Approximate Dimensions
Class 9991 / Refer to Catalog 9999CT9701
NEMA 1 Enclosures
note
NEMA 1—General Purpose Enclosures (Standard)
Class 9991 |
For Use With |
Dimensions (inches/millimeters) |
Weight |
||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Class |
Type |
Size |
No. of |
Fig. |
Mounting |
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
K |
L |
||
LXG1 |
8903 |
LO , LXO |
20 A |
2–12 |
1 |
— |
7.81 198 |
12.69 322 |
6.03 153 |
— |
1.09 28 |
10.50 267 |
1.09 28 |
1.09 28 |
5.63 143 |
5.75 146 |
1.09 28 |
5.63 143 |
8 |
DPG1 |
8910 |
DP |
20–40 A |
1–2 |
1 |
(4) #10 |
4.85 123 |
8.5 216 |
4.03 102 |
2.42 62 |
.109 3 |
5.75 146 |
.531 13 |
.92 23 |
3.00 76 |
3.75 95 |
— |
— |
2 |
DPA |
1–3 |
||||||||||||||||||
SCG8 |
8536 |
SAO |
00 |
2–3 |
5.56 141 |
||||||||||||||
SBO |
0 |
All |
|||||||||||||||||
DPG2 |
8910 |
DPA |
— |
— |
|||||||||||||||
SDG8 |
8536 |
SDO |
2 |
All |
6.31 160 |
||||||||||||||
DPG3 |
8910 |
DPA |
— |
— |
|||||||||||||||
SEG8 |
8536 |
SEO |
3 |
All |
|||||||||||||||
8911 |
DPSG63 to 93 |
— |
All |
||||||||||||||||
SCG9 |
8702[1] |
SBO, SCO |
0 & 1 |
All |
2 |
(4) 5/16 |
11.88 302 |
11.88 302 |
7.41 188 |
9.75 248 |
1.06 27 |
1.06 27 |
9.75 248 |
1.06 27 |
.31 8 |
— |
— |
— |
16 |
8922 |
ETBC20, ETBC36 |
— |
|||||||||||||||||
SDG9 |
8702[1] |
SCO |
2 |
All |
2 |
(4) 5/16 |
14.88 378 |
14.13 359 |
7.56 192 |
12.75 324 |
1.06 27 |
1.06 27 |
12.00 305 |
1.06 27 |
.31 8 |
— |
— |
— |
24 |
8922 |
ETBC60 |
— |
NEMA 1—General Purpose Enclosures (Oversize)
Class |
For Use With |
|
||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Class |
Type |
Size |
No. of |
Fig. |
Mounting |
A |
B |
C |
D |
E |
F |
G |
H |
I |
Weight |
|
SDG4 |
8502 |
SDO |
2 |
All |
21 |
|||||||||||
8536 |
SDO (Form F4T) |
2 |
All |
7.66 194 |
||||||||||||
9070 |
EO51, EO61, EO71, T750, T1000 |
— |
— |
7.56 192 |
||||||||||||
SCG1 |
8502 |
SBO, SCO (Form F4T) |
0, 1 |
All |
3 |
(4) 9/32 |
6.34 161 |
15.88 403 |
5.19 132 |
4.66 118 |
.84 21 |
14.38 365 |
.75 19 |
.28 7 |
.35 9 |
8 |
8536 |
SBO, SCO (Form F4T) |
0, 1 |
All |
|||||||||||||
8903 |
SMO (E.H.) (Form F4T) |
30 A |
All |
NEMA 1 and 3R Enclosures
note
NEMA 1—General Purpose Enclosures
Class |
For Use With |
Dimensions (See Figure 4) |
Weight |
|||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Class |
Type |
No. of |
A |
B |
C |
D |
E |
F |
G |
H |
J |
L |
||
UE1 |
8501 |
CO |
All |
3.63 92 |
5.28 134 |
3.31 84 |
1.88 48 |
3.63 92 |
1.06 27 |
1.50 38 |
1/4 in.[2] |
1/2–3/4 in. |
2 |
|
UE6 |
8910 |
H, J, K |
All |
4.91 125 |
5.75 146 |
5.53 140 |
3.50 89 |
4.38 111 |
1.56 40 |
2.00 51 |
9/32 in. |
1/2–3/4 in. |
1/2–3/4 in. |
2 |
9050 |
AO |
All |
||||||||||||
HO |
All |
|||||||||||||
UE7 |
8501 |
XO |
2–12, 2–4 |
4.87 124 |
7.79 198 |
7.53 191 |
3.50 89 |
6.38 162 |
1.31 33 |
1.88 48 |
#10 |
1/2–3/4 in. |
4 |
|
XDO |
2–8 |
|||||||||||||
9070 |
EO1,
EO17 |
— |
NEMA 3R—Rainproof and Sleet-Resistant Enclosures
Class |
For Use With |
Dimensions (see Figure 5) |
|||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Class |
Type |
Size |
No. of |
A |
B |
C |
D1 |
D2 |
E |
F |
G1 |
G2 |
H1 |
H2 |
J |
K |
L |
M |
N |
P |
K.O. |
K.O. |
|
SCH2 |
8502 |
SBO , |
0, 1 |
All |
8.83 224 |
12.30 312 |
7.12 181 |
1.39 35 |
1.44 37 |
6.00 152 |
7.50 191 |
2.61 66 |
2.19 56 |
2.08 53 |
2.62 66 |
14.28 363 |
1.37 35 |
1.37 35 |
1.88 48 |
4.38 111 |
1.83 46 |
1/2 3/4 1 |
1/2 3/4 1 |
8903 |
SMO |
30 A |
|||||||||||||||||||||
SDH1 |
8502 |
SDO |
2 |
All |
9.83 250 |
16.30 414 |
8.62 219 |
1.39 35 |
1.44 37 |
7.00 178 |
11.50 292 |
2.61 66 |
2.19 56 |
2.08 53 |
2.62 66 |
16.78 426 |
1.31 33 |
1.75 44 |
2.13 54 |
4.88 124 |
1.83 46 |
1 |
1/2 3/4 |
8903 |
LO |
20 A |
|||||||||||||||||||||
8903 |
SPO |
60 A |
|||||||||||||||||||||
SEH1 |
8502 |
SEO |
3 |
All |
12.63 321 |
25.30 643 |
8.62 219 |
1.39 35 |
1.44 37 |
10.00 254 |
20.60 523 |
2.61 66 |
2.19 56 |
2.08 53 |
2.62 66 |
19.78 502 |
1.31 33 |
2.31 59 |
2.69 68 |
6.38 162 |
1.83 46 |
1 |
1/2 3/4 |
8903 |
SQO |
100 A |
NEMA 4 and 4X Enclosures
note
NEMA 4X—Watertight and Corrosion Resistant Enclosures
Class |
For Use With |
Dimensions (see Figure 6) |
Hub Dia. |
Weight |
|||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Class |
Type |
Size |
No. of |
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
K |
L |
Bot. |
Top & |
||
SCW20 |
8903 |
SMO |
30 A |
All |
6.50 165 |
6.44 164 |
12.13 308 |
.75 19 |
5.00 127 |
8.25 210 |
1.69 43 |
3.34 85 |
10.06 256 |
1.31 33 |
2.13 54 |
.31 8 |
3/4 in. |
1 in. |
7 |
8502 |
SBO, |
0, 1 |
All |
||||||||||||||||
SDW20 |
8903 |
LO, |
20 A |
All |
8.50 216 |
7.06 179 |
13.88 352 |
.75 19 |
7.00 178 |
10.50 267 |
1.69 43 |
3.91 99 |
11.94 303 |
1.63 41 |
2.38 60 |
.31 8 |
3/4 in. |
1-1/2 in. |
13 |
8903 |
SPO |
60 A |
All |
||||||||||||||||
8502 |
SDO |
2 |
All |
NEMA 4—Watertight Enclosures (Standard)
Class |
For Use With |
Dimensions (see Figure 6) |
Hub Dia. |
Weight |
|||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Class |
Type |
Size |
No. of |
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
K |
L |
Bot. |
Top & |
||
SDW11 |
8903 |
LO, LXO |
20 A |
All |
8.13 206 |
7.88 200 |
16.19 411 |
1.56 40 |
5.00 127 |
15.00 381 |
1.09 28 |
1.94 49 |
14.75 375 |
2.00 51 |
2.63 67 |
.31 8 |
3/4 in. |
1-1/2 in. |
18 |
8903 |
SPO |
60 A |
All |
||||||||||||||||
8502 |
SDO |
2 |
All |
||||||||||||||||
8536 |
SDO |
2 |
All |
8.13 206 |
8.56 217 |
16.19 411 |
1.56 40 |
5.00 127 |
15.00 381 |
1.09 28 |
2.88 73 |
14.75 375 |
2.00 51 |
2.63 67 |
.31 8 |
||||
SEW11 |
8903 |
SQO |
100 A |
All |
18.15 461 |
8.77 223 |
32.21 818 |
3.08 78 |
12.00 305 |
30.50 775 |
.86 22 |
3.67 93 |
26.71 678 |
2.58 66 |
3.19 81 |
.44 11 |
3/4 in. |
2-1/2 in. |
51 |
8502 |
SEO |
3 |
All |
||||||||||||||||
8536 |
SEO |
3 |
All |
18.15 461 |
9.58 243 |
32.21 818 |
3.08 78 |
12.00 305 |
30.50 775 |
.86 22 |
4.48 114 |
26.71 678 |
2.58 66 |
3.19 81 |
.44 11 |
||||
SFW11 |
8536 |
SFO |
4 |
All |
|||||||||||||||
8502 |
SFO |
4 |
All |
18.15 461 |
8.77 223 |
32.21 818 |
3.08 78 |
12.00 305 |
30.50 775 |
.86 22 |
3.67 93 |
26.71 678 |
2.58 66 |
3.19 81 |
.44 11 |
NEMA 4—Watertight Enclosures (Oversize)
Class |
For Use With |
Dimensions (see Figure 7) |
Hub Dia. |
Weight |
|||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Class |
Type |
Size |
No. of |
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
K |
L |
Bot. |
Top & |
||
SCW2 |
8702 |
SCO |
1 |
All |
12.63 321 |
7.81 198 |
14.69 373 |
2.56 65 |
7.50 191 |
13.50 343 |
.59 15 |
3.88 98 |
18.41 468 |
1.66 42 |
2.31 59 |
.31 8 |
3/4 in. |
1 in. |
23 |
SCW3 |
8810 |
SBO |
0 |
All |
19 |
||||||||||||||
SCW4 |
8502 |
SBO, SCO |
0, 1 |
All |
24 |
||||||||||||||
SDW2 |
8702 |
SDO |
2 |
All |
14.88 378 |
7.25 184 |
16.19 411 |
2.56 65 |
9.75 248 |
15.00 381 |
.38 10 |
3.88 98 |
20.88 530 |
1.72 44 |
2.63 67 |
.31 8 |
3/4 in. |
1-1/2 in. |
25 |
SDW3 |
8903 |
LO,
LXO |
20 A |
All |
29 |
NEMA 12/3R and Flush Mounting General Purpose Enclosures
note
See Figure: NEMA 12/3R—Dusttight and Driptight Enclosures (Standard)
Class |
For Use With |
Dimensions |
Weight |
||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Class |
Type |
Size |
No. of |
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
||
SDA11 |
8502 |
SDO |
2 |
All |
8.13 206 |
9.28 236 |
16.00 406 |
1.56 40 |
5.00 127 |
15.00 381 |
.50 13 |
3.56 90 |
15.38 391 |
.31 8 |
15 |
8536 |
SDO |
2 |
All |
||||||||||||
8903 |
LO, LXO |
20 A |
All |
||||||||||||
8903 |
SPO |
60 A |
All |
See Figure: NEMA 12/3R—Dusttight and Driptight Enclosures (Oversized)
Class |
For Use With |
Dimensions |
Weight |
||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Class |
Type |
Size |
No. of |
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
||
SCA3 |
8810 |
SBO |
0 |
All |
18 |
||||||||||
SCA4 |
8502 |
SBO,
SCO |
0, 1 |
All |
19 |
See Figure: Flush Mounting General Purpose Enclosures
Class |
For Use With |
Dimensions |
Weight |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Class |
Type |
Size |
No. of |
A |
B |
C |
D |
E |
F |
G |
H |
||
SDF2) |
8903 |
LO, LXO |
20 A |
All |
15.19 386 |
8.94 227 |
7.63 194 |
12.88 327 |
5.44 138 |
10.94 278 |
5.13 130 |
.38 10 |
17 |
SDF2) |
8502 |
SBO, SCO |
0, 1 |
All |
13.44 341 |
7.19 183 |
5.88 149 |
11.13 283 |
4.75 121 |
9.19 233 |
4.50 114 |
.38 10 |
10 |
8536 |
SBO, SCO |
0, 1 |
All |
||||||||||
8903 |
SMO (E.H.) |
30 A |
All |
||||||||||
SDF2) |
8502 |
SDO |
2 |
All |
15.19 386 |
8.94 227 |
7.63 194 |
12.88 327 |
5.44 138 |
10.94 278 |
5.13 130 |
.38 10 |
17 |
8536 |
SDO |
2 |
All |
||||||||||
8903 |
SPO (E.H.) |
60 A |
All |
||||||||||
SEF11 |
8502 |
SEO |
3 |
All |
31.00 787 |
16.75 425 |
14.25 362 |
26.25 667 |
8.00 203 |
— |
— |
.18 5 |
48 |
8903 |
SQO |
100 A |
All |