Pendant Stations

Refer to Catalogs DIA5ED2140103EN * and 9001CT1001 **

Pendant Station Selection Guide

Family

XAR
eXL Hoist

9001BW

XACA2

XACA0

9001SKYP

 


Type of Product

*Wireless Pendant

**2-Button Pendant

**2-Button Pistol Grip Pendant

**General Purpose Pendant

**Heavy Duty Pendant

Number of operators

6

2

2

2, 3, 4, 6, 8, 12

2, 4, 6, 8, 10

Approvals

UL File E164353,
CCN NKCR/NKR7 (cULus) CSA File LR44087
Class 3211-07

UL File E78403

CNN NKCR

CSA File LR25490

Class 3211-03

UL File E164353

CNN NKCR

CSA File LR 44087 Class 3211-03

UL File E164353 CNN NKCR

CSA File LR 44087 Class 3211-03

UL File E78403

CNN NKCR

CSA File LR25490

Class 3211-03

Conforming to Standards

EN/IEC 60947-5-1,
EN/IEC 60204-32,
UL 508,
CSA 22-2 No. 14 and
EN/ISO 13849-1,
EN/IEC 62061,
EN/IEC 61508,
EN/ISO 13850
EN 13557,
EN 15011
UL,
CSA,
CE,
CCC
RoHS Compliant

CE Marked

EN/IEC 60947-5-1,

EN/IEC 60204-32,

EN/IEC 60947-5-5, and

EN/ISO 13850 (for versions with trigger action emergency stop)

UL 508

CSA C22-2 No. 14

RoHS compliant

EN/IEC 60947-5-1,

EN/IEC 60204-32,

EN/IEC 60947-5-5, and

EN/ISO 13850 (for versions with trigger action emergency stop)

UL 508

CSA C22-2 No. 14

RoHS compliant

CE Marked

Degree of Protection

IP65, NEMA 4

NEMA 1, 3, 3R, 4, 4X

NEMA 1, 4, 4X, 5

IP65

IK08

NEMA 1, 4, 4X, 5

IP65

IK08

NEMA 1,2, 3, 4, 4X, 12, 13

Operating Temperature F° (C°)

-4 to 140 (-20 to 60)

-13 to 140 (-25 to 60)

-13 to 140 (-25 to 60)

-13 to 140 (-25 to 60)

-13 to 140 (-25 to 60)

Storage Temperature F° (C°)

-4 to 140 (-20 to 60)

-40 to 158 (-40 to 70)

-40 to 158 (-40 to 70)

-40 to 158 (-40 to 70)

-40 to 158 (-40 to 70)

Housing Material

Polycarbonate (PBT)

Polycarbonate / PET Polyester Blend

Yellow Polypropylene

Yellow Polypropylene

Yellow Polycarbonate

Rated Operational

Characteristics [1]
ZBRH●H
AC - C300
ZBRH●W
AC - B300
DC - R300

AC - B600

AC-15: A600

or Ue = 600V, le = 1.2A

or Ue = 240V, le = 3A

AC-15: A600

or Ue = 600V, le = 1.2A

or Ue = 240V, le = 3A

SKRU2-SKRU5

AC - B300

DC - P600

DC - P600

DC-13: Q600

or Ue = 600V. le = 0.1A

or Ue = 250V, le = 0.27A

DC-13: Q600

or Ue = 600V. le = 0.1A

or Ue = 250V, le = 0.27A

SKRU1, 10, 11

AC - A600

DC - P600

Thermal Current

ZBRH●H - 4A
ZBRH●W - 6A

Continuous 5A

Continuous 10A

Continuous 10A

Connection Type

1/2 in. NPT

screw clamp terminals

8–26 mm cable entry

screw clamp terminals

8–26 mm cable entry

screw clamp terminals

NPT threaded conduit entry

screw clamp terminals

Cable Size

None: Wireless

1 x 0.5 mm² (20AWG) min.

2 x 1.5 mm² (16AWG) max.

1 x 2.5 mm² (14AWG) max.

1 x 14 AWG (copper only)

Digest Location

XAR

Type BW

XAC

XAC

SKYP

Footnotes

  1. OSHA Section 1910.179, Overhead and Gantry Cranes, limits voltage at pendant push buttons to 150 Vac or 300 Vdc max.

Was this helpful?