Fiber Feature Classes

The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.

Fiber Manager 10.x

Feature Class

Equivalent Fiber Manager XI

Feature Class

Notes

DevicePoint

Communications Junction > Asset Group of Device Point

 

FiberFault

 

The FiberFault is a non-networked, point feature class used as a temporary marker of a fault location. It is included in the Fiber Manager 10.x sample data, but it is not required nor an actual fiber asset (it does not interact with Fiber Manager tools). You can add such a feature class in the Fiber Manager XI data model, if desired.

FiberOpticCable

Communications Line > Asset Group of Fiber Cable

 

FiberSlackloop

Communications Junction > Asset Group of Slackloop

 

FiberStructure

 

The FiberStructure is a non-networked, point feature class used to sketch fiber structures in the asset map. It is included in the Fiber Manager 10.x sample data, but it is not required nor an actual fiber asset (it does not interact with Fiber Manager tools).

You can add such a feature class in the Fiber Manager XI data model, if desired. However, if your company intends to implement Conduit Manager XI alongside Fiber Manager XI, then you should use the Conduit Manager XI feature classes and not create an additional FiberStructure feature class.

PatchLocation

Communications Junction > Asset Group of Patch Location

 

SplicePoint

Communications Junction > Asset Group of Splice

 

SplitterLocation

Communications Junction > Asset Group of Splitter

 

TransitionPoint

Communications Junction > Asset Group of Transition

 


Device Point

Fiber Manager 10.x Field

Equivalent Fiber Manager XI Field

Type

fiberchildclassmodelname 

fiberchildclassmodelname 

String

fiberparent 

fiberparent 

GUID

fiberparentclassmodelname 

fiberparentclassmodelname 

String

globalid

globalid

Global ID

locationdescription 

locationdescription 

String

symbolrotation 

symbolrotation 

Short Integer

thisfiberclassmodelname 

thisfiberclassmodelname 

String


Fiber Optic Cable

Fiber Manager 10.x Field

Equivalent Fiber Manager XI Field

Type

cablelength

cablelength

Double

cablelengthsource

cablelengthsource

String

cablemarkingunitofmeasure

There is no equivalent field in Fiber Manager XI. In Fiber Manager 10.x, this field would allow different units of measure to be assigned to different cables. With Fiber Manager XI, all calculations use the measurement units as set in the ArcGIS Pro map. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any calculation functionality in Fiber Manager XI.

cablename

cablename

String

cableowner

cableowner

String

cabletwistfactor

cabletwistfactor

Double

cabletype

cabletype

String

endingcablelengthmarking

endingcablelengthmarking

Integer

estsmattenuation1310

estsmattenuation1310

Double

estsmattenuation1550

estsmattenuation1550

Double

fibercount

fibercount

String (this was a Long Integer in Fiber Manager 10.x)

fiberchildclassmodelname 

fiberchildclassmodelname 

String

fiberparent 

fiberparent 

GUID

fiberparentclassmodelname 

fiberparentclassmodelname 

String

fieldnoteslength

fieldnoteslength

Double

glasslength

glasslength

Double

globalid

globalid

Global ID

installedby

installedby

String

multimodeavailabilityqty 

multimodeavailabilityqty 

Integer

overheadunderground 

Asset Type

Integer

segmentglasslength

segmentglasslength

Double

segmentlength

segmentlength

Double

singlemodeavailabilityqty

singlemodeavailabilityqty

Integer

startingcablelengthmarking

startingcablelengthmarking

Integer

thisfiberclassmodelname 

thisfiberclassmodelname 

String


Patch Location

Fiber Manager 10.x Field

Equivalent Fiber Manager XI Field

Type

fiberchildclassmodelname 

fiberchildclassmodelname 

String

fiberparent 

fiberparent 

GUID

fiberparentclassmodelname 

fiberparentclassmodelname 

String

globalid

globalid

Global ID

name 

 name

String

symbolrotation 

symbolrotation 

Short Integer

thisfiberclassmodelname 

thisfiberclassmodelname 

String


Slackloop

Fiber Manager 10.x Field

Equivalent Fiber Manager XI Field

Type

globalid

globalid

Global ID

length 

length 

Double

symbolrotation 

symbolrotation 

Short Integer


Splice Point

Fiber Manager 10.x Field

Equivalent Fiber Manager XI Field

Type

fiberchildclassmodelname 

fiberchildclassmodelname 

String

fiberparent 

fiberparent 

GUID

fiberparentclassmodelname 

fiberparentclassmodelname 

String

globalid

globalid

Global ID

locationdescription 

locationdescription 

String

symbolrotation 

symbolrotation 

Short Integer

thisfiberclassmodelname 

thisfiberclassmodelname 

String


Splitter

Fiber Manager 10.x Field

Equivalent Fiber Manager XI Field

Type

fiberchildclassmodelname 

fiberchildclassmodelname 

String

fiberparent 

fiberparent 

GUID

fiberparentclassmodelname 

fiberparentclassmodelname 

String

globalid

globalid

Global ID

locationdescription 

locationdescription 

String

symbolrotation 

symbolrotation 

Short Integer

thisfiberclassmodelname 

thisfiberclassmodelname 

String


Transition Point

Fiber Manager 10.x Field

Equivalent Fiber Manager XI Field

Type

fiberchildclassmodelname 

fiberchildclassmodelname 

String

fiberparent 

fiberparent 

GUID

fiberparentclassmodelname 

fiberparentclassmodelname 

String

globalid

globalid

Global ID

riserfootage 

length

Double

symbolrotation 

symbolrotation 

Short Integer

thisfiberclassmodelname 

thisfiberclassmodelname 

String

Device Point

The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.

Fiber Manager 10.x Field

Equivalent Fiber Manager XI Field

Type

fiberchildclassmodelname 

fiberchildclassmodelname 

String

fiberparent 

fiberparent 

GUID

fiberparentclassmodelname 

fiberparentclassmodelname 

String

globalid

globalid

Global ID

locationdescription 

locationdescription 

String

symbolrotation 

symbolrotation 

Short Integer

thisfiberclassmodelname 

thisfiberclassmodelname 

String

Fiber Optic Cable

The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.

Fiber Manager 10.x Field

Equivalent Fiber Manager XI Field

Type

cablelength

cablelength

Double

cablelengthsource

cablelengthsource

String

cablemarkingunitofmeasure

There is no equivalent field in Fiber Manager XI. In Fiber Manager 10.x, this field would allow different units of measure to be assigned to different cables. With Fiber Manager XI, all calculations use the measurement units as set in the ArcGIS Pro map. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any calculation functionality in Fiber Manager XI.

cablename

cablename

String

cableowner

cableowner

String

cabletwistfactor

cabletwistfactor

Double

cabletype

cabletype

String

endingcablelengthmarking

endingcablelengthmarking

Integer

estsmattenuation1310

estsmattenuation1310

Double

estsmattenuation1550

estsmattenuation1550

Double

fibercount

fibercount

String (this was a Long Integer in Fiber Manager 10.x)

fiberchildclassmodelname 

fiberchildclassmodelname 

String

fiberparent 

fiberparent 

GUID

fiberparentclassmodelname 

fiberparentclassmodelname 

String

fieldnoteslength

fieldnoteslength

Double

glasslength

glasslength

Double

globalid

globalid

Global ID

installedby

installedby

String

multimodeavailabilityqty 

multimodeavailabilityqty 

Integer

overheadunderground 

Asset Type

Integer

segmentglasslength

segmentglasslength

Double

segmentlength

segmentlength

Double

singlemodeavailabilityqty

singlemodeavailabilityqty

Integer

startingcablelengthmarking

startingcablelengthmarking

Integer

thisfiberclassmodelname 

thisfiberclassmodelname 

String

Patch Location

The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.

Fiber Manager 10.x Field

Equivalent Fiber Manager XI Field

Type

fiberchildclassmodelname 

fiberchildclassmodelname 

String

fiberparent 

fiberparent 

GUID

fiberparentclassmodelname 

fiberparentclassmodelname 

String

globalid

globalid

Global ID

name 

 name

String

symbolrotation 

symbolrotation 

Short Integer

thisfiberclassmodelname 

thisfiberclassmodelname 

String

Slackloop

The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.

Fiber Manager 10.x Field

Equivalent Fiber Manager XI Field

Type

globalid

globalid

Global ID

length 

length 

Double

symbolrotation 

symbolrotation 

Short Integer

Splitter

The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.

Fiber Manager 10.x Field

Equivalent Fiber Manager XI Field

Type

fiberchildclassmodelname 

fiberchildclassmodelname 

String

fiberparent 

fiberparent 

GUID

fiberparentclassmodelname 

fiberparentclassmodelname 

String

globalid

globalid

Global ID

locationdescription 

locationdescription 

String

symbolrotation 

symbolrotation 

Short Integer

thisfiberclassmodelname 

thisfiberclassmodelname 

String

Transition Point

The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.

Fiber Manager 10.x Field

Equivalent Fiber Manager XI Field

Type

fiberchildclassmodelname 

fiberchildclassmodelname 

String

fiberparent 

fiberparent 

GUID

fiberparentclassmodelname 

fiberparentclassmodelname 

String

globalid

globalid

Global ID

riserfootage 

length

Double

symbolrotation 

symbolrotation 

Short Integer

thisfiberclassmodelname 

thisfiberclassmodelname 

String

QR Code is a registered trademark of DENSO WAVE INCORPORATED in Japan and other countries.