About the Document
Document Scope
This guide provides complete information necessary to use the TeSys Tera system which includes:
-
LTMT main unit
-
LTMTCT/LTMTCTV sensor modules
- LTMT expansion modules
-
LTMTCUF control operator unit
The purpose of this guide is to:
-
Provide information necessary to configure and operate the TeSys Tera system and its components
-
Describe the metering, monitoring, protection, and control functions of the TeSys Tera system
This guide is intended for:
-
Design engineers
-
System integrators
-
System operators
Validity Note
This document is valid for the following certified components of the TeSys Tera system:
-
LTMTMFM: LTMT main unit with Modbus RTU protocol, 100–240 Vac/Vdc
-
LTMTMBD: LTMT main unit with Modbus RTU protocol, 24 Vdc
-
LTMTPFM: LTMT main unit with PROFIBUS DP protocol, 100–240 Vac/Vdc
-
LTMTPBD: LTMT main unit with PROFIBUS DP protocol, 24 Vdc
-
LTMTCT3T: LTMT Horizontal Sensor Module with current transformer, current range = 0.3–3 A
-
LTMTCT25T: LTMT Horizontal Sensor Module with current transformer, current range = 2.5–25 A
-
LTMTCT100T: LTMT Horizontal Sensor Module with current transformer, current range = 10–100 A
-
LTMTCTV3T: LTMT Horizontal Sensor Module with current and voltage transformers, current range = 0.3–3 A, voltage range = 60–690 Vac
-
LTMTCTV25T: LTMT Horizontal Sensor Module with current and voltage transformers, current range = 2.5–25 A, voltage range = 60–690 Vac
-
LTMTCTV100T: LTMT Horizontal Sensor Module with current and voltage transformers, current range = 10–100 A, voltage range = 60–690 Vac
-
LTMTCTV3UT: LTMT Horizontal Sensor Module with current and voltage transformers, current range = 0.3–3 A, voltage range = 60–600 Vac
-
LTMTCTV25UT: LTMT Horizontal Sensor Module with current and voltage transformers, current range = 2.5–25 A, voltage range = 60–600 Vac
-
LTMTCTV100UT: LTMT Horizontal Sensor Module with current and voltage transformers, current range = 10–100 A, voltage range = 60–600 Vac
-
LTMTIN42FM: LTMT expansion unit with four digital inputs and two digital outputs, 100–240 Vac/Vdc
-
LTMTIN42BD: LTMT expansion unit with four digital inputs and two digital outputs, 24 Vdc
-
LTMT9RJ1015: LTMT main unit to LTMTCT/LTMTCTV sensor module RJ11 connector cable 0.15 m (5.9 in) in length
-
LTMT9RJ401: LTMT main unit to LTMT expansion unit RJ45 connector cable 0.1 m (3.9 in) in length
-
LTMT9RJ105:LTMT main unit to LTMTCT/LTMTCTV sensor module RJ11 connector cable 0.5 m (19.6 in) in length
-
LTMTCUF: Control Operator Unit
-
LTMT9RJ102: LTMT main unit to LTMTCT/LTMTCTV sensor module RJ11 connector cable 0.2 m (7.87 in) in length
-
LTMT9EX10: LTMT main unit to LTMT expansion module RJ45 connector cable 1 m (39.37 in) in length
-
LTMT9CU10S: LTMT main unit to LTMTCUF control operator unit cable 1 m (39.37 in) in length
-
LTMT9CU30S: LTMT main unit to LTMTCUF control operator unit cable 3 m (118.11 in) in length
The certification of other components of the TeSys Tera system mentioned in this document is in progress.
The availability of some functions described in this document depends on the communication protocol used and the physical modules installed on the TeSys Tera system.
General Cybersecurity Information
In recent years, the growing number of networked machines and production plants has seen a corresponding increase in the potential for cyber threats, such as unauthorized access, data breaches, and operational disruptions. You must, therefore, consider all possible cybersecurity measures to help protect assets and systems against such threats.
To help keep your Schneider Electric products secure and protected, it is in your best interest to implement the cybersecurity best practices as described in the Cybersecurity Best Practices document.
Schneider Electric provides additional information and assistance:
-
Subscribe to the Schneider Electric security newsletter.
-
Visit the Cybersecurity Support Portal web page to:
-
Find Security Notifications.
-
Report vulnerabilities and incidents.
-
-
Visit the Schneider Electric Cybersecurity and Data Protection Posture web page to:
-
Access the cybersecurity posture.
-
Learn more about cybersecurity in the cybersecurity academy.
-
Explore the cybersecurity services from Schneider Electric.
-
Environmental Data
For product compliance and environmental information, refer to the Schneider Electric Environmental Data Program.
Available Languages of the Document
The document is available in these languages:
-
English
Related Documents
Title of documentation |
Description |
Reference number |
---|---|---|
TeSys Tera Motor Management System Catalog |
The catalog
|
|
TeSys Tera Motor Management System Installation Guide |
This guide describes the installation, commissioning, and maintenance of the LTMT main unit, LTMTCT/LTMTCTV sensor modules, LTMT expansion unit, and LTMTCUF control operator unit. |
|
TeSys Tera Motor Management System Modbus RTU Communication Guide |
This guide describes the Modbus RTU network protocol communication of the LTMT main unit. |
|
TeSys Tera Motor Management System PROFIBUS DP Guide |
This guide describes the PROFIBUS DP network protocol communication of the LTMT main unit. |
|
TeSys Tera Motor Management System LTMTCUF User Guide |
This guide describes how to install, configure, and use the LTMTCUF control operator unit. |
|
TeSys Tera Motor Management System DTM Library Online Help Guide |
This guide describes the TeSys Tera DTM library which allows the customization of the control functions of the TeSys Tera Motor Management System. |
|
TeSys Tera Motor Management System DTM Library Release Note |
This document provides important information about the TeSys Tera DTM |
|
TeSys Tera Motor Management System Firmware Release Note |
This guide provides important information about the TeSys Tera system firmware packages and provides summary of new features and enhancement. |
To find documents online, visit the Schneider Electric download center (www.se.com/ww/en/download/).
Information on Non-Inclusive or Insensitive Terminology
As a responsible, inclusive company, Schneider Electric is constantly updating its communications and products that contain non-inclusive or insensitive terminology. However, despite these efforts, our content may still contain terms that are deemed inappropriate by some customers.
Trademarks
QR Code is a registered trademark of DENSO WAVE INCORPORATED in Japan and other countries.