / Refer to Catalog / Refer to Catalog 4120CT2201
PoN Meter Mains and All-in-Ones (300–400 A Devices)
|
PoN Meter Mains and All-in-Ones
|
|
Meter Mains: Meets Federal Specification W-P-115c as Type 1, Class 2, UL Listed, suitable only for use as service equipment, 120/240 Vac, 1Ø3W, NEMA 3R Enclosure
Meter Mains
|
Ampere Rating |
Bypass Type |
Service |
Short Circuit |
Cat. No. |
Service Disconnect(s) [1] |
Load Center and
Branch |
Hub Type |
Line |
Bus Rating |
Service |
Weight |
||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Max. Quantity |
Ampere |
||||||||||||||||
|
Spaces |
1P |
||||||||||||||||
|
Circuits |
Tandems |
||||||||||||||||
|
UL |
UL and |
2P |
Type |
Ampere Rating |
|||||||||||||
|
Ring Type, QO |
|||||||||||||||||
|
Surface and Semiflush Mount [1] |
|||||||||||||||||
|
400 A |
None |
UG |
UG |
25 kA |
1 |
QDL22200 [7] |
200 A |
8 |
16 |
8 |
200 A |
A–L |
(2) Studs |
225 |
4–250 |
108, 4 |
|
|
400 A |
Class 320 Manual Bypass |
UG |
— |
25 kA |
QDL, QGL, QJL [10] |
A–L |
(2) Studs |
225 |
4–250 |
108, 4 |
|||||||
|
400 A |
Class 320 Manual Bypass |
UG |
— |
65 kA [1] |
1 |
400 A |
— |
2 [11] |
— |
200 A |
A–L |
(2) Studs |
— |
4–250 |
115, 4 |
||
|
Ringless Type, QO |
|||||||||||||||||
|
400 A |
Class |
OH/UG |
— |
25 kA |
1 |
QDL, QGL, QJL [10] |
200 A |
— |
— |
— |
— |
A–L |
4–600 |
— |
12–2/0 |
75, 4 |
|
|
1 |
QDL, QGL, QJL [10] |
200 A |
— |
— |
— |
— |
|||||||||||
|
Surface Mount Only, Supplied with Feed-Thru Lugs and Provisions for Branch Circuit Breakers |
|||||||||||||||||
|
400 A |
UG |
— |
25 kA |
1 |
QDL22200 [7] QDL, QGL, QJL [10] |
200 A |
8 |
16 |
8 |
200 A |
A–L |
(2) Studs |
225 |
4–250 |
108, 4 |
||
|
400 A |
Class |
OH/UG |
— |
25 kA |
1 |
QDL22200 [7] |
200 A |
8 |
16 |
8 |
200 A |
A–L |
4–600 |
225 |
12–2/0 |
77, 4 |
|
|
1 |
QDL, QGL, QJL [10] |
200 A |
|||||||||||||||
|
Surface and Semiflush Mount [1] |
|||||||||||||||||
|
400 A |
Class 320 Lever |
UG |
— |
25 kA |
1 |
QDL22200 [7] |
200 A |
8 |
16 |
8 |
200 A |
A–L |
(2) Studs |
225 |
4–250 |
108, 4 |
|
|
400 A |
Class 320 Lever |
UG |
— |
65 kA [1] |
1 |
400 A |
— |
2 [11] |
— |
200 A |
A–L |
(2) Studs |
— |
4–250 |
120, 4 |
||
|
Ringless Type, Homeline |
|||||||||||||||||
|
Surface Mount Only, Supplied with Feed-Thru Lugs and Provisions for Branch Circuit Breakers |
|||||||||||||||||
|
400 A |
Class |
OH/UG |
— |
25 kA |
1 |
QDL22200 [7] |
200 A |
8 |
16 |
8 |
200 A |
A–L |
4–600 |
225 |
12–2/0 |
77, 4 |
|
|
1 |
QDL, QGL, QJL [10] |
||||||||||||||||
All-in-One Combination Service Entrance Devices
| Surface and Semiflush Mount[1] | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Ring Type, Homeline |
|||||||||||||||||
| 300 A | Class 320 Manual | UG | — | 25 kA | 1 | QDL22200 [7] QDL, QGL, QJL [10] |
200 A 100 A |
20 | 40 | 20 | 200 A | A–L | (2) Studs | 225 | 4–250 | 106, 4 | |
|
|
1 | ||||||||||||||||
| 400 A | None | UG | UG | 25 kA | 1 | QDL22200 [7] QDL, QGL, QJL [10] |
200
A 200 A |
20 | 40 | 20 | 200 A | A–L | (2) Studs | 225 | 4–250 | 106, 4 | |
| 1 | 225 | ||||||||||||||||
| 400 A | Class 320 Manual | UG | — | 25 kA |
|
1 | QDL22200 [7] | 200 A | 20 | 40 | 20 | 200 A | A–L | (2) Studs | 225 | 4–250 | 106, 4 |
| 1 | QDL, QGL, QJL [10] | 200 A | 225 | ||||||||||||||
|
Ringless, Homeline |
|||||||||||||||||
| 400 A | Class 320 Lever | UG | — | 25 kA |
|
1 | QDL22200 [9] | 200 A | 20 | 40 | 20 | 200 A | A–L | (2) Studs | 225 | 4–250 | 109, 4 |