NEMA Types 1, 4, 12/3R, and Oversize
Class 9991 / Refer to Catalog 9999CT9701
Enclosure Selection
NEMA 1, 4, and Oversized Enclosures
For the Addition
of a Control Circuit Transformer
The Class 9991 enclosures listed in NEMA 1, 4, and 12 Enclosures accept an open type Class 8502 or 8536 Type S, NEMA Size 0, 1, 1P, or 2 contactor or starter along with a fused control circuit transformer (Form F4T) to allow field assembly of enclosed controllers. In the cover of the Class 9991 Type SCG1 enclosure, knock-outs are provided for field addition of Class 9999 cover-mounted control units. All other Class 8502 & 8536 enclosures include a panel with space and drilling for an open-type device and a fused control circuit transformer. In addition, three closing plates are included in each cover for easy installation of Class 9001 Type K or SK control units.
Oversized enclosures for open type Class 8903 Type L & LX, 20 A and Type S, 30 and 60 A electrically and mechanically held lighting contactors include a panel with space and drilling for an open- type contactor and fused control circuit transformer (Form F4T) and/or an auxiliary relay for use with single pole pilot devices (Form R6). When an auxiliary relay is required, use a Class 8501 Type XO11 relay. Three closing plates are provided as standard for easy installation of Class 9001 Type K or SK control units. Note: A Class 9991 Type SCG1 NEMA 1 separate enclosure can also be used for Class 8903 Type SMO, 30 A electrically held lighting contactor if Form F4T (control transformer), with or without cover control units is required.
NEMA 12/3R
Enclosures Modified for Outdoor Applications
(not to
be used in salt air or corrosive environments)
Field Modifications for NEMA 3 dusttight, raintight and sleet resistant outdoor applications are as follows: Watertight conduit hubs or equivalent provision for watertight connection at the conduit entrance shall be used.
Field Modifications for NEMA 3R rainproof and sleet resistant outdoor applications are as follows:
-
Watertight conduit hubs or equivalent provision for watertight connection at the conduit entrance, when the conduit enters at a level higher than the lowest live part, shall be used.
-
Drain holes of 1/8 inch diameter shall be added to the bottom of the enclosure.
Class 9001 Type K oiltight/watertight control units can be easily installed in NEMAs 4, 12, and oversized NEMA 1 separate enclosures provided with closing plates. When installing control units simply remove the closing plates and install the proper Class 9001 Type K components. Convenient control unit kits complete with assembled and pre-wired operators for quick installation are available as Class 9999 user modification kits. See Control Unit Selection Table for contents of each control unit kit. Class 9001 Type SK NEMA 4X corrosion resistant control units may be used as an alternate.
NEMA 1, 4, and 12 Enclosures
For Use With |
Class 9991 Enclosure |
Recommended Class
9070 [1] |
|||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Class |
Type |
NEMA |
No. |
General |
Watertight and |
Dusttight and |
Standard |
Extra Capacity |
|||
Type |
Type |
Type |
Type |
VA |
100 VA |
150 VA |
300 VA |
||||
Type |
Type |
Type |
|||||||||
Magnetic Contactors and Starters [4] |
|||||||||||
8502, |
SAO, SBO, SCO |
00, 0, 1 |
1–3 |
T50 |
50 VA |
T100 [5] |
T150 [5] |
— |
|||
4–5 |
T100 [5] |
100 VA |
— |
T150 [5] |
— |
||||||
SDO |
2 |
2–5 |
— |
— |
T100 |
100 VA |
— |
T150 |
T300 |
||
Lighting Contactors, Non-Combination |
|||||||||||
8903 |
LO, LXO |
20 A |
All |
— |
— |
T50 |
50 VA |
— |
— |
— |
|
T50 |
50 VA |
T100 [5] |
T150 [5] |
— |
|||||||
SMO [6] |
30 A |
1–3 |
T100 [5] |
100 VA |
— |
T150 [5] |
— |
||||
4–5 |
T100 |
100 VA |
— |
T150 |
T300 |
||||||
SPO [6] |
60 A |
2–5 |
Control Unit Selection Table
Class 9999 |
Control Function |
Kit Contents |
|
---|---|---|---|
Class and Type |
Description |
||
SA3 |
Start-Stop Push Button |
1-9001 KR1B |
Start Operator |
SC8 |
Hand-Off-Auto Selector Switch |
1-9001 KS43B |
Selector Operator Switch |
SP28R |
Pilot Light (120 V) |
1-9001 KP1R31 |
Red Pilot Light |