Value Packs
Class 1130, 1170 / Refer to Catalog 1100CT0501
Plug-on Neutral Indoor Load Center Value Packs
Plug-on Neutral Indoor Load Center Value Packs (Compatible with Plug-on and Plug-on Neutral Circuit Breakers)
|
Mains |
Spaces |
Max.
1P |
Max. |
Load Center |
Equipment |
Main |
Bus Rating |
Box |
||
---|---|---|---|---|---|---|---|---|---|---|---|
Cat. No. |
Included Load Center/Circuit Breakers |
Cat. No. |
|||||||||
I N D O O R |
QO (Accepts Only QO Plug-On Circuit Breakers) QO—Copper Bus; Convertible Mains—Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating Convertible appropriate to Main Lugs (See 1Ø, Field-Installed Main Lugs Kits) or QOM Main Circuit Breaker (See 1Ø, Field-Installed Main Circuit Breaker Kits) |
||||||||||
125 A |
24 |
34 |
10 |
(1) QO124L125PGC, (3) QO120, (2) QO230 |
6–2/0 |
125 |
7 |
||||
225 A |
42 |
52 |
10 |
QO142L225PGCVP OBS |
(1) QO142L225PGC, (3) QO120, (2) QO230 |
4–300 |
— |
11 |
|||
Convertible Mains—Factory-Installed
Main Circuit Breaker, |
|||||||||||
100 A |
24 |
34 |
10 |
(1) QO124M100PC, (3) QO120, (2) QO230 |
6–2/0 |
125 |
7 |
||||
32 |
38 |
6 |
(1) QO132M100PC, (3) QO120, (2) QO230 |
6–2/0 |
125 |
8 |
|||||
200 A |
42 |
52 |
10 |
(1) QO142M200PC, (3) QO120, (2) QO230 |
4–300 |
225 |
11 |
||||
42 |
52 |
10 |
QO142M200PCAFVP OBS |
(1) QO142M200PC, (3) QO120, (2) QO230, (3) QO115PCAFI |
— |
11 |
|||||
Homeline (Accepts Only HOM Plug-On Circuit Breakers); Convertible Mains—Factory-Installed Main Lugs, 10 kA Short Circuit Current Rating Convertible to appropriate QOM 22 kA Short Circuit Current Rating Main Circuit Breaker (See 1Ø3W—120/240 Vac—UL Listed) |
|||||||||||
125 A |
12 |
24 |
12 |
(1) HOM1224L125PGC, (2) HOM120 |
6–2/0 |
6–1 |
125 |
6 |
|||
225 A |
30 |
60 |
30 |
(1) HOM3060L225PGC, (3) HOM120, (2) HOM230 |
4–300 |
4–250 |
225 |
10 |
|||
Convertible Mains—Factory-Installed
Main Circuit Breaker, |
|||||||||||
100 A |
20 |
40 |
20 |
(1) HOM2040M100PC, (2) HOM120, (1) HOM230 |
6–1 |
6–3 |
125 |
7 |
|||
20 |
40 |
20 |
(1) HOM2040M100PC, (2) HOM120, (1) HOM230, (1) HOM115PCAFI |
6–1 |
6–3 |
125 |
7 |
||||
24 |
48 |
24 |
(1) HOM2448M100PC, (3) HOM120, (2) HOM230 |
6–2/0 |
6–1/0 |
125 |
8 |
||||
150 A |
30 |
30 |
30 |
(1) HOM3060M150PC, (3) HOM120, (2) HOM230 |
4–250 |
225 |
10 |
||||
200 A |
20 |
40 |
20 |
(1) HOM2040M200PC, (3) HOM120, (2) HOM230 |
4–250 |
225 |
9 |
||||
30 |
60 |
30 |
(1) HOM3060M200PC, (3) HOM120, (2) HOM230 |
225 |
10 |
||||||
30 |
60 |
30 |
(1) HOM3060M200PC, (3) HOM120, (2) HOM230, (1) HOM115PCAFI |
225 |
10 |
||||||
30 |
60 |
30 |
(1) HOM3060M200PC, (3) HOM120, (2) HOM230, (3) HOM115PCAFI |
225 |
10 |
||||||
40 |
80 |
40 |
(1) HOM4080M200PC, (3) HOM120, (2) HOM230 |
225 |
12 |
||||||
40 |
80 |
40 |
(1) HOM4080M200PC, (3) HOM120, (2) HOM230, (1) HOM115PCAFI |
225 |
12 |
||||||
40 |
80 |
40 |
(1) HOM4080M200PC, (3) HOM120, (2) HOM230, (3) HOM115PCAFI |
225 |
12 |
||||||
OBS This product is obsolete. |
Plug-on Neutral with Qwik-Grip Indoor Load Center Value Packs (Compatible with Plug-on and Plug-on Neutral Breakers)
|
Main Ratings |
Spaces |
Max. 1P Circuits |
Max. |
Load Center |
Equipment |
Main |
Bus Rating |
Box |
||
---|---|---|---|---|---|---|---|---|---|---|---|
Cat. No. |
Included Load Center/Circuit Breakers |
Cat. No. |
|||||||||
I N D O O R |
QO Convertible Mains—Factory-Installed Main Lugs, up to 65 kA Short Circuit Current Rating—Copper Bus, QOM1 Main Frame Size, Convertible to Main Circuit Breaker |
||||||||||
125 A |
24 |
34 |
10 |
QO124L125PQGCVP OBS |
(1) QO124L125PQGC, (3) QO120, (2) QO230 and (1) PKQGA Qwik-Grip assembly kit |
Included |
6–2/0 |
— |
7Q |
||
QO Convertible Mains—Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating—Copper Bus, QOM2 Main Frame Size, Convertible to Main Lugs or Main Circuit Breaker |
|||||||||||
200 A |
42 |
52 |
10 |
(1) QO142M200PQC, (3) QO120, (2) QO230 and (1) PKQGA Qwik-Grip assembly kit |
(Order separately) |
4–250 |
225 |
11Q |
|||
Homeline Convertible Mains—Factory-Installed Main Circuit Breaker, 22kA Short Circuit Current Rating—Copper Bus, QOM1 Main Frame Size, Convertible to Main Lugs or Main Circuit Breaker |
|||||||||||
100 A |
20 |
40 |
20 |
(1) HOM2040M100PQC, (2) HOM120, (1) HOM230 and (1) PKQGA Qwik-Grip assembly kit |
(Order separately) |
6–2/0 |
6–1 |
125 |
7Q |
||
200 A |
30 |
60 |
30 |
(1) HOM3060M200PQC, (3) HOM120, (2) HOM230 and (1) PKQGA Qwik-Grip assembly kit |
(Order separately) |
4–250 |
225 |
10Q |
|||
40 |
80 |
40 |
(1) HOM4080M200PQC, (2) HOM120, (1) HOM230 and (1) PKQGA Qwik-Grip assembly kit |
(Order separately) |
4–250 |
225 |
12Q |
||||
OBS This product is obsolete. |
Plug-on Neutral Rainproof Load Center Value Packs (Compatible with Plug-on and Plug-on Neutral Circuit Breakers)
Main |
Spaces |
Max. 1P Circuits |
Max. |
Load Center |
Equipment |
Main |
Bus Rating |
Box |
|||
---|---|---|---|---|---|---|---|---|---|---|---|
Cat. No. |
Included Load Center/Circuit Breakers |
Cat. No. |
|||||||||
R A I N P R O O F |
Homeline (Accepts Only HOM Plug-On Circuit Breakers) Convertible Mains—Factory-Installed
Main Circuit Breaker, |
||||||||||
125 A |
12 |
24 |
12 |
(1) HOM1224M125PRB, (3) HOM120, (2) HOM230 |
6–2/0 |
6–1 |
125 |
3R |
|||
200 A |
30 |
60 |
30 |
(1) HOM3060M200PRB, (3) HOM120, (2) HOM230 |
4–250 |
225 |
7R |