The following tables list the Analog Input objects along with the units and default COV value for each object (if applicable).
Real-time measurements
Object ID | Object name | Units | Default COV | Description |
---|---|---|---|---|
3000 |
Current - Ph A |
A |
50 |
Current phase A |
3002 |
Current - Ph B |
A |
50 |
Current phase B |
3004 |
Current - Ph C |
A |
50 |
Current phase C |
3006 |
Current - Neutral |
A |
50 |
Neutral current |
3008 |
Current - Ground |
A |
50 |
Ground current |
3010 |
Current - Avg |
A |
50 |
Current average |
3012 |
Current Unb - Ph A |
% |
20 |
Current unbalance phase A |
3014 |
Current Unb - Ph B |
% |
20 |
Current unbalance phase B |
3016 |
Current Unb - Ph C |
% |
20 |
Current unbalance phase C |
3018 |
Current Unb - Worst |
% |
20 |
Current unbalance worst |
3020 |
Voltage - A-B |
V |
10 |
Voltage A-B |
3022 |
Voltage - B-C |
V |
10 |
Voltage B-C |
3024 |
Voltage - C-A |
V |
10 |
Voltage C-A |
3026 |
Voltage - Avg L-L |
V |
10 |
Voltage L-L Avg |
3028 |
Voltage - A-N |
V |
10 |
Voltage A-N |
3030 |
Voltage - B-N |
V |
10 |
Voltage B-N |
3032 |
Voltage - C-N |
V |
10 |
Voltage C-N |
3036 |
Voltage - Avg L-N |
V |
10 |
Voltage L-N Avg |
3038 |
Voltage Unb - A-B |
% |
20 |
Voltage unbalance A-B |
3040 |
Voltage Unb - B-C |
% |
20 |
Voltage unbalance B-C |
3042 |
Voltage Unb - C-A |
% |
20 |
Voltage unbalance C-A |
3044 |
Voltage Unb - Worst L-L |
% |
20 |
Voltage unbalance L-L worst |
3046 |
Voltage Unb - A-N |
% |
20 |
Voltage unbalance A-N |
3048 |
Voltage Unb - B-N |
% |
20 |
Voltage unbalance B-N |
3050 |
Voltage Unb - C-N |
% |
20 |
Voltage unbalance C-N |
3052 |
Voltage Unb - Worst L-N |
% |
20 |
Voltage unbalance L-N worst |
3110 |
Frequency |
Hz |
10 |
Frequency |
Power and power factor
Object ID | Object name | Units | Default COV | Description |
---|---|---|---|---|
3054 |
Active Power - Ph A |
kW |
10 |
Active power phase A |
3056 |
Active Power - Ph B |
kW |
10 |
Active power phase B |
3058 |
Active Power - Ph C |
kW |
10 |
Active power phase C |
3060 |
Active Power - Total |
kW |
10 |
Active power total |
3062 |
Reactive Power - Ph A |
kVAR |
10 |
Reactive power phase A |
3064 |
Reactive Power - Ph B |
kVAR |
10 |
Reactive power phase B |
3066 |
Reactive Power - Ph C |
kVAR |
10 |
Reactive power phase C |
3068 |
Reactive Power - Total |
kVAR |
10 |
Reactive power total |
3070 |
Apparent Power - Ph A |
kVA |
10 |
Apparent power phase A |
3072 |
Apparent Power - Ph B |
kVA |
10 |
Apparent power phase B |
3074 |
Apparent Power - Ph C |
kVA |
10 |
Apparent power phase C |
3076 |
Apparent Power - Total |
kVA |
10 |
Apparent power total |
3078 |
Power Factor - Ph A |
— |
0.2 |
Power factor phase A |
3080 |
Power Factor - Ph B |
— |
0.2 |
Power factor phase B |
3082 |
Power Factor - Ph C |
— |
0.2 |
Power factor phase C |
3084 |
Power Factor - Total |
— |
0.2 |
Power Factor Total |
Energy and energy by tariff measurements
Object ID | Object name | Units | Default COV | Description |
---|---|---|---|---|
2700 |
Active Energy Delvd |
kWh |
100 |
Active energy delivered |
2702 |
Active Energy Rcvd |
kWh |
100 |
Active energy received |
2704 |
Active Energy Delvd + Rcvd |
kWh |
100 |
Active energy delivered + received |
2706 |
Active Energy Delvd - Rcvd |
kWh |
100 |
Active energy delivered – received |
2708 |
Reactive Energy Delvd |
kVARh |
100 |
Reactive energy delivered |
2710 |
Reactive Energy Rcvd |
kVARh |
100 |
Reactive energy received |
2712 |
Reactive Energy Delvd + Rcvd |
kVARh |
100 |
Reactive energy delivered + received |
2714 |
Reactive Energy Delvd - Rcvd |
kVARh |
100 |
Reactive energy delivered – received |
2716 |
Apparent Energy Delvd |
kVAh |
100 |
Apparent energy delivered |
2718 |
Apparent Energy Rcvd |
kVAh |
100 |
Apparent energy received |
2720 |
Apparent Energy Delvd + Rcvd |
kVAh |
100 |
Apparent energy delivered + received |
2722 |
Apparent Energy Delvd - Rcvd |
kVAh |
100 |
Apparent energy delivered – received |
4191 |
Applicable Tariff Energy Rate |
— |
1 |
Denotes the active tariff: 0 = Multi Tariff feature is disabled 1 = tariff 1 active 2 = tariff 2 active 3 = tariff 3 active 4 = tariff 4 active |
4800 |
Active Energy Delvd (Tariff 1) |
kWh |
100 |
Tariff 1 active energy import |
4802 |
Active Energy Delvd (Tariff 2) |
kWh |
100 |
Tariff 2 active energy import |
4804 |
Active Energy Delvd (Tariff 3) |
kWh |
100 |
Tariff 3 active energy import |
4806 |
Active Energy Delvd (Tariff 4) |
kWh |
100 |
Tariff 4 active energy import |
Power demand
Object ID | Object name | Units | Default COV | Description |
---|---|---|---|---|
3764 |
Dmd - Active Power Last |
kW |
10 |
Demand - Active power last |
3766 |
Dmd - Active Power Present |
kW |
10 |
Demand - Active power present |
3768 |
Dmd - Active Power Pred |
kW |
10 |
Demand - Active power predicted |
3770 |
Dmd - Active Power Peak |
kW |
10 |
Demand - Active power peak |
3780 |
Dmd - Reactive Power Last |
kVAR |
10 |
Demand - Reactive power last |
3782 |
Dmd - Reactive Power Present |
kVAR |
10 |
Demand - Reactive power present |
3784 |
Dmd - Reactive Power Pred |
kVAR |
10 |
Demand - Reactive power predicted |
3786 |
Dmd - Reactive Power Peak |
kVAR |
10 |
Demand - Reactive power peak |
3796 |
Dmd - Apparent Power Last |
kVA |
10 |
Demand - Apparent power last |
3798 |
Dmd - Apparent Power Present |
kVA |
10 |
Demand - Apparent power present |
3800 |
Dmd - Apparent Power Pred |
kVA |
10 |
Demand - Apparent power predicted |
3802 |
Dmd - Apparent Power Peak |
kVA |
10 |
Demand - Apparent power peak |
Current demand
Object ID | Object name | Units | Default COV | Description |
---|---|---|---|---|
3876 |
Dmd - Average Current Last |
A |
10 |
Demand - Average current last |
3878 |
Dmd - Avg Current Present |
A |
10 |
Demand - Average current present |
3880 |
Dmd - Average Current Pred |
A |
10 |
Demand - Average current predicted |
3882 |
Dmd - Average Current Peak |
A |
10 |
Demand - Average current peak |
Power quality
Object ID | Object name | Units | Default COV | Description |
---|---|---|---|---|
21300 |
THD Current - Ph A |
% |
20 |
THD Current A |
21302 |
THD Current - Ph B |
% |
20 |
THD Current B |
21304 |
THD Current - Ph C |
% |
20 |
THD Current C |
21306 |
THD Current - Ph N |
% |
20 |
THD Current N |
21308 |
THD Current - Ph G |
% |
20 |
THD Current G |
21310 |
thd Current - Ph A |
% |
20 |
thd Current A |
21312 |
thd Current - Ph B |
% |
20 |
thd Current B |
21314 |
thd Current - Ph C |
% |
20 |
thd Current C |
21316 |
thd Current - Ph N |
% |
20 |
thd Current N |
21318 |
thd Current - Ph G |
% |
20 |
thd Current G |
21320 |
Total Dmd Distortion |
% |
20 |
Total Demand Distortion |
21322 |
THD Voltage - A-B |
% |
20 |
THD Voltage A-B |
21324 |
THD Voltage - B-C |
% |
20 |
THD Voltage B-C |
21326 |
THD Voltage - C-A |
% |
20 |
THD Voltage C-A |
21328 |
THD Voltage - Avg L-L |
% |
20 |
THD Voltage L-L |
21330 |
THD Voltage - A-N |
% |
20 |
THD Voltage A-N |
21332 |
THD Voltage - B–N |
% |
20 |
THD Voltage B-N |
21334 |
THD Voltage - C-N |
% |
20 |
THD Voltage C-N |
21338 |
THD Voltage - Avg L-N |
% |
20 |
THD Voltage L-N |
21340 |
thd Voltage - A-B |
% |
20 |
thd Voltage A-B |
21342 |
thd Voltage - B-C |
% |
20 |
thd Voltage B-C |
21344 |
thd Voltage - C-A |
% |
20 |
thd Voltage C-A |
21346 |
thd Voltage - Avg L-L |
% |
20 |
thd Voltage L-L |
21348 |
thd Voltage - A-N |
% |
20 |
thd Voltage A-N |
21350 |
thd Voltage - B-N |
% |
20 |
thd Voltage B-N |
21352 |
thd Voltage - C-N |
% |
20 |
thd Voltage C-N |
21356 |
thd Voltage - Avg L-N |
% |
20 |
thd Voltage L-N |
Meter information
The following table lists Analog Input objects that provide information about the meter and its configuration.
Object ID | Object name | Units | Default COV | Description |
---|---|---|---|---|
2000 |
Time since last meter power up |
Seconds |
604800 |
Time since the meter was last powered up |
2004 |
Meter operation timer |
Seconds |
604800 |
Total meter operation time |
2014 |
Number of phases |
— |
1 |
Number of phases 1, 3 |
2015 |
Number of wires |
— |
1 |
Number of wires 2, 3, 4 |
2017 |
Nominal frequency |
Hz |
1 |
Nominal frequency 50, 60 |
2025 |
Number of VTs |
— |
1 |
Number of VTs 0, 2, 3 |
2026 |
VT primary |
V |
1 |
VT Primary |
2028 |
VT secondary |
V |
1 |
VT Secondary |
2029 |
Number of CTs |
— |
1 |
Number of CTs 1, 2, 3 |
2030 |
CT primary |
A |
1 |
CT Primary |
2031 |
CT secondary |
A |
1 |
CT Secondary |