TeSys™ Ultra Starter Components

Refer to Catalog MKTED210011EN

TeSys™ Ultra Selection

For detailed information about TeSys™ Ultra,
visit www.se.com/us/en/.

Power Base

The NEMA style TeSys Ultra motor starter is an integrated product—simple to choose and to install—consisting of a control unit snapped into a power base. TeSys Ultra can be configured to fit specific applications as well. The NEMA style TeSys Ultra starter uses the same optional accessories—reverser, current limiter, predictive maintenance options, and communication options—as the IEC TeSys Ultra.

Selecting a NEMA TeSys Ultra Motor Starter in Three Steps

Step 1. Select Power Base

Control
Connection

NEMA Size

Max. hp, Three Phase

Max. hp,
Single Phase

Power Bases

200/208 V

220/240 V

460 V

575/600 V

120 V

240 V

Catalog Number

With screw terminations

1

7.5

7.5

10

10

2

3

LUB32NR

Voltage Codes

Volts

24

48–72

110–240

DC

BL[1]

AC

B

DC or AC

ES[2]

FU

Step 2. Select Control Unit [3]

Setting Range
A

Standard 3-phase
Class 10 trip [4]

Advanced 3-Phase
Class 10 trip [4]

Advanced Single-Phase
Class 10 trip [4]

Advanced 3-Phase
Class 20 trip [4]

0.15–0.6

LUCAX6••

LUCBX6••

LUCCX6••

LUCDX6••

0.3–1.4

LUCA1X••

LUCB1X••

LUCC1X••

LUCD1X••

1.25–5.0

LUCA05••

LUCB05••

LUCC05••

LUCD05••

3–12

LUCA12••

LUCB12••

LUCC12••

LUCD12••

4.5–18

LUCA18••

LUCB18••

LUCC18••

LUCD18••

8–32

LUCA32••

LUCB32••

LUCC32••

LUCD32••

Control Unit

Auxiliary Contact

Step 3. Select Auxiliary Contacts (optional)

Auxiliary Contact Blocks

Terminals

Contact Indicates

Normal Contact Status

Contact State for Each Mode [5]

Catalog Number

Off

Ready

Run

Short Circuit Trip

Overload Trip (Manual Reset)

Overload Trip (Remote/Auto Reset) [6]

Screw

Ready condition

N.O.

O

I

I

O

O

I

LUA1C11

Fault condition

N.C.

I

I

I

O

O

I

Screw

Ready condition

N.O.

O

I

I

O

O

I

LUA1C20

Fault condition

N.O.

O

O

O

I

I

O

TeSys Ultra Auxiliary Contact Function Modules

Terminals

Contact Indicates

Normal Contact Status

Catalog Number

Screw

Power pole status

2 N.O.

LUFN20

Screw

Power pole status

1 N.O. and 1 N.C.

LUFN11

Screw

Power pole status

2 N.C.

LUFN02

E164862

CCN NLDX

LR43364

Class 3211 08

 

TeSys Ultra Accessories

Accessories for LUB32NR

Quick Description

For details and selection, see pages:

Current limiter

Increases the breaking capacity to 130kA @ 460 V

18-25

Reverser

Stacked or side mounted (LU6MB0•• [4] only)

18-25

Line phase barrier

Required for use as a self-protected combination starter (UL508 Type E)

18-25

Multifunction control unit

Has functions for monitoring and predictive maintenance

18-25

Function modules

Fault differentiation, thermal overload, motor load indication

18-25

Communication modules

Integrates into existing networks, major protocols available

18-26

Soft starter + TeSys™ Ultra

Use Altistart U01Soft Starter with TeSys™ Ultra

18-42

Power bus bars

TeSys™ Ultra cabling accessory

18-26

Control circuit accessories

Control circuit contact block, external handles, and control circuit filters

18-26

Accessories and Dimensions: See Section 18.

Footnotes

  1. DC voltage with range of 0.90 to 1.10 of nominal.
  2. 48–72 Vdc; 48 Vac.
  3. The control unit contains solid-state overload relay and control power source for TeSys Ultra. For more details on the different control units, their functions, and placement on the power base see Section 18.
  4. Complete the catalog number by adding the appropriate voltage code from Voltage Codes. For example: LUCAX6FU.
  5. I = closed contact; O = open contact.
  6. Requires a multifunction or advanced control unit, plus fault differentiation module LUFDDA10.

Was this helpful?