Class 9999 / Refer to Catalog 9999CT9701
Power Pole Adders
One single- or double-circuit power pole kit can be field added to a basic two- or three-pole Type S contactor or starter Sizes 0, 1 and 2, or lighting contactors 30–60 A. See Power Pole Adders—Selection for selection. The ratings for these power pole adders correspond to the NEMA contact ratings found on Replacement AC Magnet Coils. A two- or three-pole contactor or starter accepts only one single- or double-circuit unit. A power pole cannot be used on four- or five-pole devices, or on devices that are mechanically interlocked.
When adding a power pole to a Size 0 or 1 device, remove the return springs according to the instructions that come with the device.
When adding a power pole to a Size 2 or 60 A device, a coil change is required. Select a four- or five-pole coil from Replacement AC Magnet Coils, or specify Form Y118 as noted in the footnote below.
When adding Size 0–2 power pole kits to a Size 3–7 or 100–800 A device, an adapter bracket is required. The Class 9999 Types SB6–SB15 power pole kits are suitable for copper wire only.
Power Pole Adders—Selection
For Use With |
Power Pole Adder Kit |
||
---|---|---|---|
Type |
Size |
Description |
Class 9999 Type |
SB, SC, and SM |
0, 1, and 30 A |
One N.O. power pole adder |
|
SD |
2 |
— |
|
SP |
60 A |
— |
|
SB, SC, and SM |
0, 1, and 30 A |
One N.C. power pole adder |
— |
SD |
2 |
||
SP |
60 A |
— |
|
SB, SC, and SM |
0, 1, and 30 A |
One N.O. and one N.C. |
— |
SD |
2 |
||
SP |
60 A |
— |
|
SB, SC, and SM |
0, 1, and 30 A |
Two N.O. power pole adders |
|
SD |
2 |
— |
|
SP |
60 A |
— |
|
SB, SC, and SM |
0, 1, and 30 A |
Two N.C. power pole adders |
— |
SD |
2 |
||
SP |
60 A |
— |
|
SE–SJ |
3–7 |
Adapter bracket |
— |
Control Circuit Fuse Holder
The control circuit fuse holder is designed to be used on Type S contactors and starters, Sizes 00–7, when either one or two control circuit fuses, 600 V maximum, are required. The Type SF4 fuse holders will accept standard 600 V Bussmann Type KTK or equivalent fuses (13/32" x 1-1/2"); 6 A maximum.
Control Circuit Fuse Holder—Selection
Description (fuses not included) |
Class 9999 |
---|---|
Type |
|
Single Fuse Unit |
— |
Single Fuse Unit for Class CC Fuse |
— |
Two Fuse Unit |
|
Two Fuse Unit for Class CC Fuses |
— |
Transient Suppression Module
How to Order
To Order Specify: |
Catalog Number |
|
---|---|---|
|
Class |
Type |
9999 |
SM1 |
The transient suppression module is designed to be used where the transient voltage, generated when opening the coil circuit, interferes with the proper operation of nearby integrated or solid-state control circuits. The module consists of an RC circuit and is designed to suppress the coil voltage transients to approximately 200% of peak coil supply voltage. The module is wired across the coil for Type S, Sizes 00–5 and is designed for coil voltages of 120 V only.