Accessories
Refer to Catalog MKTED210011EN
Auxiliary Contacts, Time Delay, Mechanical Latch
Standard, Instantaneous Auxiliary Contact Blocks
Snap-On Mounting |
Number of Contacts |
Composition |
Catalog Number |
|
---|---|---|---|---|
N.O. |
N.C. |
|||
To front of Size 00–2 or To right side of Size 3–7 |
4 |
2 |
2 |
|
1 |
3 |
|||
4 |
0 |
|||
0 |
4 |
|||
3 |
1 |
|||
2 [2] |
2 [2] |
|||
2 |
1 |
1 |
||
2 |
0 |
|||
0 |
2 |
|||
To left side of Size 3–7 |
1 |
1 |
0 |
|
0 |
1 |
|||
To side of Size 00–2 |
2 |
1 |
1 |
|
2 |
0 |
Instantaneous Blocks with Dust-Tight Auxiliary Contacts (IP54)
NEMA 12
Snap-On Mounting |
Standard Contacts |
Dust-Tight Contacts |
Catalog Number |
||
---|---|---|---|---|---|
N.O. |
N.C. |
N.O. |
N.C. |
||
To front of Size 00–2 or To right side of Size 3–7 |
— |
— |
2 |
— |
|
2 |
— |
2 |
— |
||
1 |
1 |
2 |
— |
||
— |
— |
2 |
— |
Pneumatic Time Delay Contact Blocks
Snap-On Mounting |
Time Delay Contacts |
Type |
Range of Time Delay |
Catalog Number [5] |
|
---|---|---|---|---|---|
N.O. |
N.C. |
||||
To
front of or To
right side of |
1 |
1 |
On energization |
0.1 to 3 s [6] |
|
0.1 to 30 s |
|||||
10 to 180 s |
|||||
1 to 30 s [7] |
|||||
1 |
1 |
On de-energization |
0.1 to 3 s [6] |
||
0.1 to 30 s |
|||||
10 to 180 s |
Mechanical Latch Blocks with Manual or Electrical Unlatch
Front snap-on mounting onto |
Application |
Catalog Number |
---|---|---|
Size 00–2 |
For silent operation and energy conservation |
Coil Voltage Codes for LA6DK Mechanical Latch Blocks
Volts |
24 |
120 |
208 |
240 |
480 |
---|---|---|---|---|---|
AC or DC [10] |
B |
F |
L |
M |
R |
TeSys™ N Reversing Contactors: Field Assembly
Contactors
Coil Suppressors and Cabling Accessories
RC Coil Suppressor
-
Transient voltage limited to 300% of nominal voltage, maximum.
-
Oscillating frequency is limited to 400 Hz maximum. Slight increase in drop-out time (1.2 to 2 times normal).
Resistor/Capacitor Circuit (RC) for Reduction of Electrical Noise in AC Contactor Coils
Installed by |
Mounting on |
Operating Voltage |
Catalog Number |
---|---|---|---|
Snapping into the cavity on the right side without tools [13] |
Size 00–1 |
24 V |
|
120 V |
|||
120–240 V |
|||
Snap-on mounting, and connection without tools to the contactor coil terminals |
Size 2 |
24 V |
|
120 V |
|||
120-240 V |
Varistor Coil Suppressor
-
Transient voltage value limited to 200% of nominal voltage, maximum.
-
Maximum reduction of transient voltage peaks. Slight increase in drop-out time (1.1 to 1.5 times normal).
Varistor (Peak Limiting) for Reduction of Electrical Noise in AC Contactor Coils
Installed by |
Mounting on |
Operating Voltage |
Catalog Number |
---|---|---|---|
Snapping into the cavity on the right side without tools[13] |
Size 00–1 |
24 V |
|
120 V |
|||
120–240 V |
|||
Snap-on mounting, and connection without tools to the contactor coil terminals |
Size 2 |
24 V |
|
120 V |
|||
120-240 V |
Diode Coil Suppressor
Bidirectional Diode Coil Suppressor
-
Protection provided by limiting the transient voltage to 2 Uc max.
-
Maximum reduction of transient voltage peaks.
Bidirectional Peak Limiting Diode
Installed by |
Mounting on |
Operating Voltage |
Catalog Number |
---|---|---|---|
Snapping into the cavity on the right side of the contactor [13] |
Size 00–1[14] |
24 (AC only) |
|
Clip-on front mounting
and connection without tools |
Size 2 |
24 V |
|
120 V |
|||
208–240 V |
TeSys N Cabling Accessories
Cabling Accessories
Usage |
Mounting on |
Operating Voltage |
Catalog Number |
|
---|---|---|---|---|
For adapting existing wiring to a new product or for use with top-mounting accessory. |
Size 00–1, AC only |
Without coil suppression |
||
With coil |
24 V |
|||
120 V |
||||
120-240 V |
||||
For adapting existing wiring to a new product or for use with top-mounting accessory |
Size 2, AC only |
— |
Electronic Timers and Interface Modules
The following accessories require use of cabling accessories (LAD4BB●●) for proper mounting. See TeSys N Cabling for illustration.
The solid-state Electronic Serial Timer Modules in Electronic Serial Timer Modules delay the energizing of the contactor coil, and feature built-in varistor surge suppression.
Electronic Serial Timer Modules
Type |
Operational Voltage 24–250 Vac |
Time Delay |
Catalog Number |
---|---|---|---|
On-delay |
Size 00–2 |
0.1–2 s |
|
1.5–30 s |
|||
25–500 s |
The Interface Modules in Interface Modules allow the contactor
coils to be energized from low voltage and low current level signals.
They come in mechanical relay and solid-state versions. The relay
plus manual operation versions include a lever for manually turning
the contactor on and off. When a module receives a low-level signal,
it allows the separate-sourced control voltage to flow to the contactor
coil. It saves space and wiring time compared to conventional interposing
relays.
Interface Modules [15]
Interface Type |
Operational Voltage 24–250 Vac |
Input Voltage |
Catalog Number |
---|---|---|---|
Relay |
Size 00–2 |
24 Vdc |
|
Relay Plus |
Size 00–2 |
24 Vdc |
|
Solid State |
Size 00–2 |
24 Vdc |
Lugs and Lug Kits [16]
TeSys N Contactor |
Lugs |
Lug Kits[17] |
Cable size AWG range |
|
---|---|---|---|---|
Line Size |
Load Side |
|||
Size 3 |
3 each DZ2FF1 |
3 each DZ2FF1 |
DZ2FF6 |
14 to 2/0 |
Size 4 |
3 each DZ2FG1 |
3 each DZ2FG1 |
DZ2FG6 |
6 to 3/0 |
Size 5 |
3 each DZ2FJ1 |
3 each DZ2FJ1 |
DZ2FJ6 |
4 to 500 MCM |
Size 6 |
3 each DZ2FK1 |
3 each DZ2FK1 |
DZ2FK6 |
2 x 2 to 600 MCM |
Size 7 |
1 each
DZ2FL1 |
1 each
DZ2FL1 |
DZ2FL6 |
3 x 2 to 600 MCM |
TeSys Safety-Chain Identification System
Description |
Compatibility |
Package Qty |
Catalog Number |
---|---|---|---|
Red retrofit contactor safety cover |
Size 00–2 |
10 |
LAD9ET1S |
Red auxiliary contact block, 2 N.O. + 2 N.C. |
Size 00–2 |
1 |
LADN22S |