Event List
Event Characteristics
The events are listed according to the history in which they are logged.
Each event is defined by the following characteristics:
-
Code: event code
-
Event: user message
-
Type: not customizable
-
Entry/Exit: occurrence/completion event.
-
Pulse: instantaneous event.
-
-
-
Yes: the event is latched and the user must reset the event status.
-
No: the event is unlatched.
NOTE: The latch mode of events marked (1) in the following tables can be customized with EcoStruxure Power Commission software. -
-
-
Enabled
-
Disabled
NOTE: The activity of events marked (1) in the following tables can be customized with EcoStruxure Power Commission software. -
-
-
High severity events.
-
Medium severity events.
-
Low severity events.
-
-
-
Yes: the service LED is lit in either orange or red, depending on the severity of the event. Maintenance action is required
-
No: the service LED is not lit. No maintenance action is required.
-
Trip Events
Code |
Event |
History |
Type |
Latched |
Activity |
Severity |
Service LED |
---|---|---|---|---|---|---|---|
0x6400 (25600) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x6401 (25601) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x6402 (25602) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
(25603) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x6404 (25604) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x6406 (25606) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x6407 (25607) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x641F (25631) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x641D (25629) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x641E (25630) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x6414 (25620) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x6410 (25616) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x642A (25642) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x6411 (25617) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x642B (25643) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x6415 (25621) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x6416 (25622) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x6421 (25633) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x6423 (25635) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x6424 (25636) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
|
0x6432 (25650) |
Trip |
Pulse |
Yes |
Enabled |
High |
No |
Protection Events
Code |
Event |
History |
Type |
Latch |
Activity |
Severity |
Service LED |
---|---|---|---|---|---|---|---|
0x631D (25373) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x6306 (25350) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x0F11 (3857) |
Protection |
Pulse |
No(1) |
Enabled |
Low |
No |
|
0x03F5 (1013) |
Protection |
Entry/Exit |
No |
Enabled(1) |
Medium |
No |
|
0x6200 (25088) |
Protection |
Entry/Exit |
No(1) |
Enabled |
Medium |
No |
|
0x6300 (25344) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x6201 (25089) |
Protection |
Entry/Exit |
No(1) |
Enabled |
Low |
No |
|
0x6301 (25345) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x6302 (25346) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x050C (1292) |
Protection |
Entry/Exit |
No(1) |
Enabled |
Medium |
No |
|
0x6203 (25091) |
Protection |
Entry/Exit |
No(1) |
Enabled |
Low |
No |
|
0x6303 (25347) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x050D (1293) |
Protection |
Entry/Exit |
No(1) |
Enabled(1) |
Medium |
No |
|
0x6204 (25092) |
Protection |
Entry/Exit |
No(1) |
Enabled |
Low |
No |
|
0x6304 (25348) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x6210 (25104) |
Protection |
Entry/Exit |
No(1) |
Enabled |
Low |
No |
|
0x6310 (25360) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x622A (25130) |
Protection |
Entry/Exit |
No(1) |
Enabled |
Low |
No |
|
0x632A (25386) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x6211 (25105) |
Protection |
Entry/Exit |
No(1) |
Enabled |
Low |
No |
|
0x6311 (25361) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x622B (25131) |
Protection |
Entry/Exit |
No(1) |
Enabled |
Low |
No |
|
0x632B (25387) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x6216 (25110) |
Protection |
Entry/Exit |
No |
Enabled (1) |
Low |
No |
|
0x6316 (25366) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x6215 (25109) |
Protection |
Entry/Exit |
No |
Enabled(1) |
Low |
No |
|
0x6315 (25365) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x6214 (25108) |
Protection |
Entry/Exit |
No(1) |
Enabled |
Medium |
No |
|
0x6314 (25364) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x6221 (25121) |
Protection |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x6321 (25377) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x6223 (25123) |
Protection |
Entry/Exit |
No(1) |
Enabled |
Low |
No |
|
0x6224 (25124) |
Protection |
Entry/Exit |
No(1) |
Enabled |
Low |
No |
|
0x6323 (25379) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x6324 (25380) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x6232 (25138) |
Protection |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x6332 (25394) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x0C03 (3075) |
Protection |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x0C04 (3076) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x0C05 (3077) |
Protection |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x0C06 (3078) |
Protection |
Pulse |
No |
Enabled |
Low |
No |
|
0x1300 (4864) |
Protection |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x1309 (4873) |
Protection |
Entry/Exit |
No(1) |
Enabled |
Low |
No |
|
0x130A (4874) |
Protection |
Entry/Exit |
No(1) |
Enabled |
Low |
No |
|
0x1100 (4352) |
Protection |
Pulse |
No(1) |
Enabled |
Low |
No |
|
0x1108 (4360) |
Protection |
Pulse |
No(1) |
Enabled |
Medium |
No |
|
0x0EF8 (3832) |
Protection |
Entry/Exit |
No |
Enabled |
Low |
No |
|
(1) Customizable with EcoStruxure Power Commission software |
Diagnostic Events
Code |
Event |
History |
Type |
Latch |
Activity |
Severity |
Service LED |
---|---|---|---|---|---|---|---|
0x1120 (4384) |
Diagnostic |
Pulse |
Yes |
Enabled(1) |
Medium |
No |
|
0x1121 (4385) |
Diagnostic |
Pulse |
Yes |
Enabled(1) |
Medium |
No |
|
0x1122 (4386) |
Diagnostic |
Pulse |
Yes |
Enabled(1) |
Medium |
No |
|
0x1123 (4387) |
Diagnostic |
Pulse |
Yes |
Enabled(1) |
Medium |
No |
|
0x1302 (4866) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x1303 (4867) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x1304 (4868) |
Diagnostic |
Pulse |
No |
Enabled |
Low |
No |
|
0x142C (5164) |
Diagnostic |
Pulse |
No |
Enabled |
Medium |
No |
|
0x142D (5165) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x1400 (5120) |
Diagnostic |
Entry/Exit |
No |
Enabled |
High |
Yes |
|
0x1404 (5124) |
Diagnostic |
Entry/Exit |
No |
Enabled |
High |
Yes |
|
0x1405 (5125) |
Diagnostic |
Entry/Exit |
No |
Enabled |
High |
Yes |
|
0x1406 (5126) |
Diagnostic |
Entry/Exit |
No |
Enabled |
High |
Yes |
|
0x1416 (5142) |
Diagnostic |
Entry/Exit |
No |
Enabled |
High |
Yes |
|
0x1402 (5122) |
Diagnostic |
Entry/Exit |
No |
Enabled |
High |
Yes |
|
0x1403 (5123) |
Diagnostic |
Entry/Exit |
No |
Enabled |
High |
Yes |
|
0x1408 (5128) |
Diagnostic |
Entry/Exit |
No |
Enabled |
High |
Yes |
|
0x1430 (5168) |
Diagnostic |
Entry/Exit |
No |
Enabled |
High |
Yes |
|
0x142F (5167) |
Last modification of protection settings has not been completely applied |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
No |
0x140F (5135) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
Yes |
|
0x1474 (5236) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
Yes |
|
0x1475 (5237) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
Yes |
|
0x1476 (5238) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
Yes |
|
0x1407 (5127) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x1470 (5232) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x1471 (5233) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
Yes |
|
0x1472 (5234) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
Yes |
|
0x1473 (5235) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x1411 (5137) |
|
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
No |
0x1478 (5240) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x1479 (5241) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
Yes |
|
0x147C (5244) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
Yes |
|
0x1412 (5138) |
Diagnostic |
Entry/Exit |
No |
Enabled(1) |
Low |
Yes |
|
0x1414 (5140) |
Diagnostic |
Entry/Exit |
No |
Enabled(1) |
Medium |
Yes |
|
0x1415 (5141) |
Diagnostic |
Entry/Exit |
No |
Enabled(1) |
Medium |
Yes |
|
0x140A (5130) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x147B (5243) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
Yes |
|
0x1422 (5154) |
Diagnostic |
Entry/Exit |
No |
Enabled(1) |
Medium |
Yes |
|
0x1433 (5171) |
Diagnostic |
Entry/Exit |
No |
Enabled(1) |
Medium |
Yes |
|
0x1437 (5175) |
Diagnostic |
Entry/Exit |
No |
Enabled(1) |
Low |
No |
|
0x1436 (5174) |
Diagnostic |
Pulse |
No |
Enabled |
Low |
No |
|
0x1434 (5172) |
Diagnostic |
Entry/Exit |
No |
Disabled |
Medium |
No |
|
0x1409 (5129) |
Diagnostic |
Entry/Exit |
No |
Enabled |
High |
Yes |
|
0x0D0A (3338) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x0D0E (3342) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
Yes |
|
0x0D00 (3328) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x0D01 (3329) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x0D02 (3330) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x0D03 (3331) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x0D08 (3336) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x0D09 (3337) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
Yes |
|
0x1413 (5139) |
IΔn/Ig test - no trip |
Diagnostic |
Pulse |
No |
Enabled |
High |
No |
0x142A (5162) |
IΔn/Ig test button pressed |
Diagnostic |
Pulse |
No |
Enabled |
Low |
No |
0x1305 (4869) |
Diagnostic |
Pulse |
No |
Enabled |
Low |
No |
|
0x1440 (5184) |
Diagnostic |
Entry/Exit |
No |
Enabled(1) |
Medium |
Yes |
|
0x1441 (5185) |
Diagnostic |
Entry/Exit |
No |
Enabled(1) |
Medium |
Yes |
|
0x1442 (5186) |
Diagnostic |
Entry/Exit |
No |
Enabled |
High |
Yes |
|
0x1443 (5187) |
Remaining service life of circuit breaker is below alarm threshold |
Diagnostic |
Entry/Exit |
No |
Enabled(1) |
Medium |
Yes |
0x1444 (5188) |
Diagnostic |
Entry/Exit |
No |
Enabled(1) |
High |
Yes |
|
0x1460 (5216) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
Yes |
|
0x1461 (5217) |
Diagnostic |
Entry/Exit |
No |
Disabled(1) |
Medium |
Yes |
|
0x1450 (5200) |
Diagnostic |
Entry/Exit |
No |
Enabled(1) |
Medium |
Yes |
|
0x1451 (5201) |
Diagnostic |
Entry/Exit |
No |
Enabled(1) |
High |
Yes |
|
0x1462 (5218) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
Yes |
|
0x1463 (5219) |
Diagnostic |
Entry/Exit |
No |
Disabled(1) |
Medium |
Yes |
|
0x1464 (5220) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
Yes |
|
0x1465 (5221) |
Diagnostic |
Entry/Exit |
No |
Disabled(1) |
Medium |
Yes |
|
0x1466 (5222) |
Diagnostic |
Entry/Exit |
No |
Disabled(1) |
Medium |
Yes |
|
0x1467 (5223) |
Diagnostic |
Entry/Exit |
No |
Disabled(1) |
Medium |
Yes |
|
0x1468 (5224) |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
Yes |
|
0x1469 (5225) |
Diagnostic |
Entry/Exit |
No |
Disabled(1) |
Medium |
Yes |
|
0x1306 (4870) |
Diagnostic |
Entry/Exit |
No |
Enabled(1) |
Low |
No |
|
0x150F (5391) |
Diagnostic |
Entry/Exit |
No |
Enabled |
High |
No |
|
0x1510 (5392) |
Internal Current Power Supply (CPS) sensors malfunction. Tsd forced to 0 |
Diagnostic |
Entry/Exit |
No |
Enabled |
High |
No |
0x1511 (5393) |
Partial Internal Current Power Supply (CPS) sensors malfunction |
Diagnostic |
Entry/Exit |
No |
Enabled |
Medium |
No |
0x1512 (5394) |
Partial Internal Current Power Supply (CPS) sensors major malfunction |
Diagnostic |
Entry/Exit |
No |
Enabled |
High |
No |
0x1438 (5176) |
Diagnostic |
Entry/Exit |
No |
Enabled(1) |
Medium |
No |
|
0x1445 (5189) |
Remaining service life of MicroLogic is below alarm threshold |
Diagnostic |
Entry/Exit |
No |
Enabled (1) |
Medium |
Yes |
0x1446 (5190) |
Diagnostic |
Entry/Exit |
No |
Enabled (1) |
High |
Yes |
|
0x1452 (5202) |
MX1 voltage release operation counter is above alarm threshold |
Diagnostic |
Entry/Exit |
No |
Enabled (1) |
Medium |
Yes |
0x1453 (5203) |
MX1 voltage release has reached the max number of operations |
Diagnostic |
Entry/Exit |
No |
Enabled (1) |
High |
Yes |
0x1454 (5204) |
XF voltage release operation counter is above alarm threshold |
Diagnostic |
Entry/Exit |
No |
Enabled (1) |
Medium |
Yes |
0x1455 (5205) |
Diagnostic |
Entry/Exit |
No |
Enabled (1) |
High |
Yes |
|
0x1456 (5206) |
MN undervoltage release operation counter is above alarm threshold |
Diagnostic |
Entry/Exit |
No |
Enabled(1) |
Medium |
Yes |
0x1457 (5207) |
MN undervoltage release has reached the max number of operations |
Diagnostic |
Entry/Exit |
No |
Enabled(1) |
High |
Yes |
0x1458 (5208) |
MX2 voltage release operation counter is above alarm threshold |
Diagnostic |
Entry/Exit |
No |
Enabled (1) |
Medium |
Yes |
0x1459 (5209) |
MX2 voltage release has reached the max number of operations |
Diagnostic |
Entry/Exit |
No |
Enabled (1) |
High |
Yes |
0x1480 (5248) |
Diagnostic |
Entry/Exit |
No |
Disabled(1) |
Medium |
Yes |
|
0x1481 (5249) |
Diagnostic |
Entry/Exit |
No |
Enabled (1) |
Medium |
Yes |
|
0x1482 (5250) |
Diagnostic |
Entry/Exit |
No |
Enabled(1) |
Medium |
Yes |
|
(1) Customizable with EcoStruxure Power Commission software |
Metering Events
Code |
Event |
History |
Type |
Latch |
Activity |
Severity |
Service LED |
---|---|---|---|---|---|---|---|
0x0F12 (3858) |
Metering |
Pulse |
No(1) |
Enabled |
Low |
No |
|
0x0F13 (3859) |
Metering |
Pulse |
No(1) |
Enabled |
Low |
No |
|
0x0F14 (3860) |
Metering |
Pulse |
No(1) |
Enabled |
Low |
No |
|
0x0F15 (3861) |
Metering |
Pulse |
No(1) |
Enabled |
Low |
No |
|
0x0F16 (3862) |
Metering |
Pulse |
No(1) |
Enabled |
Low |
No |
|
0x0F17 (3863) |
Metering |
Pulse |
No(1) |
Enabled |
Low |
No |
|
0x0F19 (3865) |
Metering |
Pulse |
No(1) |
Enabled |
Low |
No |
|
0x0F1A (3866) |
Metering |
Pulse |
No(1) |
Enabled |
Low |
No |
|
0x0F18 (3864) |
Metering |
Pulse |
No(1) |
Enabled |
Low |
No |
|
(1) Customizable with EcoStruxure Power Commission software |
Operation Events
Code |
Event |
History |
Type |
Latch |
Activity |
Severity |
Service LED |
---|---|---|---|---|---|---|---|
0x0C02 (3074) |
Operation |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x1000 (4096) |
Operation |
Pulse |
No(1) |
Enabled(1) |
Low |
No |
|
0x1001 (4097) |
Operation |
Pulse |
No(1) |
Enabled(1) |
Low |
No |
|
0x0411 (1041) |
Operation |
Pulse |
No |
Enabled(1) |
Low |
No |
|
0x0410 (1040) |
Operation |
Pulse |
No |
Enabled(1) |
Low |
No |
|
0x1002 (4098) |
Operation |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x1004 (4100) |
Operation |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x111F (4383) |
Operation |
Pulse |
No |
Enabled |
Low |
No |
|
0x100A (4106) |
Operation |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x1009 (4105) |
Operation |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x1307 (4871) |
Operation |
Pulse |
No |
Enabled |
Low |
No |
|
0x130B (4875) |
Operation |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x130C (4876) |
Operation |
Entry/Exit |
No |
Enabled |
Low |
No |
|
(1) Customizable with EcoStruxure Power Commission software |
Configuration Events
Code |
Event |
History |
Type |
Latch |
Activity |
Severity |
Service LED |
---|---|---|---|---|---|---|---|
0x0D06 (3334) |
Config error IO/CU:dual settings or inhibit cls. |
Configuration |
Entry/Exit |
No |
Enabled |
Medium |
No |
0x0D0C (3340) |
Configuration |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x0D0D (3341) |
Configuration |
Entry/Exit |
No |
Enabled |
Medium |
No |
|
0x112B (4395) |
Configuration |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x112C (4396) |
Configuration |
Pulse |
No |
Enabled |
Medium |
No |
|
0x1107 (4359) |
Configuration |
Pulse |
No(1) |
Enabled |
Low |
No |
|
0x1130 (4400) |
Configuration |
Pulse |
No |
Enabled |
Low |
No |
|
0x1131 (4401) |
Configuration |
Pulse |
No |
Enabled |
Low |
No |
|
(1) Customizable with EcoStruxure Power Commission software |
Communication Events
Code |
Event |
History |
Type |
Latch |
Activity |
Severity |
Service LED |
---|---|---|---|---|---|---|---|
0x1301 (4865) |
Communication |
Entry/Exit |
No |
Enabled |
Low |
No |
|
0x1429 (5161) |
Communication |
Entry/Exit |
No |
Enabled(1) |
Low |
No |
|
0x1427 (5159) |
Communication |
Entry/Exit |
No |
Enabled |
Low |
No |
|
(1) Customizable with EcoStruxure Power Commission software |
For information: Text in column ‘Event’ (i.e. the user message) = “Text labels” from Event census