Pendant Stations
Refer to Catalogs DIA5ED2140103EN* and 9001CT1001**
Pendant Station Selection Guide
Family |
ZAR eXL Hoist Compact |
ZAR |
9001BW |
XACA2 |
XACA0 |
---|---|---|---|---|---|
Type of Product |
*Wireless Pendant |
*Wireless Remote |
**2-Button Pendant |
**2-Button Pistol Grip Pendant |
**General Purpose Pendant |
Number of operators |
6 motion, 2 auxilliary |
3, 4, 6, 8, and 10 |
2 |
2 |
2, 3, 4, 6, 8, 12 |
Approvals |
UL/CSA, CE, EAC |
UL, CE |
UL File E78403 CNN NKCR CSA File LR25490 Class 3211-03 |
UL File E164353 CNN NKCR CSA File LR 44087 Class 3211-03 |
UL File E164353 CNN NKCR CSA File LR 44087 Class 3211-03 |
Conforming to Standards |
For receiver: EN 300 328 V2.1.1:
2016-11 EN 60950-1:2006 + A11: 2009 For transmitter: EN 300 440 V2.1.1: 2017-03 EN 62479: 2010 |
For receiver: EN 300 328 V2.1.1:
2016-11 For transmitter: EN
300 440 V2.1.1: 2017-03 |
CE Marked |
EN/IEC 60947-5-1, EN/IEC 60204-32, EN/IEC 60947-5-5, and EN/ISO 13850 (for versions with trigger action emergency stop) UL 508 CSA C22-2 No. 14 RoHS compliant |
EN/IEC 60947-5-1, EN/IEC 60204-32, EN/IEC 60947-5-5, and EN/ISO 13850 (for versions with trigger action emergency stop) UL 508 CSA C22-2 No. 14 RoHS compliant |
Degree of Protection |
Transmitter: IP65/NEMA 4, Receiver: IP66 |
IP67 for transmitter and IP66 for receiver |
NEMA 1, 3, 3R, 4, 4X |
NEMA 1, 4, 4X, 5 IP65 IK08 |
NEMA 1, 4, 4X, 5 IP65 IK08 |
Operating Temperature F° (C°) |
-4 to 131 (-20 to 55) |
-4…131 °F (-20…55 °C) |
-13 to 140 (-25 to 60) |
-13 to 140 (-25 to 60) |
-13 to 140 (-25 to 60) |
Storage Temperature F° (C°) |
-4 to 113 (-20 to 45) |
-4…113 °F (-20…45 °C) |
-40 to 158 (-40 to 70) |
-40 to 158 (-40 to 70) |
-40 to 158 (-40 to 70) |
Housing Material |
Polyurethane |
Polyurethane |
Polycarbonate / PET Polyester Blend |
Yellow Polypropylene |
Yellow Polypropylene |
Rated Operational Characteristics [1] |
— — |
— |
AC - B600 |
AC-15: A600 or Ue = 600V, le = 1.2A or Ue = 240V, le = 3A |
AC-15: A600 or Ue = 600V, le = 1.2A or Ue = 240V, le = 3A |
— |
DC - P600 |
DC-13: Q600 or Ue = 600V. le = 0.1A or Ue = 250V, le = 0.27A |
DC-13: Q600 or Ue = 600V. le = 0.1A or Ue = 250V, le = 0.27A |
||
Thermal Current |
— |
— |
Continuous 5A |
Continuous 10A |
Continuous 10A |
Connection Type |
— |
— |
1/2 in. NPT screw clamp terminals |
8–26 mm cable entry screw clamp terminals |
8–26 mm cable entry screw clamp terminals |
Cable Size |
Receiver: PVC torsion cable, largest
single wire Ø 0.21 |
Receiver: PVC torsion cable, largest single wire Ø 0.21 mm (0.008 in.), outer Ø 12.0 mm (0.47 in.) |
— |
1 x 0.5 mm² (20AWG) min. 2 x 1.5 mm² (16AWG) max. 1 x 2.5 mm² (14AWG) max. |
1 x 14 AWG (copper only) |
Digest Location |
XAR | XAR |