Homeline Load Centers, Indoor, Single Phase
Class 1170 / Refer to Catalog 1100CT0501
HOM Standard Load Center Main Lugs, Fixed Mains
1Ø3W—120/240 Vac Indoor—UL Listed
Fixed Main Lugs Load Centers (Accepts Only HOM Plug-on Circuit Breakers - Not compatible with HOM Plug-on Neutral Circuit Breakers)
|
Mains Rating |
Spaces |
Max. Single Pole Circuits [1] |
Max. Tandem Circuit Breakers |
Load Center Box, Interior and Cover [2] |
Main Wire Size AWG/kcmil |
Bus Rating |
Equipment Ground Bar Kit (Order Separately) |
Box No. [3] |
||
|---|---|---|---|---|---|---|---|---|---|---|
|
Al |
Cu |
|||||||||
|
I N D O O R |
Main Lugs—10 kA Short Circuit Current Rating Order HOM Circuit Breakers (See Homeline™ Circuit Breakers) Factory-installed Fixed Main Lugs |
|||||||||
|
70 A |
2 |
4 |
2 |
12–3 |
14–4 |
70 |
2 |
|||
|
100 A |
6 |
12 |
6 |
8–1 |
100 |
4 |
||||
|
125 A |
4 |
8 |
4 |
12–2/0 |
14–2/0 |
125 |
PK7GTA Included |
21 |
||
HOM Plug-on Neutral Load Center Main Lugs, Convertible Mains
1Ø3W—120/240 Vac Indoor—UL Listed
Convertible Main Lugs Plug-on Neutral Load Centers (Compatible with HOM Plug-on Circuit Breakers and HOM Plug-on Neutral Circuit Breakers)
|
Mains Rating |
Spaces |
Max. Single Pole Circuits [1] |
Max. Tandem Circuit Breakers |
Load Center Box, Interior and Cover [2] |
Main Wire Size AWG/kcmil |
Bus Rating |
Equipment Ground Bar Kit (Order Separately) |
Box No. [3] |
||
|---|---|---|---|---|---|---|---|---|---|---|
|
Al |
Cu |
|||||||||
|
I N D O O R |
Convertible
Mains—Factory-installed Main Lugs |
|||||||||
|
125 A |
8 |
16 |
8 |
6–2/0 |
6–1 |
125 |
6 |
|||
|
12 |
24 |
12 |
6–1 |
125 |
6 |
|||||
|
16 |
32 |
16 |
6–1/0 |
125 |
8 |
|||||
|
20 |
40 |
20 |
6–1/0 |
125 |
8 |
|||||
|
30 |
60 |
30 |
6–2/0 |
125 |
10 |
|||||
|
Convertible
Mains—Factory-installed Main Lugs |
||||||||||
|
225 A |
30 |
60 |
30 |
4–300 |
4–250 |
225 |
10 |
|||
|
40 |
80 |
40 |
225 |
12 |
||||||
|
42 |
84 |
42 |
225 |
12 |
||||||
|
60 |
120 |
60 |
225 |
25 |
||||||
|
Convertible Mains—Factory-installed
Main Lugs—Ground Bar Included |
||||||||||
|
125 A |
8 |
16 |
8 |
6–2/0 |
6–1 |
125 |
6 |
|||
|
12 |
24 |
12 |
6–1 |
125 |
6 |
|||||
|
20 |
40 |
20 |
6–1/0 |
125 |
8 |
|||||
|
24 |
48 |
24 |
6–1/0 |
125 |
8 |
|||||
|
Convertible Mains—Factory-installed
Main Lugs—Ground Bar Included |
||||||||||
|
225 A |
30 |
60 |
30 |
4–300 |
4–250 |
225 |
10 |
|||
|
16 |
32 |
16 |
225 |
9 |
||||||
|
20 |
40 |
20 |
225 |
9 |
||||||
|
40 |
80 |
40 |
225 |
12 |
||||||
|
42 |
84 |
42 |
225 |
12 |
||||||
| Above listings
through 200 A mains rating meet Federal Specification W-P-115c as
Type 1, Class 2. OBS This product is obsolete. |
||||||||||
Field-Installed Main Circuit Breaker Kits, 1Ø
These tables define application and selection criteria for field‑installed QOM main circuit breaker kits used in convertible main load centers for single‑phase (Ø) systems. They cover QOM1 frame sizes rated 50–125 A and QOM2 frame sizes rated 100–225 A, aligned with permitted load center mains ratings and 22 kA AIR short‑circuit capability. Listed data includes approved breaker catalog numbers, conductor lug wire size ranges, UL usage conditions, maximum load ratings, and optional shunt‑trip configuration requirements to support code‑compliant electrical installations.
note
QOM1 Frame Size
|
Main Circuit Breaker Rating [7] |
Convertible Load Center Mains Rating |
22 k AIR [8] |
Lug Wire Size [9] AWG/kcmil |
|---|---|---|---|
|
Main Circuit Breaker |
|||
|
50 A |
100–125 |
12–2/0 Al or Cu |
|
|
60 A |
100–125 |
||
|
70 A |
100–125 |
||
|
80 A |
100–125 |
||
|
90 A |
100–125 |
||
|
100 A |
100–125 |
||
|
110 A |
125 |
||
|
125 A |
125 |
HOM Plug-on Neutral Load Center Main Breaker, Convertible Mains
1Ø3W—120/240 Vac Indoor—UL Listed
Convertible Main Breaker Plug-on Neutral Load Centers (Compatible with HOM Plug-on Circuit Breakers and HOM Plug-on Neutral Circuit Breakers)
|
Mains Rating |
Spaces |
Max. Single Pole Circuits [1] |
Max. Tandem Circuit Breakers |
Load Center Box, Interior and Cover [2] |
Main Wire Size AWG/kcmil |
Bus Rating |
Equipment Ground Bar Kit (Order Separately) |
Box No. [3] |
||
|---|---|---|---|---|---|---|---|---|---|---|
|
Al |
Cu |
|||||||||
|
I N D O O R |
Main Circuit Breaker—22 kA Short Circuit Current Rating |
|||||||||
|
100 A |
8 |
16 |
8 |
6–1 |
125 |
5 |
||||
|
12 |
24 |
12 |
6–2/0 |
125 |
6 |
|||||
|
20 |
40 |
20 |
6–1 |
125 |
7 |
|||||
|
24 |
48 |
24 |
6–2/0 |
125 |
8 |
|||||
|
30 |
60 |
30 |
6–2/0 |
125 |
10 |
|||||
|
125 A |
24 |
48 |
24 |
6–2/0 |
6–1/0 |
125 |
8 |
|||
|
30 |
60 |
30 |
6–2/0 |
125 |
10 |
|||||
|
Convertible
Mains—Factory-installed Main Circuit Breaker |
||||||||||
|
150 A |
30 |
60 |
30 |
4–250 |
225 |
10 |
||||
|
200 A |
20 |
40 |
20 |
4–250 |
225 |
9 |
||||
|
30 |
60 |
30 |
225 |
10 |
||||||
|
40 |
80 |
40 |
225 |
12 |
||||||
|
42 |
84 |
42 |
225 |
12 |
||||||
|
60 |
120 |
60 |
225 |
25 |
||||||
|
225 A |
42 |
84 |
42 |
4–300 |
4–250 |
225 |
12 |
|||
|
Split Bus Plug-on Neutral Load Center—Manual Transfer for use with Temporary Backup Power Source Applications NEMA 1 (indoor) |
||||||||||
|
200 A |
36 |
72 |
36 |
4–250 |
— |
12 |
||||
| Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. | ||||||||||
1Ø, Field-Installed Mains Kits
1Ø Field Installed Main Lug Kits – Use with Convertible Main Load Centers Only
|
Field-Installed Main Type |
Frame Size |
Main [7] Ampere Rating |
Use on Convertible Load Center with Mains Rating |
Cat. No. |
Lug Wire Size [11] AWG/kcmil |
|---|---|---|---|---|---|
|
Main Lugs [12] |
— |
125 A |
100–125 A |
6–2/0 Al or Cu |
|
|
125 A |
100–125 A |
6–4/0 Al or Cu |
|||
|
225 A |
150–225 A |
6–300 Al or Cu |
|||
|
Main Circuit Breaker [13] |
QOM1 |
50 A |
100–125 A |
12–2/0 Al or Cu |
|
|
60 A |
100–125 A |
||||
|
70 A |
100–125 A |
||||
|
80 A |
100–125 A |
||||
|
90 A |
100–125 A |
||||
|
100 A |
100–125 A |
||||
|
110 A |
125 A |
||||
|
125 A |
125 A |
||||
|
QOM2 [14] |
100 A |
150–225 A |
4–300 Al or Cu |
||
|
125 A |
150–225 A |
||||
|
150 A |
150–225 A |
||||
|
175 A |
200–225 A |
||||
|
200 A |
200–225 A |
||||
|
225 A |
225 A |
HOM Plug-on Neutral Load Centers with Qwik-Grip
1Ø3W—120/240 Vac Indoor—UL Listed
The Square D Homeline plug-on neutral load centers with Qwik-Grip simplify rough-in by eliminating the need to remove knockouts, install wire connectors, and blindly pull wire into the load center. A quick bend of the wire using the wire bend guide on the Qwik-Grip insert and the wire slides into the slot. Once inserted, the Qwik-Grip shield snaps on to keep the wire behind the router for a secure, code-compliant installation.
Plug-on Neutral Load Centers with Qwik-Grip (Compatible with HOM Plug-on Circuit Breakers and HOM Plug-on Neutral Circuit Breakers)
|
Main Ratings |
Spaces |
Max. 1P Circuits |
Max. Tandem Circuit Breakers |
Load Center Box, Interior and Cover |
Main Wire Size AWG/kcmil |
Bus Rating |
Equipment Ground Bar Kit |
Box |
||
|---|---|---|---|---|---|---|---|---|---|---|
|
Al |
Cu |
|||||||||
|
I N D O O R |
125 A |
24 |
48 |
24 |
6–2/0 |
6–1/0 |
125 |
8Q |
||
|
30 |
60 |
30 |
6–2/0 |
6–2/0 |
125 |
10Q |
||||
|
Convertible Mains—Factory-Installed Main Lugs, 10 kA Short Circuit Current Rating— QOM2 Main Frame Size, Convertible to Main Circuit Breaker |
||||||||||
|
225 A |
30 |
60 |
30 |
4–250 |
225 |
10Q |
||||
|
40 |
80 |
40 |
4–250 |
225 |
12Q |
|||||
|
42 |
84 |
42 |
4–250 |
225 |
12Q |
|||||
|
Convertible Mains—Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating— QOM2 Main Circuit Breaker Frame Size, Convertible to Main Lugs or Main Circuit Breaker |
||||||||||
|
200 A |
30 |
60 |
30 |
4–250 |
225 |
PK23GTA (Order separately) |
10Q |
|||
|
40 |
80 |
40 |
4–250 |
225 |
PK27GTA (Order separately) |
12Q |
||||
|
42 |
84 |
42 |
HOM4284M200PQC OBS |
4–250 |
225 |
PK27GTA (Order separately) |
12Q |
|||
|
OBS This product is obsolete. |
||||||||||
Homeline Service Upgrade Load Centers
1Ø3W—120/240 Vac Special Applications—UL Listed
Service Upgrade Load Centers with Removable End Walls
(Compatible with HOM Plug-on Circuit Breakers and HOM Plug-on Neutral
Circuit Breakers)
|
Mains Rating |
Spaces |
Max. 1P Circuits [1] |
Max. Tandem Circuit Breakers |
Load Center Box and Interior |
Extra Long Cover with Door (Order Separately) |
Main Wire Size AWG / Kcmil |
Bus Rating |
Equipment Ground
Bar Kit |
Box No. [15] |
|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Flush |
Surface |
Al |
Cu |
|||||||||
|
Convertible Mains—Factory-Installed
Main Circuit Breaker—22KA |
||||||||||||
|
INDOOR |
200 A |
30 |
60 |
30 |
HOM3060M200PCEP OBS [16] |
— |
4-250 |
225 |
10 |
|||
|
OBS This product is obsolete. |
||||||||||||