Push Buttons and Pilot Lights
Refer to Catalogs DIA5ED2121212EN*, DIA5ED2121213EN**, DIA5ED2120503EN***, and 9001CT1103****
Push Button Selection Guide
Family |
XB4 |
XB5 |
XB7 |
9001K |
9001SK |
9001KX |
---|---|---|---|---|---|---|
Type of Product |
*22 mm Push Button |
**22 mm Push Button (plastic) |
***22mm Push Button (plastic) |
****30 mm Push Button |
****30 mm Push Button (plastic) |
****30 mm Push Button |
Mounting Hole Diameter |
22.5 mm |
22.5 mm |
22.5 mm |
31 mm |
31 mm |
31 mm |
Approvals |
UL Listed File E164353, CCN NKCR UL Recognized File E164353. CCN NKCR2 |
UL Listed File E164353, UL Recognized File E164353., CCN NKCR2 |
UL File E164353, CCN NKCR |
UL File E78403. CCN NKCR |
UL File E78403. CCN NKCR |
UL File E78403. CCN NKCR |
CSA File LR44087. Class 3211-03 |
CSA File LR44087. Class 3211-03 |
CSA File LR44087-122 Class 3211-03 |
CSA File LR25490. Class 3211-03 |
CSA File LR25490. Class 3211-03 |
CSA File LR25490. Class 3211-03 |
|
Conforming to Standards |
CE Marked |
CE Marked |
CE Marked |
CE Marked |
CE Marked |
CE Marked |
EN/IEC 60947-1, EN/IEC 60947-5-1, EN/IEC 60947-5-4, EN/IEC 60947-5-5 |
EN/IEC 60947-1, EN/IEC 60947-5-1, EN/IEC 60947-5-4, EN/IEC 60947-5-5 |
EN/IEC 60947-1, EN/IEC 60947-5-1 for push buttons, pilot lights, illuminated push buttons and selector switches EN/IEC 60947-1, EN/IEC 60947-5-1, EN/IEC 60947-5-5, |
EN/IEC 60947-1 |
EN/IEC 60947-1 |
EN/IEC 60947-1 |
|
EN/IEC 60204-1 and EN/ISO 13850: 2006 (trigger action and mechanical latching emergency stop push buttons) |
EN/IEC 60204-1 and EN/ISO 13850: 2006 (trigger action and mechanical latching emergency stop push button). |
EN/IEC 60204-1 and EN/ISO 13850 for Emergency Stop trigger action push buttons |
EN/IEC60947-5-1 |
EN/IEC60947-5-1 |
EN/IEC60947-5-1 |
|
EN/IEC 60364-5-53 (emergency switching of mechanical latching push buttons) |
EN/IEC 60364-5-53 (emergency switching of mechanical latching push buttons) |
EN/IEC60947-5-4 |
EN/IEC60947-5-4 |
EN/IEC60947-5-4 |
||
— |
EN81-1 (emergency stop trigger action and mechanical latching push buttons with mechanical state indicator) |
|||||
JIS C 4520 |
JIS C 4520 |
JIS C 4520 and 852 |
JIS C 4520 and 852 |
JIS C 4520 and 852 |
||
UL 508 |
UL 508 |
UL 508 |
UL 508 |
UL 508 |
UL 508 |
|
CSA C22.2 No.14 |
CSA C22.-2 No.14 |
CSA C22 No.14 |
CSA C22.2 No.14 |
CSA C22.2 No.14 |
CSA C22.2 No.14 |
|
GOST |
GOST |
|||||
CCC |
CCC |
CCC | ||||
GB 14048.5 for all XB7 range | ||||||
Degree of Protection |
IP65, IP69, IP69K |
IP65, IP69, IP69K |
IP54, IP65 |
IP65 |
IP65 |
IP66 |
IP66 for booted |
IP66 for booted |
— |
— |
— |
— |
|
NEMA 1, 2, 3, 4, 4X, 12, 13 |
NEMA 1, 2, 3, 3R, 4, 4X, 12, 13 |
NEMA 3, 4, 12 |
NEMA 1, 2, 3, 3R, 4, 12, 13 |
NEMA 1, 2, 3, 3R, 4, 4X, 12, 13 | NEMA 1, 2, 3, 3R, 4, 12, 13 | |
Operating Temperature F° (C°) |
-40 to 158 (-40 to 70) |
-40 to 158 (-40 to 70) |
-13 to 158 (-25 to 70) |
-22 to 140 (-30 to 60) |
-22 to 140 (-30 to 60) |
-22 to 140 (-30 to 60) |
Storage Temperature F° (C°) |
-40 to 158 (-40 to 70) |
-40 to 158 (-40 to 70) |
-40 to 158 (-40 to 70) |
-40 to 158 (-40 to 70) |
-40 to 158 (-40 to 70) |
-40 to 158 (-40 to 70) |
Electric Shock Protection |
Class I |
Class I |
— |
Class II |
Class II |
Class II |
Electrical Consumption |
||||||
LED |
24 Vac/Vdc: 18 mA |
24 Vac/Vdc: 18 mA |
Illuminated Push Buttons: Pilot Lights |
Incandescent and LED bulbs. |
Incandescent and LED bulbs. |
Incandescent |
120 Vac: 14 mA |
120 Vac: 14 mA |
|||||
240 Vac: 14 mA |
240 Vac: 14 mA |
|||||
Rated Operational Characteristics |
AC-15; B600 Ue = 600 Vac and le = 1.2 A Ue = 240 Vac and le = 3A Ue = 120 Vac and le = 6A Continuous 10 A |
AC-15; B600 Ue = 600 Vac and le = 1.2 A Ue = 240 Vac and le = 3 A Ue = 120 Vac and le = 6 A Continuous 10 A |
AC-14; D300 Ue = 240 Vac and le = 0.3A Ue = 120 Vac and le = 0.6A Continuous 4 A |
AC-15; A600 Continuous 10 A |
AC-15; A600 Continuous 10 A |
AC-15; A600 Continuous 10 A |
DC-13; Q600 Ue = 600 Vdc and Ue = 250 Vdc and Ue = 125 Vdc and |
DC-13; Q600 Ue = 600 Vdc and Ue = 250Vdc and Ue = 125 Vdc
and |
DC-13; R300 Ue = 250 Vdc and le = 0.1A Ue = 125 Vdc and le = 0.22A |
DC-13; Q600 Ue = 600 Vdc and Ue = 250 Vdc and Ue = 125 Vdc
and |
DC-13; Q600 Ue = 600 Vdc and Ue = 250 Vdc and Ue = 125 Vdc
and |
DC-13; Q600 Ue = 600 Vdc and Ue = 250 Vdc and Ue = 125 Vdc
and |
|
Connection Type |
IP20 Fingersafe Screw or Spring Terminal |
Screw and captive clamp terminal connections Faston clip connections (pilot lights) |
IP20 Fingersafe Screw Terminal |
|||
Screw Terminal: |
Spring Terminal: |
|||||
Cable Size |
1 x 24 AWG (0.22 mm²) min. 2 x 14 AWG (2.5 mm²) max. 2 x 16 AWG (1.5 mm²) max. |
1 x 24 AWG (0.22 mm²) min. 2 x 14 AWG (2.5 mm²) max. 2 x 16 AWG (1.5 mm²) max. |
1 x 24 AWG (0.22 mm²) min. 2 x 16 AWG (1.5 mm²) max |
1 x 24 AWG (0.22 mm²) min. 2 x 16 AWG (1.5 mm²) max |
1 x 24 AWG (0.2 2mm²) min. 2 x 16 AWG (1.5 mm²) max |
|
Digest Location |