9001 K Selector Switches
Class 9001 / Refer to Catalog 9001CT1103
9001K 2-Position Selector Switches
2-Position Selector Switches
Contact Block Required |
1 — Contact Closed 0 — Contact Open |
|||||||||
---|---|---|---|---|---|---|---|---|---|---|
Contact
Block |
Quantity
and Type |
Mount
on Side |
||||||||
KA1 |
or |
KA3 |
KA1 |
or |
KA3 |
1 0 |
0 1 |
|||
KA2 |
KA2 |
0 1 |
1 0 |
|||||||
KA1 |
or |
KA3 |
KA1 |
or |
KA3 |
1 0 |
0 1 |
|||
KA2 |
KA2 |
0 1 |
1 0 |
|||||||
For cam, see Type K, KX, and SK Selector Switch Guide. |
E |
D |
||||||||
Non-Illuminated Operators |
Cat. No. [1] |
Cat. No. [1] |
||||||||
Manual Return [2], Operator Only (without contact blocks) |
||||||||||
Without Knob |
||||||||||
With Knob (select style and color from Selector Switch Assembly Codes) [3] |
KS11♦ |
KS12♦ |
||||||||
Key Operated with E10 Key (Code1,2,3) [3] |
KS11K♦ |
KS12K♦ |
||||||||
Operator with Contact Blocks and Standard black knob |
||||||||||
With 1 KA1 on Side #2 |
KS11BH13 |
— |
||||||||
With 1 KA1 on Side #1 |
— |
|||||||||
With 1 KA1 on Side #1 and 1 KA1 on side #2 |
— |
|||||||||
Spring Return from Left [2], Operator Only (without contact blocks) |
||||||||||
Without Knob |
KS25 |
— |
||||||||
With Knob (select style and color from Selector Switch Assembly Codes) [3] |
KS25♦ |
— |
||||||||
Key Operated with E10 Key (Code 2 only) [4] |
KS25K2 |
— |
||||||||
Spring Return from Right [2], Operator Only (without contact blocks) |
||||||||||
Without Knob |
— |
|||||||||
With Knob (select style and color from Selector Switch Assembly Codes) [3] |
— |
KS34♦ |
||||||||
Key Operated with E10 Key (Code 1 only) |
— |
|||||||||
Illuminated Operators |
Cat. No. [1] |
Cat. No. [1] |
||||||||
Manual Return [2], Operator Only (without contact blocks) |
||||||||||
Without Knob, 110-120V 50-60 Hz Transformer |
||||||||||
With Standard Red Knob, 110-120V 50-60 Hz Transformer |
||||||||||
With Other Color Knob and other voltage Light Module [5]. [3] |
K11J■♦ |
K12J■♦ |
||||||||
Spring Return from Left [2], Operator Only (without contact blocks) |
||||||||||
Without Knob, 110-120V 50-60 Hz Transformer |
— |
|||||||||
With Standard Red Knob, 110-120V 50-60 Hz Transformer |
— |
|||||||||
With Other Color Knob and other voltage Light Module [5]. [3] |
K25J■♦ |
— |
||||||||
Spring Return from Right [2], Operator Only (without contact blocks) |
||||||||||
Without Knob, 110-120V 50-60 Hz Transformer |
— |
|||||||||
With Standard Red Knob, 110-120V 50-60 Hz Transformer |
— |
|||||||||
With Other Color Knob and other voltage Light Module [5]. [3] |
— |
K34J■♦ |
Selector Switch Assembly Code and Knob Cat. No.
Color |
Standard Knob |
Gloved Hand Knob |
||
---|---|---|---|---|
♦ Knob Code |
Cat. No. [1] |
♦ Knob Code |
Cat. No. [1] |
|
Black |
B |
FB |
||
Red |
R |
FR |
||
Green |
G |
FG |
||
Yellow |
Y |
FY |
||
Blue |
L |
FL |
||
White |
W |
FW |
||
Amber |
A |
FA |
||
Clear |
C |
FC |
Key Withdrawl Codes
Code |
Position |
|
1 | Left Only | |
2 | Right Only | |
3 | Left and Right | |
NOTE: To select and order Contact Blocks, Light Modules, Knobs, and Accessories, see Type KA Contact Blocks through Hermetically Sealed Power Reed Contact Blocks. |
9001K 3-Position Selector Switches
3-Position Selector Switches
Contact Block Required |
1 - Contact Closed 0- Contact Open |
||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Contact |
Quantity |
Mount |
|||||||||||||
KA1 |
or |
KA3 |
KA1 |
or |
KA3 |
1 0 0 |
1 0 0 |
0 0 1 |
1 0 0 |
1 0 0 |
1 0 0 |
1 0 0 |
0 1 0 |
1 1 0 |
|
KA2 |
KA2 |
0 1 1 |
0 0 1 |
0 1 0 |
0 1 0 |
0 0 1 |
0 1 1 |
0 1 1 |
1 0 0 |
0 0 1 |
|||||
KA1 |
or |
KA3 |
KA1 |
or |
KA3 |
0 0 1 |
1 0 0 |
0 0 1 |
1 0 0 |
0 1 0 |
0 0 1 |
1 0 1 |
0 0 1 |
0 1 1 |
|
KA2 |
KA2 |
1 1 0 |
0 0 1 |
0 1 0 |
0 1 0 |
0 0 1 |
1 0 0 |
0 1 0 |
0 1 0 |
1 0 0 |
|||||
For
cam, see Type K, KX, and SK Selector Switch Guide. |
B |
C |
D |
E |
F |
G |
J |
L |
M |
||||||
Non-Illuminated Operators [1] |
Cat. No. |
Cat. No. |
Cat. No. |
Cat. No. |
Cat. No. |
Cat. No. |
Cat. No. |
Cat. No. |
Cat. No. |
||||||
Manual Return, Operator Only (without contact blocks) [2] |
|||||||||||||||
Without Knob |
|||||||||||||||
With Knob ♦[6] |
KS42♦ |
KS43♦ |
KS44♦ |
KS45♦ |
KS46♦ |
KS47♦ |
KS49♦ |
KS401♦ |
KS402♦ |
||||||
Key Operated with E10 Key (Code 4 through 10) ▼[7] |
KS42K▼ |
KS43K▼ |
KS44K▼ |
KS45K▼ |
KS46K▼ |
KS47K▼ |
KS49K▼ |
KS401K▼ |
KS402K▼ |
||||||
Operator with Contact Blocks and Standard black knob [8] |
|||||||||||||||
With 1 KA1 on Side #2 (H13) |
|||||||||||||||
With 1 KA1 on Side #1 (H1) |
|||||||||||||||
With 1 KA1 on Side #1 and 1 KA1 on side #2 (H2) |
|||||||||||||||
Spring Return from Left to Center, Operator Only (without contact blocks) [2] |
|||||||||||||||
Without Knob |
|||||||||||||||
With Knob ♦[6] |
KS62♦ |
KS63♦ |
KS64♦ |
KS65♦ |
KS66♦ |
KS67♦ |
KS69♦ |
KS601♦ |
KS602♦ |
||||||
Key Operated with E10 Key (Code 5, 6 or 9 only) ▼[7] |
KS62K▼ |
KS63K▼ |
KS64K▼ |
KS65K▼ |
KS66K▼ |
KS67K▼ |
KS69K▼ |
KS601K▼ |
KS602K▼ |
||||||
Spring Return from Right to Center, Operator Only (without contact blocks) [2] |
|||||||||||||||
Without Knob |
|||||||||||||||
With Knob ♦[6] |
KS72♦ |
KS73♦ |
KS74♦ |
KS75♦ |
KS76♦ |
KS77♦ |
KS79♦ |
KS701♦ |
KS702♦ |
||||||
Key Operated with E10 Key (Code 4, 5 or 7 only) ▼[7] |
KS72K▼ |
KS73K▼ |
KS74K▼ |
KS75K▼ |
KS76K▼ |
KS77K▼ |
KS79K▼ |
KS701K▼ |
KS702K▼ |
||||||
Spring Return from Both Sides to Center, Operator Only (without contact blocks) [2] |
|||||||||||||||
Without Knob |
|||||||||||||||
With Knob ♦[6] |
KS52♦ |
KS53♦ |
KS54♦ |
KS55♦ |
KS56♦ |
KS57♦ |
KS59♦ |
KS501♦ |
KS502♦ |
||||||
Key Operated with E10 Key (Code 4, 5 or 7 only) ▼[7] |
KS52K▼ |
KS53K▼ |
KS54K▼ |
KS55K▼ |
KS56K▼ |
KS57K▼ |
KS59K▼ |
KS501K▼ |
KS502K▼ |
||||||
Illuminated Operators [1] |
Cat. No. |
Cat. No. |
Cat. No. |
Cat. No. |
Cat. No. |
Cat. No. |
Cat. No. |
Cat. No. |
Cat. No. |
||||||
Manual Return, Operator Only (without contact blocks) [2] |
|||||||||||||||
Without Knob, 110-120V 50-60 Hz Transformer |
|||||||||||||||
With Standard Red Knob, 110-120V 50-60 Hz Transformer |
|||||||||||||||
With Other Color Knob and other voltage Light Module ■[9] ♦[6] |
K42J■♦ |
K43J■♦ |
K44J■♦ |
K45J■♦ |
K46J■♦ |
K47J■♦ |
K49J■♦ |
K401J■♦ |
K402J■♦ |
||||||
Spring Return from Left to Center, Operator Only (without contact blocks) [2] |
|||||||||||||||
Without Knob, 110-120V 50-60 Hz Transformer |
|||||||||||||||
With Standard Red Knob, 110-120V 50-60 Hz Transformer |
|||||||||||||||
With Other Color Knob and other voltage Light Module ■[9] ♦[6] |
K62J■♦ |
K63J■♦ |
K64J■♦ |
K65J■♦ |
K66J■♦ |
K67J■♦ |
K69J■♦ |
K601J■♦ |
K602J■♦ |
||||||
Spring Return from Right to Center, Operator Only (without contact blocks) [2] |
|||||||||||||||
Without Knob, 110-120V 50-60 Hz Transformer |
|||||||||||||||
With Standard Red Knob, 110-120V 50-60 Hz Transformer |
|||||||||||||||
With Other Color Knob and other voltage Light Module ■[9] ♦[6] |
K72J■♦ |
K73J■♦ |
K74J■♦ |
K75J■♦ |
K76J■♦ |
K77J■♦ |
K79J■♦ |
K701J■♦ |
K702J■♦ |
||||||
Spring Return from Both Sides to Center, Operator Only (without contact blocks) [2] |
|||||||||||||||
Without Knob, 110-120V 50-60 Hz Transformer |
|||||||||||||||
With Standard Red Knob, 110-120V 50-60 Hz Transformer |
|||||||||||||||
With Other Color Knob and other voltage Light Module ■[9] ♦[6] |
K52J■♦ |
K53J■♦ |
K54J■♦ |
K55J■♦ |
K56J■♦ |
K57J■♦ |
K59J■♦ |
K501J■♦ |
K502J■♦ |
Selector Switch Assembly Code and Knob Cat. No. ♦
Color |
Standard Knob |
Gloved Hand Knob |
||
---|---|---|---|---|
[6] Knob Code |
Cat. No. [1] |
[6] Knob Code |
Cat. No. [1] |
|
Black |
B |
FB |
||
Red |
R |
FR |
||
Green |
G |
FG |
||
Yellow |
Y |
FY |
||
Blue |
L |
FL |
||
White |
W |
FW |
||
Amber |
A |
FA |
||
Clear |
C |
FC |
Key Withdrawal Codes [10]
Code |
Position |
|
---|---|---|
4 |
Left Only |
|
5 |
Center Only |
|
6 |
Right Only |
|
7 |
Left and Center |
|
8 |
Left and Right |
|
9 |
Center and Right |
|
10 |
Left, Center, and Right |
|
NOTE: To select and order Contact Blocks, Light Modules, Knobs, and Accessories, see Type KA Contact Blocks through Hermetically Sealed Power Reed Contact Blocks. |
9001K 4-Position Selector Switches
4-Position Selector Switches
Contact Block Required |
|||||||
---|---|---|---|---|---|---|---|
Contact Block Position |
Quantity
and Type |
Mount
on Side |
1—Contact Closed |
||||
KA1 |
or |
KA3 |
KA1 |
or |
KA3 |
1 0 0 0 |
|
KA2 |
KA2 |
0 0 1 0 |
|||||
KA1 |
or |
KA3 |
KA1 |
or |
KA3 |
0 0 0 1 |
|
KA2 |
KA2 |
0 1 0 0 |
|||||
For cam, see Type K, KX, and SK Selector Switch Guide. |
H |
||||||
Non-Illuminated Operators |
Cat. No. [1] |
||||||
Manual Return [2], Operator Only (without contact blocks) |
|||||||
Without Knob |
|||||||
With Knob♦[11] |
KS88♦ |
||||||
Key Operated with E10 Key (Codes 11, 12, 13, 14, 15) |
KS88K[12] |
||||||
Illuminated Operators |
Cat. No. [1] |
||||||
Manual Return [2], Operator Only (without contact blocks) |
|||||||
Without Knob, 110-120V 50-60 Hz Transformer |
|||||||
With Standard Red Knob, 110-120V 50-60 Hz Transformer |
|||||||
With Other Color Knob and other voltage Light Module ■[13] ♦[11][14] |
K88J■♦ |
Selector Switch Assembly Code and Knob Cat. No.
Color |
Standard Knob |
Gloved Hand Knob |
||
---|---|---|---|---|
Knob Code |
Cat. No. |
Knob Code |
Cat. No. |
|
Black |
B |
FB |
||
Red |
R |
FR |
||
Green |
G |
FG |
||
Yellow |
Y |
FY |
||
Blue |
L |
FL |
||
White |
W |
FW |
||
Amber |
A |
FA |
||
Clear |
C |
FC |
Key Withdrawl Codes
Code |
Position |
|
11 |
1 and 4 |
|
12 |
4 only |
|
13 |
1 only |
|
14 |
1, 2, 3 and 4 |
|
15 |
2, 3, and 4 |
|
NOTE: To select and order Contact Blocks, Light Modules, Knobs, and Accessories, see Type KA Contact Blocks through Hermetically Sealed Power Reed Contact Blocks. |
Potentiometers with Dial Plate
Potentiometers with Dial Plate (not UL listed)—Maximum Voltage 300 Vac
Power |
Description |
Ratings |
Type |
---|---|---|---|
2 W |
Operator Only, for Single Potentiometer |
NEMA 4, 13 |
|
Operator with Single Potentiometer |
Potentiometer Suffixes
Single Potentiometer |
|||
---|---|---|---|
Suffix [15] |
Resistance |
Suffix [15] |
Resistance |
01 |
50 Ω |
07 |
5 kΩ |
02 |
100 Ω |
08 |
10 kΩ |
04 |
500 Ω |
09 |
25 kΩ |
05 |
1 kΩ |
13 |
500 kΩ |
39 |
2 kΩ |
37 |
750 kΩ |
06 |
2.5 kΩ |
14 |
1 MΩ |
Tandem Potentiometer |
|||
Suffix [15] |
Resistance |
||
Front |
Rear |
||
82 |
1 kW |
1 kW |
|
NOTE: Any potentiometer with a shaft 7/8" long and 1/4" diameter may be used with these operators. |