Approximate Dimensions
Class 8502, 8536 / Refer to Catalog 8502CT9701
Dimensions for Open Type and NEMA 1 Enclosures
note
Dimensions for Class 8502 Open Type
NEMA |
Type |
No. of |
Fig. No. |
Dimensions, in. (Refer to Figure 1) |
Wt |
||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A |
B |
C |
D |
E |
F |
G |
H |
I |
|||||
in. |
in. |
in. |
in. |
in. |
in. |
in. |
in. |
in. |
(lb) |
||||
00 |
SAO |
2–3 |
1 |
3.22 |
4.34 |
4.22 |
1.63 |
1.63 |
0.22 |
3.94 |
— |
— |
4 |
0 |
SBO |
1–3 |
1 |
3.22 |
4.34 |
4.22 |
1.63 |
1.63 |
0.22 |
3.94 |
— |
— |
4 |
1 |
SCO |
4–5 |
4.25 |
4.34 |
4.22 |
1.63 |
2.63 |
0.22 |
3.94 |
— |
— |
4.5 |
|
2 |
SDO |
2–3 |
1 |
4.31 |
5.13 |
4.94 |
2.16 |
2.16 |
0.22 |
4.59 |
0.53 |
1.06 |
6.75 |
4–5 |
5.63 |
5.13 |
4.94 |
2.16 |
3.47 |
0.22 |
4.59 |
0.53 |
1.06 |
8.25 |
|||
3 |
SEO |
2–3 |
1 |
5.47 |
7.09 |
6.5 |
1.88 |
3.53 |
0.31 |
6.03 |
3.25 |
4.75 |
14 |
4–5 |
9.75 |
7.88 |
6.5 |
3.94 |
5.81 |
0.31 |
7 |
4.53 |
9.06 |
22 |
|||
4 |
SFO |
2–3 |
1 |
6 |
8.19 |
6.5 |
2.06 |
3.94 |
0.31 |
7 |
3.59 |
5.31 |
18 |
4–5 |
9.75 |
8.19 |
6.5 |
3.94 |
5.81 |
0.31 |
7 |
4.53 |
9.06 |
22 |
|||
5 |
SGO |
2–3 |
1 |
8.67 |
12.31 |
8.75 |
3.25 |
5.81 |
0.63 |
11.13 |
4.75 |
7.25 |
45 |
6 |
SHO |
2–3 |
1 |
10.55 |
28.06 |
9 |
3.53 |
7.03 |
5.06 |
18.56 |
4.75 |
7.25 |
80 |
Dimensions for 8536 Open Type
NEMA |
Type |
No. of |
Fig. No. |
Dimensions, in. (Refer to Figure 2) |
Wt |
||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A |
B |
C |
D |
E |
F |
G |
H |
I |
|||||
in. |
in. |
in. |
in. |
in. |
in. |
in. |
in. |
in. |
(lb) |
||||
00, 0, 1, 1P |
SAO – SCO |
2–3 |
2 |
3.5 |
6.77 |
4.22 |
0.5 |
1 |
1.61 |
0.2 |
6.25 |
3.97 |
5 |
0, 1 |
SBO–SCO |
4 |
2 |
4.53 |
6.77 |
4.22 |
0.5 |
1 |
2.67 |
0.2 |
6.25 |
3.97 |
5.5 |
2 |
SDO |
2–3 |
2 |
4.31 |
7.81 |
4.94 |
0.5 |
1 |
2.16 |
0.2 |
7.34 |
4.06 |
7.75 |
4 |
5.63 |
7.81 |
4.94 |
0.5 |
1 |
3.47 |
0.2 |
7.34 |
4.06 |
9.25 |
|||
3 |
SEO |
2–3 |
2 |
5.47 |
11.09 |
6.5 |
0.88 |
1.75 |
3.59 |
0.31 |
10.19 |
5.75 |
17 |
4 |
9.75 |
12.13 |
6.5 |
1.81 |
1.75 |
5.81 |
0.31 |
11.19 |
5.75 |
25 |
|||
4 |
SFO |
3 |
2 |
6 |
12.88 |
6.5 |
1.81 |
1.75 |
3.94 |
0.31 |
11.19 |
5.75 |
22 |
4 |
9.75 |
12.88 |
6.5 |
1.81 |
1.75 |
5.91 |
0.31 |
11.19 |
5.75 |
25 |
|||
5 |
SGO |
3 |
2 |
8.56 |
17.56 |
8.75 |
4.75 |
7.25 |
5.38 |
0.63 |
16.38 |
6 |
62 |
6 |
SHO |
3 |
2 |
12.34 |
28.06 |
9 |
4.75 |
7.25 |
5.78 |
5.06 |
18.56 |
8.69 |
85 |
Dimensions for NEMA 1 General Purpose Enclosure
NEMA |
Type |
No. of |
Fig. |
Dimensions, in. |
||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
K |
L |
|||||
8502 |
8536 |
|||||||||||||||
00 |
SAG SBG SCG |
All |
3 |
6 |
10 |
5.28 |
5.56 |
3 |
0.88 |
8.13 |
1 |
0.94 |
4.13 |
5 |
— |
— |
2 |
SDG |
All |
3 |
7.81 |
12.69 |
6.03 |
6.31 |
— |
1.09 |
10.5 |
1.09 |
1.09 |
5.63 |
5.75 |
1.09 |
5.63 |
3 |
SEG |
All |
3 |
11.44 |
21.81 |
8 |
8.38 |
— |
1.53 |
18.75 |
1.53 |
1.53 |
8.38 |
7.75 |
1.53 |
8.38 |
4 |
SFG |
All |
5 |
11.25 |
25.16 |
9 |
9 |
8.59 |
1.25 |
1.25 |
22.31 |
1.44 |
0.44 |
— |
— |
— |
5 |
SGG |
All |
5 |
17.22 |
44.22 |
12.81 |
12.94 |
13 |
2.13 |
2.13 |
40 |
2.13 |
0.56 |
— |
— |
— |
6 |
SHG |
All |
4 |
65.75 |
20.22 |
13.13 |
13.13 |
— |
11 |
64.5 |
2.31 |
5.5 |
— |
— |
— |
— |
Dimensions for NEMA 4X Enclosures
For the dimensions in NEMA 4 and 4X—Stainless Steel Watertight Enclosure and NEMA 4 and 4X—Stainless Steel Watertight Enclosure with Form FF4T, see Figure 6. |
NEMA 4X—Stainless Steel Watertight Enclosure
NEMA |
Class |
Type |
No. of |
Dimensions, in. |
Hub Dia. |
||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bot. Only |
Top & Bot. |
||||||||||||||||
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
K |
L |
W |
X |
||||
0 |
8502 |
SBW |
All |
6.38 |
7.13 |
13.19 |
1.56 |
3.25 |
12 |
0.59 |
1.19 |
11.78 |
1.63 |
2.31 |
0.31 |
3/4'' |
1'' |
SCW |
|||||||||||||||||
8536 |
SBW |
All |
6.38 |
7.81 |
13.19 |
1.56 |
3.25 |
12 |
0.59 |
1.88 |
11.78 |
1.63 |
2.31 |
0.31 |
|||
SCW |
|||||||||||||||||
2 |
8502 |
SDW |
All |
8.13 |
7.88 |
16.19 |
1.56 |
5 |
15 |
1.09 |
1.94 |
14.75 |
2 |
2.63 |
0.31 |
3/4'' |
1-1/2'' |
8536 |
SDW |
All |
8.13 |
8.56 |
16.19 |
1.56 |
5 |
15 |
1.09 |
2.88 |
14.75 |
2 |
2.63 |
0.31 |
|||
3 |
8502 |
SEW |
All |
18.16 |
8.75 |
32.22 |
3.08 |
12 |
30.5 |
0.88 |
3.69 |
26.72 |
2.56 |
3.19 |
0.44 |
3/4'' |
2-1/2'' |
SFW |
|||||||||||||||||
8536 |
SEW |
All |
18.16 |
9.56 |
32.22 |
3.08 |
12 |
30.5 |
0.88 |
4.5 |
26.72 |
2.56 |
3.19 |
0.44 |
3/4" |
2-1/2" |
|
SFW |
|||||||||||||||||
5 |
8502 & 8536 |
SGW |
All |
17.22 |
12.63 |
47.22 |
4.13 |
9 |
46 |
0.63 |
4.59 |
28.31 |
3.13 |
5.75 |
0.56 |
3/4" |
3-1/2" |
NEMA 4X—Stainless Steel Watertight Enclosure with Form FF4T
NEMA |
Class |
Type |
No. of |
Dimensions, in. |
|||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
K |
L |
||||
0 |
8502 |
SBW |
All |
12.63 |
7.13 |
14.69 |
2.56 |
7.5 |
13.5 |
0.59 |
3.19 |
18.81 |
1.66 |
2.31 |
0.31 |
SCW |
|||||||||||||||
8536 |
SBW |
All |
12.63 |
7.81 |
14.69 |
2.56 |
7.5 |
13.5 |
0.59 |
3.88 |
18.41 |
1.66 |
2.31 |
0.31 |
|
SCW |
|||||||||||||||
2 |
8502 |
SDW |
All |
14.88 |
7.56 |
16.31 |
2.56 |
9.75 |
15 |
0.66 |
3.19 |
20.88 |
2 |
2.63 |
0.31 |
8536 |
SDW |
All |
14.88 |
8.25 |
16.31 |
2.56 |
9.75 |
15 |
0.66 |
3.88 |
20.88 |
2 |
2.63 |
0.31 |
|
3 |
8502 |
SEW |
2–3 |
Same as Standard NEMA 4 dimensions, see above. |
|||||||||||
SFW |
2–3 |
||||||||||||||
8536 |
SEW |
2–3 |
Same as Standard NEMA 4 dimensions, see above. |
||||||||||||
SFW |
2–3 |
||||||||||||||
5 |
8502 & 8536 |
SGW |
All |
Same as Standard NEMA 4 dimensions, see above. |
For the dimensions in NEMA 4X—Watertight and Corrosion Resistant Glass Polyester Enclosures, see Figure 7. |
NEMA 4X—Watertight and Corrosion Resistant Glass Polyester Enclosures, Sizes 00–2, without Form FF4T
Size |
Type |
No. of Poles |
Dimensions, in. |
Hub |
Weight (lb) |
||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bot. Only |
Top & Bot. |
||||||||||||||||
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
K |
L |
W |
X |
||||
0, 1 |
SBW |
All |
6.5 |
6.44 |
12.13 |
0.75 |
5 |
8.75 |
1.69 |
3.34 |
10.06 |
1.31 |
2.13 |
0.31 |
0.75 |
1 |
17 |
SCW |
|||||||||||||||||
2 |
SDW |
All |
8.5 |
7.06 |
13.88 |
0.75 |
7 |
10.5 |
1.69 |
3.91 |
11.94 |
1.63 |
2.38 |
0.31 |
0.75 |
1.5 |
22 |
For the dimensions in NEMA 4X—Watertight and Corrosion Resistant Glass Polyester Enclosures with Form FF4T, see Figure 8. |
NEMA 4X—Watertight and Corrosion Resistant Glass Polyester Enclosures
NEMA Size |
Type |
No. of Poles |
Dimensions, in. |
||||
---|---|---|---|---|---|---|---|
A |
B |
C |
E |
F |
|||
0–2 |
SBW |
All |
16.88 |
9.78 |
22.75 |
10.13 |
21.5 |
SCW |
|||||||
SDW |
|||||||
3–4 |
SEW |
All |
25.81 |
11.94 |
33.5 |
18.5 |
32.25 |
SFW |
|||||||
noteDevices with Form FF4T may use a larger enclosure. Consult the Customer Care Center at 1-888-778-2733 for dimensions. |
Dimensions for NEMA 12/3R Enclosures
note
NEMA 12/3R—Dusttight Enclosure
NEMA |
Type |
No. |
Dimensions, in. |
Weight (lb) |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
Class |
Class |
|||
0 |
SBA |
All |
6.38 |
8.53 |
12.75 |
1.56 |
3.25 |
12 |
0.38 |
3.56 |
12.25 |
0.31 |
15 |
16 |
1 |
SCA |
All |
||||||||||||
2 |
SDA |
All |
8.13 |
9.28 |
16 |
1.56 |
5 |
15 |
0.5 |
3.56 |
15.38 |
0.31 |
22 |
23 |
3 |
SEA |
All |
18.16 |
9.56 |
31.5 |
3.08 |
12 |
30.5 |
0.5 |
4.5 |
26.72 |
0.44 |
65 |
68 |
4 |
SFA |
All |
69 |
73 |
||||||||||
5 |
SGA |
All |
17.22 |
13.44 |
47 |
4.13 |
9 |
46 |
0.5 |
5.41 |
28.31 |
0.56 |
160 |
177 |
6 |
SHA |
All |
20.22 |
13 |
65 |
4.13 |
12 |
64 |
0.5 |
6.44 |
30.88 |
0.69 |
228 |
233 |
7 |
SJA |
All |
34.5 |
23.5 |
93 |
Floor Mounting |
— |
— |
NEMA 12/3R—Dusttight Enclosure With Form FF4T
NEMA |
Type |
No. |
Dimensions, in. |
|||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
A |
B |
C |
D |
E |
F |
G |
H |
I |
J |
|||
0 |
SBA |
All |
11.88 |
8 |
13.5 |
2.81 |
6.75 |
12.75 |
0.38 |
3.91 |
18.38 |
0.31 |
1 |
SCA |
All |
||||||||||
2 |
SDA |
All |
14.88 |
8.13 |
16 |
2.56 |
9.75 |
15 |
0.38 |
3.66 |
21.5 |
0.31 |
3 |
SEA |
2–3 |
Same as Standard NEMA 12 dimensions, see above. |
|||||||||
4 |
SFA |
2–3 |
||||||||||
5 |
SGA |
All |
Same as Standard NEMA 12 dimensions, see above. |
|||||||||
6 |
SHA |
All |
Form FF4T comes standard. Refer to Full Voltage Contactors and Starters. |
|||||||||
7 |
SJA |
All |