TeSys™ Motor Starters and Protectors
Refer to Catalog MKTED210011EN
TeSys™ Power Motor Circuit Breakers
The TeSys™ Power Motor Circuit Breakers family of products provide efficient motor control and protection solutions up to 520 amps. There are a variety of UL approved applications that enable specified configurations for use as a manual starter, motor disconnect, independent branch short-circuit protection, motor overload protection, or for use with a motor controller such as a contactor to build a complete motor control circuit. Certain configurations are approved for group motor applications as well. Refer to the following selection tables for application information, as well as the Motor Control Solutions for the North American Market data bulletin (8536DB0901) for additional information.
The GV2P (up to 32 amps) and GV3P (up to 65 amps) is rated to UL 60947-4-1 as a motor starter, and also possess Type E ratings for manual switching applications. These devices can be combined with a specified TeSys Deca contactor as a Type F combination motor controller (with specified line side spacer/accessories), with SCCR up to 100kA.
The GV2ME (up to 32 amps) combined with a specified TeSys Deca contactor is ideal for group motor applications.
The TeSys island load management starters are approved for use with TeSys GV2P and GV3P devices as a group motor arrangement. See selection table for application specifics.
The GV4PB, GV5PB, and GV6PB are motor protective circuit breakers rated to UL 489, are approved as branch circuit protection (no line side spacer required) and include motor overload protection. A full motor branch circuit is completed with the addition of a contactor, providing a compact two-component solution up to 520 motor full load amps. Pre-trip alarm accessories can be applied to these units to help anticipate and resolve issues, minimizing operator or maintenance interaction.
GV2, GV3 Manual Motor Protectors (UL 60947-4-1)
Thermal Setting (A) |
Maximum Horsepower Ratings |
GV2ME push button[1] |
GV2/3P rotary handle |
||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Single-Phase |
Three-Phase |
||||||||||
115 V |
200 V |
230 V |
115 V |
200 V |
230 V |
460 V |
575 V |
Catalog |
Catalog |
||
GV2P GV2ME |
0.10–0.16 |
— |
— |
— |
— |
— |
— |
— |
— |
||
0.16–0.25 |
— |
— |
— |
— |
— |
— |
— |
— |
|||
0.25–0.40 |
— |
— |
— |
— |
— |
— |
— |
— |
|||
0.40–0.63 |
— |
— |
— |
— |
— |
— |
— |
— |
|||
0.63–1 |
— |
— |
— |
— |
— |
— |
— |
1/2 |
|||
1–1.6 |
— |
— |
1/10 |
— |
— |
— |
3/4 |
3/4 |
|||
1.6–2.5 |
— |
1/6 |
1/6 |
— |
1/2 |
1/2 |
1 |
1.5 |
|||
2.5–4 |
1/8 |
1/4 |
1/3 |
— |
3/4 |
3/4 |
2 |
3 |
|||
4–6.3 |
1/4 |
1/2 |
1/2 |
3/4 |
1 |
1.5 |
3 |
5 |
|||
6–10 |
1/2 |
1 |
1.5 |
1 |
2 |
3 |
5 |
7.5 |
|||
9–14 |
3/4 |
2 |
2 |
2 |
3 |
3 |
10 |
10 |
|||
13–18 |
1 |
2 |
3 |
2 |
5 |
5 |
10 |
15 |
|||
17–23 |
1.5 |
3 |
3 |
3 |
5 |
7.5 |
15 |
20 |
|||
20–25 |
2 |
— |
— |
— |
7.5 |
7.5 |
15 |
20 |
|||
24–32 |
2 |
5 |
5 |
5 |
7.5 |
10 |
20 |
25 |
|||
9–13 |
1/2 |
— |
1.5 |
— |
3 |
3 |
7.5 |
10 |
— |
||
12–18 |
3/4 |
— |
2 |
— |
3 |
5 |
7.5 |
10 |
— |
||
17–25 |
1.5 |
— |
3 |
— |
5 |
7.5 |
15 |
20 |
— |
||
23–32 |
2 |
— |
3 |
— |
7.5 |
7.5 |
20 |
25 |
— |
||
30–40 |
3 |
— |
5 |
— |
10 |
10 |
25 |
30 |
— |
||
37–50 |
3 |
— |
7.5 |
— |
10 |
10 |
30 |
40 |
— |
||
48–65 |
3 |
— |
10 |
— |
15 |
15 |
40 |
50 |
— |
GV4, GV5, GV6 UL 489 Motor Protective Circuit Breakers
Motor FLA Dial Range |
Interrupting Rating: |
Interrupting Rating: |
Interrupting Rating: |
---|---|---|---|
0.8 ... 2 | — | ||
1.4 ... 3.5 | — | ||
2.9 ... 7 | — | ||
5 ... 12.5 | — | ||
10 ... 25 | |||
20 ... 50 | |||
40 ... 80 | |||
65 ... 115 | |||
58 ... 130 | — | ||
114 ... 217 | — | ||
190 ... 348 | — | ||
312 ... 520 | — |