Fiber Object Tables
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Object Table |
Equivalent Fiber Manager XI Object Class |
Notes |
---|---|---|
F_ACTIVEDEVICE |
ActiveDevice |
|
F_ACTIVERECEIVEPORT |
ActiveCommonPort |
|
F_ACTIVETRANSMITPORT |
ActiveSplitPort |
|
F_BACKSIDEPORT |
BackPort |
|
F_BUFFERTUBE |
BufferTube |
|
F_CHASSIS |
Support is coming in a future release of Fiber Manager XI |
|
F_CIRCUIT |
Circuit |
|
F_CIRCUITCOMPONENT |
CircuitComponent |
|
F_DEVICE |
Dev |
|
F_DEVICEPORT |
DevPort |
|
F_FIBER |
Strand and Ribbon Strand |
In Fiber Manager 10.x, all fibers were included in the F_FIBER table. In Fiber Manager XI, they are divided between two tables (Strand and Ribbon Strand) depending on whether they are in a buffertube or ribbon bundle, respectively. |
F_FIBERCONNECTIONOBJECT |
Connection |
|
F_FRONTSIDEPORT |
FrontPort |
|
F_INTERLEAVEINPORT |
Support is coming in a future release of Fiber Manager XI |
|
F_INTERLEAVEINTERNALINPORT |
Support is coming in a future release of Fiber Manager XI |
|
F_INTERLEAVEINTERNALOUTPORT |
Support is coming in a future release of Fiber Manager XI |
|
F_INTERLEAVEOUTPORT |
Support is coming in a future release of Fiber Manager XI |
|
F_INTERLEAVESPLITTER |
Support is coming in a future release of Fiber Manager XI |
|
F_INTERLEAVETHROUGHPORTIN |
Support is coming in a future release of Fiber Manager XI |
|
F_INTERLEAVETHROUGHPORTOUT |
Support is coming in a future release of Fiber Manager XI |
|
F_PASSIVECOMMONPORT |
PassiveDeviceCommonPort |
|
F_PASSIVEDEVICE |
PassiveDevice |
|
F_PASSIVESPLITPORT |
PassiveSplitPort |
|
F_PATCHPANEL |
PP |
|
F_PATCHPANELCARD |
PPCard |
|
F_RACK |
Rack |
|
F_RIBBON |
Bundle and Ribbon |
In Fiber Manager 10.x, the single F_RIBBON table included attributes for both bundles and ribbons. In Fiber Manager XI, Bundles and Ribbons are in separate tables. |
F_SFP |
Fiber Manager XI does not plan on including small form-factor pluggable devices in its data model. However, you can model them as an Active Device. |
|
F_SFPCOMMONPORT |
Fiber Manager XI does not plan on including small form-factor pluggable devices in its data model. However, you can model them as an Active Device. |
|
F_SFPSPLITPORT |
Fiber Manager XI does not plan on including small form-factor pluggable devices in its data model. However, you can model them as an Active Device. |
|
F_SHELF |
Shelf |
|
F_SPLITTERINPUTPORT |
SplitIn |
This is the child of the Communications Junction > Asset Group of Splitter. This splitter is sketched on the map, and the SplitIn is related to it to model the input ports of the splitter. SplitIn is not used to represent splitter ports associated with a splitter that’s housed in a patch location or splice. |
F_SPLITTEROUTPUTPORT |
SplitOut |
This is the child of the Communications Junction > Asset Group of Splitter. This splitter is sketched on the map, and the Splitout is related to it to model the output ports of the splitter. SplitOut is not used to represent splitter ports associated with a splitter that’s housed in a patch location or splice. |
F_SPLITTERDEVICE |
PassiveDevice or ActiveDevice |
This splitter device is meant to represent a splitter that is housed in a patch location or splice. It is not meant to be related to the Communications Junction > Asset Group of Splitter that is sketched on the map. Fiber Manager XI does not provide a direct equivalent of the F_SPLITTERDEVICE object table. Instead, you can model your splitters that reside in patch locations or splices as either PassiveDevices or ActiveDevices. Most companies differentiate “passive” and “active” by whether or not the device is non-powered or powered, respectively. |
F_SPLITTERDEVICEINPUTPORT |
PassiveDeviceCommonPort or ActiveDeviceCommonPort |
Read the note above regarding F_SPLITTERDEVICE. With that knowledge, this represents the input ports associated with a splitter that’s housed in a patch location or splice. |
F_SPLITTERDEVICEOUTPUTPORT |
PassiveSplitPort or ActiveSplitPort |
Read the note above regarding F_SPLITTERDEVICE. With that knowledge, this represents the output ports associated with a splitter that’s housed in a patch location or splice. |
Active Device
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
activedeviceheight |
deviceheight |
Short Integer |
activedevicename |
devicename |
String |
activedeviceposition |
deviceposition |
Short Integer |
activedevicewidth |
devicewidth |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
numberofportcolumns |
numberofportcolumns |
Short Integer |
numberofportrows |
numberofportrows |
Short Integer |
sides |
sides |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Active Common Port
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
height |
height |
Short Integer |
lambdamax |
lambdamax |
Double |
lambdamin |
lambdamin |
Double |
portname |
portname |
String |
portnumber |
portnumber |
Short Integer |
portpositionondevice |
portpositionondevice |
Short Integer |
sides |
sides |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
width |
width |
Short Integer |
Active Split Port
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
height |
height |
Short Integer |
impliedalignment |
impliedalignment |
Short Integer |
impliedconnectionsourceguid |
impliedconnectionsourceguid |
GUID |
lambdamax |
lambdamax |
Double |
lambdamin |
lambdamin |
Double |
portname |
portname |
String |
portnumber |
portnumber |
Short Integer |
portpositionondevice |
portpositionondevice |
Short Integer |
porttype |
porttype |
String |
sides |
sides |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
width |
width |
Short Integer |
Back Port
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
defaultheight |
defaultheight |
Short Integer |
defaultwidth |
defaultwidth |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
impliedconnectionsourceguid |
impliedconnectionsourceguid |
GUID |
portname |
portname |
String |
portnumber |
portnumber |
Short Integer |
portpositiononcard |
portpositiononcard |
Short Integer |
porttype |
porttype |
String |
racksides |
sidesofrackshownon |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Buffer Tube
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
buffertubecolor |
buffertubecolor |
String |
buffertubename |
buffertubename |
String |
buffertubenumber |
buffertubenumber |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Bundle
-
In Fiber Manager 10.x, the F_RIBBON table included all information for both bundles and ribbons. Thus, during migration, you need to migrate data specific to the ribbons out of the F_RIBBON table and into the Ribbon table in Fiber Manager XI, and you need to migrate data specific to the bundles out of the F_RIBBON table and into the Bundle table in Fiber Manager XI.
-
Because these were previously stored in a single table in Fiber Manager 10.x, for Fiber Manager XI you also need to create the parent/child relationships with appropriate fiberparent GUIDs between the Bundle and Ribbon tables. In other words, because in Fiber Manager 10.x it was a single table of F_RIBBON (no relationship) but in Fiber Manager XI it is now two related tables of Bundle > Ribbon, a new relationship has been inserted. This new relationship does not have any pre-existing GUIDs to track who is related to whom, and these GUIDs need to be created.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
bundlecolor |
bundlecolor |
String |
bundlename |
bundlename |
String |
bundlenumber |
bundlenumber |
Integer |
bundleposition |
bundleposition |
Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Circuit
Circuit Component
There is no equivalent object table in Fiber Manager XI. If you want to preserve this table, you can, but it does not bear any functionality in Fiber Manager XI.
Connection
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
aclassmodelname |
aclassmodelname |
String |
aconnectionobjectglobalid |
aconnectionobjectglobalid |
GUID |
attentuation1310 |
attentuation1310 |
Double |
attentuation1550 |
attentuation1550 |
Double |
bclassmodelname |
bclassmodelname |
String |
bconnectionobjectglobalid |
bconnectionobjectglobalid |
GUID |
containerclassmodelname |
containerclassmodelname |
String |
containerglobalid |
containerglobalid |
GUID |
globalid |
globalid |
Global ID |
splicetype |
splicetype |
String |
traynumber |
traynumber |
Short Integer |
Dev
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
deviceheight |
defaultdeviceheight |
Short Integer |
devicewidth |
defaultdevicewidth |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
name |
name |
String |
numberofportcolumns |
numberofportcolumns |
Short Integer |
numberofportrows |
numberofportrows |
Short Integer |
rackposition |
positiononrack |
Short Integer |
racksides |
sidesofrackshownon |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Dev Port
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
height |
defaultheight |
Short Integer |
lambdamax |
lambdamax |
Double |
lambdamin |
lambdamin |
Double |
portname |
There is no equivalent field in Fiber Manager XI. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any functionality in Fiber Manager XI. |
|
portnumber |
portnumber |
Long Integer |
portstatus |
portstatus |
Short Integer |
porttype |
porttype |
String |
racksides |
sideofrackshownon |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
width |
defaultwidth |
Short Integer |
Connection
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
aclassmodelname |
aclassmodelname |
String |
aconnectionobjectglobalid |
aconnectionobjectglobalid |
GUID |
attentuation1310 |
attentuation1310 |
Double |
attentuation1550 |
attentuation1550 |
Double |
bclassmodelname |
bclassmodelname |
String |
bconnectionobjectglobalid |
bconnectionobjectglobalid |
GUID |
containerclassmodelname |
containerclassmodelname |
String |
containerglobalid |
containerglobalid |
GUID |
globalid |
globalid |
Global ID |
splicetype |
splicetype |
String |
traynumber |
traynumber |
Short Integer |
Front Port
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
defaultheight |
defaultheight |
Short Integer |
defaultwidth |
defaultwidth |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
portname |
portname |
String |
portnumber |
portnumber |
Long Integer |
portpositiononcard |
portpositiononcard |
Short Integer |
porttype |
porttype |
String |
racksides |
sidesofrackshownon |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Passive Device Common Port
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
height |
height |
Short Integer |
lambdamax |
lambdamax |
Double |
lambdamin |
lambdamin |
Double |
portname |
portname |
String |
portnumber |
portnumber |
Short Integer |
portpositionondevice |
portpositionondevice |
Short Integer |
portstatus |
portstatus |
Short Integer |
porttype |
porttype |
String |
sides |
sides |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
width |
width |
Short Integer |
Passive Device
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
deviceheight |
deviceheight |
Short Integer |
devicename |
devicename |
String |
deviceposition |
deviceposition |
Long Integer |
devicewidth |
devicewidth |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
sides |
sides |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Passive Device Split Port
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
height |
height |
Short Integer |
impliedalignment |
impliedalignment |
Short Integer |
impliedconnectionsourceguid |
impliedconnectionsourceguid |
GUID |
lambdamax |
lambdamax |
Double |
lambdamin |
lambdamin |
Double |
portname |
portname |
String |
portnumber |
portnumber |
Short Integer |
portpositionondevice |
portpositionondevice |
Short Integer |
porttype |
porttype |
String |
sides |
sides |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
width |
width |
Short Integer |
Patch Panel (PP)
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
defaultcardwidth |
defaultcardwidth |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
name |
name |
String |
numberofcardcolumns |
numberofcardcolumns |
Short Integer |
numberofcardrows |
numberofcardrows |
Short Integer |
racksides |
racksides |
String |
slotorientation |
slotorientation |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Patch Panel Card
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
defaultheight |
defaultportheight |
Short Integer |
defaultwidth |
defaultportwidth |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
numberofportcolumns |
numberofportcolumns |
Short Integer |
numberofportrows |
numberofportrows |
Short Integer |
racksides |
appearsonracksides |
String |
slotposition |
slotposition |
Short Integer |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Rack
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
defaultslotheight |
defaultslotheight |
Short Integer |
defaultslotwidth |
defaultslotwidth |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
name |
name |
String |
racksides |
sides |
String |
slotcolumns |
slotcolumns |
Short Integer |
slotrows |
slotrows |
Short Integer |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Ribbon
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
ribboncolor |
color |
String |
ribbonname |
colorname |
String |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
ribbonnumber |
number |
Integer |
ribbonposition |
ribbonposition |
Integer |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Ribbon Strand
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
available |
available |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fibercolor |
fibercolor |
String |
fibername |
fibername |
String |
fibernumber |
fibernumber |
Long Integer |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
modetype |
modetype |
String |
status |
status |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Shelf
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
numberofdevicecolumns |
numberofdevicecolumns |
Short Integer |
numberofdevicerows |
numberofdevicerows |
Short Integer |
rackposition |
rackposition |
Short integer |
shelfheight |
shelfheight |
Short Integer |
shelfname |
shelfname |
String |
shelfwidth |
shelfwidth |
Short Integer |
sides |
sides |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Split In
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
height |
There is no equivalent field in Fiber Manager XI. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any functionality in Fiber Manager XI. |
|
portname |
There is no equivalent field in Fiber Manager XI. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any functionality in Fiber Manager XI. |
|
portnumber |
portnumber |
String |
portpositiononsplitter |
portpositiononsplitter |
Short Integer |
porttype |
porttype |
String |
sides |
There is no equivalent field in Fiber Manager XI. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any functionality in Fiber Manager XI. |
|
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
width |
There is no equivalent field in Fiber Manager XI. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any functionality in Fiber Manager XI. |
Split Out
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
height |
There is no equivalent field in Fiber Manager XI. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any functionality in Fiber Manager XI. |
|
impliedalignment |
impliedalignment |
|
impliedconnectionsourceguid |
impliedconnectionsourceguid |
|
portname |
There is no equivalent field in Fiber Manager XI. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any functionality in Fiber Manager XI. |
|
portnumber |
portnumber |
String |
portpositiononsplitter |
portpositiononsplitter |
Short Integer |
porttype |
porttype |
String |
sides |
There is no equivalent field in Fiber Manager XI. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any functionality in Fiber Manager XI. |
|
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
width |
There is no equivalent field in Fiber Manager XI. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any functionality in Fiber Manager XI. |
Strand
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
available |
available |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fibercolor |
fibercolor |
String |
fibername |
fibername |
String |
fibernumber |
fibernumber |
Long Integer |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
modetype |
modetype |
String |
status |
status |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Active Device
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
activedeviceheight |
deviceheight |
Short Integer |
activedevicename |
devicename |
String |
activedeviceposition |
deviceposition |
Short Integer |
activedevicewidth |
devicewidth |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
numberofportcolumns |
numberofportcolumns |
Short Integer |
numberofportrows |
numberofportrows |
Short Integer |
sides |
sides |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Active Common Port
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
height |
height |
Short Integer |
lambdamax |
lambdamax |
Double |
lambdamin |
lambdamin |
Double |
portname |
portname |
String |
portnumber |
portnumber |
Short Integer |
portpositionondevice |
portpositionondevice |
Short Integer |
sides |
sides |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
width |
width |
Short Integer |
Active Split Port
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
height |
height |
Short Integer |
impliedalignment |
impliedalignment |
Short Integer |
impliedconnectionsourceguid |
impliedconnectionsourceguid |
GUID |
lambdamax |
lambdamax |
Double |
lambdamin |
lambdamin |
Double |
portname |
portname |
String |
portnumber |
portnumber |
Short Integer |
portpositionondevice |
portpositionondevice |
Short Integer |
porttype |
porttype |
String |
sides |
sides |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
width |
width |
Short Integer |
Back Port
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
defaultheight |
defaultheight |
Short Integer |
defaultwidth |
defaultwidth |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
impliedconnectionsourceguid |
impliedconnectionsourceguid |
GUID |
portname |
portname |
String |
portnumber |
portnumber |
Short Integer |
portpositiononcard |
portpositiononcard |
Short Integer |
porttype |
porttype |
String |
racksides |
sidesofrackshownon |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Buffer Tube
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
buffertubecolor |
buffertubecolor |
String |
buffertubename |
buffertubename |
String |
buffertubenumber |
buffertubenumber |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Bundle
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
-
In Fiber Manager 10.x, the F_RIBBON table included all information for both bundles and ribbons. Thus, during migration, you need to migrate data specific to the ribbons out of the F_RIBBON table and into the Ribbon table in Fiber Manager XI, and you need to migrate data specific to the bundles out of the F_RIBBON table and into the Bundle table in Fiber Manager XI.
-
Because these were previously stored in a single table in Fiber Manager 10.x, for Fiber Manager XI you also need to create the parent/child relationships with appropriate fiberparent GUIDs between the Bundle and Ribbon tables. In other words, because in Fiber Manager 10.x it was a single table of F_RIBBON (no relationship) but in Fiber Manager XI it is now two related tables of Bundle > Ribbon, a new relationship has been inserted. This new relationship does not have any pre-existing GUIDs to track who is related to whom, and these GUIDs need to be created.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
bundlecolor |
bundlecolor |
String |
bundlename |
bundlename |
String |
bundlenumber |
bundlenumber |
Integer |
bundleposition |
bundleposition |
Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Circuit
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Circuit Component
There is no equivalent object table in Fiber Manager XI. If you want to preserve this table, you can, but it does not bear any functionality in Fiber Manager XI.
Connection
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
aclassmodelname |
aclassmodelname |
String |
aconnectionobjectglobalid |
aconnectionobjectglobalid |
GUID |
attentuation1310 |
attentuation1310 |
Double |
attentuation1550 |
attentuation1550 |
Double |
bclassmodelname |
bclassmodelname |
String |
bconnectionobjectglobalid |
bconnectionobjectglobalid |
GUID |
containerclassmodelname |
containerclassmodelname |
String |
containerglobalid |
containerglobalid |
GUID |
globalid |
globalid |
Global ID |
splicetype |
splicetype |
String |
traynumber |
traynumber |
Short Integer |
Dev
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
deviceheight |
defaultdeviceheight |
Short Integer |
devicewidth |
defaultdevicewidth |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
name |
name |
String |
numberofportcolumns |
numberofportcolumns |
Short Integer |
numberofportrows |
numberofportrows |
Short Integer |
rackposition |
positiononrack |
Short Integer |
racksides |
sidesofrackshownon |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Dev Port
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
height |
defaultheight |
Short Integer |
lambdamax |
lambdamax |
Double |
lambdamin |
lambdamin |
Double |
portname |
There is no equivalent field in Fiber Manager XI. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any functionality in Fiber Manager XI. |
|
portnumber |
portnumber |
Long Integer |
portstatus |
portstatus |
Short Integer |
porttype |
porttype |
String |
racksides |
sideofrackshownon |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
width |
defaultwidth |
Short Integer |
Front Port
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
defaultheight |
defaultheight |
Short Integer |
defaultwidth |
defaultwidth |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
portname |
portname |
String |
portnumber |
portnumber |
Long Integer |
portpositiononcard |
portpositiononcard |
Short Integer |
porttype |
porttype |
String |
racksides |
sidesofrackshownon |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Passive Device
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
deviceheight |
deviceheight |
Short Integer |
devicename |
devicename |
String |
deviceposition |
deviceposition |
Long Integer |
devicewidth |
devicewidth |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
sides |
sides |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Passive Device Common Port
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
height |
height |
Short Integer |
lambdamax |
lambdamax |
Double |
lambdamin |
lambdamin |
Double |
portname |
portname |
String |
portnumber |
portnumber |
Short Integer |
portpositionondevice |
portpositionondevice |
Short Integer |
portstatus |
portstatus |
Short Integer |
porttype |
porttype |
String |
sides |
sides |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
width |
width |
Short Integer |
Passive Device Split Port
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
height |
height |
Short Integer |
impliedalignment |
impliedalignment |
Short Integer |
impliedconnectionsourceguid |
impliedconnectionsourceguid |
GUID |
lambdamax |
lambdamax |
Double |
lambdamin |
lambdamin |
Double |
portname |
portname |
String |
portnumber |
portnumber |
Short Integer |
portpositionondevice |
portpositionondevice |
Short Integer |
porttype |
porttype |
String |
sides |
sides |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
width |
width |
Short Integer |
Patch Panel (PP)
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
defaultcardwidth |
defaultcardwidth |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
name |
name |
String |
numberofcardcolumns |
numberofcardcolumns |
Short Integer |
numberofcardrows |
numberofcardrows |
Short Integer |
racksides |
racksides |
String |
slotorientation |
slotorientation |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Patch Panel Card
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
defaultheight |
defaultportheight |
Short Integer |
defaultwidth |
defaultportwidth |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
numberofportcolumns |
numberofportcolumns |
Short Integer |
numberofportrows |
numberofportrows |
Short Integer |
racksides |
appearsonracksides |
String |
slotposition |
slotposition |
Short Integer |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Rack
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
defaultslotheight |
defaultslotheight |
Short Integer |
defaultslotwidth |
defaultslotwidth |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
name |
name |
String |
racksides |
sides |
String |
slotcolumns |
slotcolumns |
Short Integer |
slotrows |
slotrows |
Short Integer |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Ribbon
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
-
In Fiber Manager 10.x, the F_RIBBON table included all information for both bundles and ribbons. Thus, during migration, you need to migrate data specific to the ribbons out of the F_RIBBON table and into the Ribbon table in Fiber Manager XI, and you need to migrate data specific to the bundles out of the F_RIBBON table and into the Bundle table in Fiber Manager XI.
-
Because these were previously stored in a single table in Fiber Manager 10.x, for Fiber Manager XI you also need to create the parent/child relationships with appropriate fiberparent GUIDs between the Bundle and Ribbon tables. In other words, because in Fiber Manager 10.x it was a single table of F_RIBBON (no relationship) but in Fiber Manager XI it is now two related tables of Bundle > Ribbon, a new relationship has been inserted. This new relationship does not have any pre-existing GUIDs to track who is related to whom, and these GUIDs need to be created.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
ribboncolor |
color |
String |
ribbonname |
colorname |
String |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
ribbonnumber |
number |
Integer |
ribbonposition |
ribbonposition |
Integer |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Ribbon Strand
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
-
In Fiber Manager 10.x, all fiber strands (regardless if they were organized within a buffer tube or a bundle > ribbon), were saved in the F_FIBER table. In Fiber Manager XI, fiber strands that are organized within a buffer tube are saved in the Strand table, and fiber strands that are organized in bundles > ribbons are saved in the Ribbon Strand table.
-
Thus, during data migration to Fiber Manager XI, ensure the strands are separated in the F_FIBER table so they arrive in their proper Fiber Manager XI table.
-
Further, because the Fiber Manager 10.x hierarchy was F_RIBBON > F_FIBER and in Fiber Manager XI is it Bundle > Ribbon > Ribbon Strand, ensure the existing GUIDs are transferred to the appropriate levels of the hierarchy to maintain the relationships.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
available |
available |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fibercolor |
fibercolor |
String |
fibername |
fibername |
String |
fibernumber |
fibernumber |
Long Integer |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
modetype |
modetype |
String |
status |
status |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Shelf
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
numberofdevicecolumns |
numberofdevicecolumns |
Short Integer |
numberofdevicerows |
numberofdevicerows |
Short Integer |
rackposition |
rackposition |
Short integer |
shelfheight |
shelfheight |
Short Integer |
shelfname |
shelfname |
String |
shelfwidth |
shelfwidth |
Short Integer |
sides |
sides |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
Split In
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
height |
There is no equivalent field in Fiber Manager XI. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any functionality in Fiber Manager XI. |
|
portname |
There is no equivalent field in Fiber Manager XI. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any functionality in Fiber Manager XI. |
|
portnumber |
portnumber |
String |
portpositiononsplitter |
portpositiononsplitter |
Short Integer |
porttype |
porttype |
String |
sides |
There is no equivalent field in Fiber Manager XI. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any functionality in Fiber Manager XI. |
|
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
width |
There is no equivalent field in Fiber Manager XI. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any functionality in Fiber Manager XI. |
Split Out
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
height |
There is no equivalent field in Fiber Manager XI. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any functionality in Fiber Manager XI. |
|
impliedalignment |
impliedalignment |
|
impliedconnectionsourceguid |
impliedconnectionsourceguid |
|
portname |
There is no equivalent field in Fiber Manager XI. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any functionality in Fiber Manager XI. |
|
portnumber |
portnumber |
String |
portpositiononsplitter |
portpositiononsplitter |
Short Integer |
porttype |
porttype |
String |
sides |
There is no equivalent field in Fiber Manager XI. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any functionality in Fiber Manager XI. |
|
thisfiberclassmodelname |
thisfiberclassmodelname |
String |
width |
There is no equivalent field in Fiber Manager XI. If you want to preserve these attributes, you can map them to a custom field, but they do not bear any functionality in Fiber Manager XI. |
Strand
The fields in the table below are the required fields in the Fiber Manager 10.x data model. With a couple exceptions, all of the Fiber Manager 10.x fields have an equivalent field in the Fiber Manager XI data model. Your company likely added other fields to your data model, and these fields vary by company. Thus, they are not represented in the table below. Most likely, there is a logical field in the Fiber Manager XI data model to accept your additional fields. Work with your implementation team to determine the best fit.
-
In Fiber Manager 10.x, all fiber strands (regardless if they were organized within a buffer tube or a bundle > ribbon), were saved in the F_FIBER table. In Fiber Manager XI, fiber strands that are organized within a buffer tube are saved in the Strand table, and fiber strands that are organized in bundles > ribbons are saved in the Ribbon Strand table.
-
Thus, during data migration to Fiber Manager XI, ensure the strands are separated in the F_FIBER table and arrive in their proper Fiber Manager XI table.
Fiber Manager 10.x Field |
Equivalent Fiber Manager XI Field |
Type |
---|---|---|
available |
available |
Short Integer |
fiberchildclassmodelname |
fiberchildclassmodelname |
String |
fibercolor |
fibercolor |
String |
fibername |
fibername |
String |
fibernumber |
fibernumber |
Long Integer |
fiberparent |
fiberparent |
GUID |
fiberparentclassmodelname |
fiberparentclassmodelname |
String |
globalid |
globalid |
Global ID |
modetype |
modetype |
String |
status |
status |
String |
thisfiberclassmodelname |
thisfiberclassmodelname |
String |