Class 8538 and 8539 Type S combination starters combine the requirements of motor overload and short circuit protection into one package. These starters are manufactured according to NEMA standards and are UL Listed (some Form numbers may not be listed—contact the Customer Care Center). Class 8538 and 8539 combination starters operate at 600 Vac maximum, 50–60 Hz, and can be provided with one of four overloaded relay styles (refer to General Information).

For Form H30• (special lower-FLA factory-assembled starter combinations with Motor Logic SSOLR protection), see Solid-State Overload Relay Forms.

Class 8538 Fusible Full Voltage Type (Class H Fuse Clips), with Motor Logic SSOLR (replace ●●● with the voltage code) [1]

Ratings

Fuse
Clip
Size
(A)

NEMA 1
General Purpose
Enclosure

NEMA 4X
Watertight and Dusttight Enclosure Stainless Steel (304)
(Sizes 0-5)

NEMA 4X
Watertight, Dusttight and Corrosion Resistant Polyester Enclosure

NEMA 12/3R[2]
Dusttight and Driptight
Industrial Use Enclosure

Motor Voltage
(Starter Voltage)

Max. Hp
Polyphase

NEMA Size

With
External Reset

Without
External Reset

Type [3]

Type [3]

Type [3]

Type [3]

Type [3]

200
(208)

3

0

30

SBG12●●●H30 [4]

SBW12●●●H30 [4]

SBW22●●●H30 [4]

SBA22●●●H30 [4]

SBA12●●●H30 [4]

Schneider Electric offers express shipping for factory modified NEMA Combo Starters. When you need them fast, our Laser™ Delivery program is the answer to getting your product when you need it most. Ask for Laser™ Delivery, then select the product and the modifications you need when you place your order. It’s as easy as that!

5

1

30

SCG12●●●H30 [4]

SCW12●●●H30 [4]

SCW22●●●H30 [4]

SCA22●●●H30 [4]

SCA12●●●H30 [4]

7-1/2

60

SCG13●●●H30 [4]

SCW13●●●H30 [4]

SCW23●●●H30 [4]

SCA23●●●H30 [4]

SCA13●●●H30 [4]

10

2

60

SDG12●●●H30 [4]

SDW12●●●H30 [4]

SDW22●●●H30 [4]

SDA22●●●H30 [4]

SDA12●●●H30 [4]

20

3

100

SEG15●●●H30

SEW15●●●H30

SEW25●●●H30

SEA25●●●H30

SEA15●●●H30

25

200

SEG12●●●H30

SEW12●●●H30

SEA22●●●H30

SEA12●●●H30

40

4

200

SFG15●●●H30

SFW15●●●H30

SFA25●●●H30

SFA15●●●H30

75

5

400

SGG15●●●H30

SGW15●●●H30

SGA25●●●H30

SGA15●●●H30

150

6

600

SHG13●●●H30

SHA23●●●H30

SHA13●●●H30

230
(240)

3

0

30

SBG12●●●H30 [4]

SBW12●●●H30 [4]

SBW22●●●H30 [4]

SBA22●●●H30 [4]

SBA12●●●H30 [4]

5

1

30

SCG12●●●H30 [4]

SCW12●●●H30 [4]

SCW22●●●H30 [4]

SCA22●●●H30 [4]

SCA12●●●H30 [4]

7-1/2

60

SCG13●●●H30 [4]

SCW13●●●H30 [4]

SCW23●●●H30 [4]

SCA23●●●H30 [4]

SCA13●●●H30 [4]

15

2

60

SDG12●●●H30

SDW12●●●H30 [4]

SDW22●●●H30 [4]

SDA22●●●H30 [4]

SDA12●●●H30 [4]

25

3

100

SEG15●●●H30

SEW15●●●H30

SEW25●●●H30

SEA25●●●H30

SEA15●●●H30

30

200

SEG12●●●H30

SEW12●●●H30

SEA22●●●H30

SEA12●●●H30

50

4

200

SFG15●●●H30

SFW15●●●H30

SFA25●●●H30

SFA15●●●H30

100

5

400

SGG15●●●H30

SGW15●●●H30

SGA25●●●H30

SGA15●●●H30

200

6

600

SHG13●●●H30

SHA23●●●H30

SHA13●●●H30

460
(480)

5

0

30

SBG13●●●H30 [4]

SBW13●●●H30 [4]

SBW23●●●H30 [4]

SBA23●●●H30 [4]

SBA13●●●H30 [4]

10

1

30

SCG14●●●H30 [4]

SCW14●●●H30 [4]

SCW24●●●H30 [4]

SCA24●●●H30 [4]

SCA14●●●H30 [4]

15

2

30

SDG16●●●H301

SDW16●●●H301

SDW26●●●H301

SDA26●●●H301

SDA16●●●H301

25

60

SDG14●●●H30 [4]

SDW14●●●H30 [4]

SDW24●●●H30 [4]

SDA24●●●H30 [4]

SDA14●●●H30 [4]

50

3

100

SEG13●●●H30

SEW13●●●H30

SEW23●●●H30

SEA23●●●H30

SEA13●●●H30

100

4

200

SFG13●●●H30

SFW13●●●H30

SFA23●●●H30

SFA13●●●H30

200

5

400

SGG13●●●H30

SGW13●●●H30

SGA23●●●H30

SGA13●●●H30

400

6

600

SHG12●●●H30

SHA22●●●H30

SHA12●●●H30

575
(600)

5

0

30

SBG13●●●H30

SBW13●●●H30

SBW23●●●H30

SBA23●●●H30

SBA13●●●H30

10

1

30

SCG14●●●H30

SCW14●●●H30

SCW24●●●H30

SCA24●●●H30

SCA14●●●H30

15

2

30

SDG16●●●H301

SDW16●●●H301

SDW26●●●H301

SDA26●●●H301

SDA16●●●H301

25

60

SDG14●●●H30

SDW14●●●H30

SDW24●●●H30

SDA24●●●H30

SDA14●●●H30

50

3

100

SEG13●●●H30

SEW13●●●H30

SEW23●●●H30

SEA23●●●H30

SEA13●●●H30

100

4

200

SFG13●●●H30

SFW13●●●H30

SFA23●●●H30

SFA13●●●H30

200

5

400

SGG13●●●H30

SGW13●●●H30

SGA23●●●H30

SGA13●●●H30

400

6

600

SHG12●●●H30

SHA22●●●H30

SHA12●●●H30

note

Some control transformers may require the use of oversized enclosures. Refer to Control Transformer Selection.

Class 8538 Fusible Disconnect Switch Type (Class H Fuse Clips), Single Phase, [5] [6] with Melting Alloy Overload Relays
(see Thermal Unit Selection)

Motor
Voltage

Max.
Hp

Coil
Voltage

NEMA
Size

Poles

Fuse Clip Size
(A)

NEMA 1
General Purpose
Enclosure

NEMA 4 & 4X
Watertight and Dusttight Enclosure
Stainless Steel (304)

NEMA 4X
Watertight, Dusttight and Corrosion Resistant Polyester Enclosure

NEMA 12/3R[2]
Dusttight and Driptight
Industrial Use Enclosure

With
External Reset

Without
External Reset

Type

Type

Type

Type

Type

120

1
2
3

120

0
1
2

2

30
30
60

SBG62V02

SCG62V02

SDG62V02

SBW62V02

SCW62V02

SDW62V02

SBW65V02

SCW65V02

SDW65V02

SBA65V02

SCA65V02

SDA65V02

SBA62V02

SCA62V02

SDA62V02

240

2

3

7-1/2

240

0
1
2

2

30
30
60

SBG62V03

SCG62V03

SDG62V03

SBW62V03

SCW62V03

SDW62V03

SBW65V03

SCW65V03

SDW65V03

SBA65V03

SCA65V03

SDA65V03

SBA62V03

SCA62V03

SDA62V03

For How to Order Information, see Catalog Interpretation, Type S Starters.

Non-Fusible Disconnect Switch Type

3-Pole Polyphase—600 Vac Maximum—50–60 Hz

For Form H30• (special lower-FLA factory-assembled starter combinations with Motor Logic SSOLR protection), see Solid-State Overload Relay Forms.

Class 8538 Non-Fusible Full Voltage Type, Non-Reversing, with Motor Logic SSOLR (replace ●●● with the voltage code) [1]

Ratings

NEMA 1
General Purpose
Enclosure

NEMA 4X
Watertight and
Dusttight Enclosure
Stainless Steel (304)
(Sizes 0–5)

NEMA 4X
Watertight,
Dusttight and
Corrosion Resistant
Polyester Enclosure

NEMA 12/3R[2] Dusttight and Driptight Industrial Enclosure

Motor
Voltage
(Starter
Voltage)

Max. Hp
Polyphase

NEMA
Size

With
External
Reset

Without
External
Reset

Type [3]

Type [3]

Type [3]

Type [3]

Type [3]

200
(208)

3
7-1/2

10
25
40
75
150

0
1
2
3
4
5
6

SBG11●●●H30 [4]

SCG11●●●H30 [4]

SDG11●●●H30 [4]

SEG11●●●H30

SFG11●●●H30

SGG11●●●H30

SHG11●●●H30

SBW11●●●H30 [4]

SCW11●●●H30 [4]

SDW11●●●H30 [4]

SEW11●●●H30

SFW11●●●H30

SGW11●●●H30

SBW21●●●H30 [4]

SCW21●●●H30 [4]

SDW21●●●H30 [4]

SEW21●●●H30

SBA21●●●H30 [4]

SCA21●●●H30 [4]

SDA21●●●H30 [4]

SEA21●●●H30

SFA21●●●H30

SGA21●●●H30

SHA21●●●H30

SBA11●●●H30 [4]

SCA11●●●H30 [4]

SDA11●●●H30 [4]

SEA11●●●H30

SFA11●●●H30

SGA11●●●H30

SHA11●●●H30

230
(240)

3
7-1/2

15
30
50
100
200

0
1
2
3
4
5
6

SBG11●●●H30 [4]

SCG11●●●H30 [4]

SDG11●●●H30 [4]

SEG11●●●H30

SFG11●●●H30

SGG11●●●H30

SHG11●●●H30

SBW11●●●H30 [4]

SCW11●●●H30 [4]

SDW11●●●H30 [4]

SEW11●●●H30

SFW11●●●H30

SGW11●●●H30

SBW21●●●H30 [4]

SCW21●●●H30 [4]

SDW21●●●H30 [4]

SEW21●●●H30

SBA21●●●H30 [4]

SCA21●●●H30 [4]

SDA21●●●H30 [4]

SEA21●●●H30

SFA21●●●H30

SGA21●●●H30

SHA21●●●H30

SBA11●●●H30 [4]

SCA11●●●H30 [4]

SDA11●●●H30 [4]

SEA11●●●H30

SFA11●●●H30

SGA11●●●H30

SHA11●●●H30

460
(480)

5
10
25
50
100
200
400

0
1
2
3
4
5
6

SBG11●●●H30 [4]

SCG11●●●H30 [4]

SDG11●●●H30 [4]

SEG11●●●H30

SFG11●●●H30

SGG11●●●H30

SHG11●●●H30

SBW11●●●H30 [4]

SCW11●●●H30 [4]

SDW11●●●H30 [4]

SEW11●●●H30

SFW11●●●H30

SGW11●●●H30

SBW21●●●H30 [4]

SCW21●●●H30 [4]

SDW21●●●H30 [4]

SEW21●●●H30

SBA21●●●H30 [4]

SCA21●●●H30 [4]

SDA21●●●H30 [4]

SEA21●●●H30

SFA21●●●H30

SGA21●●●H30

SHA21●●●H30

SBA11●●●H30 [4]

SCA11●●●H30 [4]

SDA11●●●H30 [4]

SEA11●●●H30

SFA11●●●H30

SGA11●●●H30

SHA11●●●H30

575
(600)

5
10
25
50
100
200
400

0
1
2
3
4
5
6

SBG11●●●H30

SCG11●●●H30

SDG11●●●H30

SEG11●●●H30

SFG11●●●H30

SGG11●●●H30

SHG11●●●H30

SBW11●●●H30

SCW11●●●H30

SDW11●●●H30

SEW11●●●H30

SFW11●●●H30

SGW11●●●H30

SBW21●●●H30

SCW21●●●H30

SDW21●●●H30

SEW21●●●H30

SBA21●●●H30

SCA21●●●H30

SDA21●●●H30

SEA21●●●H30

SFA21●●●H30

SGA21●●●H30

SHA21●●●H30

SBA11●●●H30

SCA11●●●H30

SDA11●●●H30

SEA11●●●H30

SFA11●●●H30

SGA11●●●H30

SHA11●●●H30

Class 8538 Non-Fusible Disconnect Switch Type, Single Phase, with Melting Alloy Overload Relay [5] [6]
(see Thermal Unit Selection)

Motor
Voltage

Max.
Hp

Coil
Voltage

NEMA
Size

Poles

NEMA 1
General Purpose

Enclosure

NEMA 4 & 4X
Watertight and
Dusttight Enclosure
Stainless Steel (304)

NEMA 4X
Watertight, Dusttight
and Corrosion Resistant
Polyester Enclosure 

NEMA 12/3R[2]
Dusttight and Driptight
Industrial Enclosure

With
External Reset

Without
External Reset

Type

Type

Type

Type

Type

120

1
2
3

120

0
1
2

2

SBG61V02

SCG61V02

SDG61V02

SBW61V02

SCW61V02

SDW61V02

SBW64V02

SCW64V02

SDW64V02

SBA64V02

SCA64V02

SDA64V02

SBA61V02

SCA61V02

SDA61V02

240

2
3
7-1/2

240

0
1
2

2

SBG61V03

SCG61V03

SDG61V03

SBW61V03

SCW61V03

SDW61V03

SBW64V03

SCW64V03

SDW64V03

SBA64V03

SCA64V03

SDA64V03

SBA61V03

SCA61V03

SDA61V03

note

Some control transformers may require the use of oversized enclosures. Refer to Control Transformer Selection.

Coil Voltage Codes

Voltage

Code

60 Hz

50 Hz

 24 [7]
120 [8]
208
240

277
480
600
Specify


110

220


440
550
Specify

V01
V02
V08
V03

V04
V06
V07
V99

note

For voltage codes used with control transformers, see page Selection of Control Circuit Transformers. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is available at no charge.

For How to Order Information, see Catalog Interpretation, Type S Starters.

Fusible Disconnect Switch Type with Class R Fuse Clips

3-Pole Polyphase—600 Vac Maximum—50–60 Hz

For Form H30• (special lower-FLA factory-assembled starter combinations with Motor Logic SSOLR protection), see Solid-State Overload Relay Forms.

Class 8538 Fusible (with Class R Fuse Clips) Full Voltage Type, Non-Reversing, with Motor Logic SSOLR (100,000 AIC Rated) (replace ●●● with the voltage code) [1]

Ratings

NEMA 1
General Purpose
Enclosure

NEMA 4X
Watertight and
Dusttight Enclosure
Stainless Steel (304)
(Sizes 0–5) 

NEMA 4X
Watertight,
Dusttight and
Corrosion
Resistant
Polyester
Enclosure

NEMA 12/3R[2]
Dusttight and
Driptight Industrial
Enclosure

Motor Voltage
(Starter Voltage)

Max.
Hp
Polyphase

NEMA Size

Fuse Clip
Size
(A)

With
External
Reset

Without
External
Reset

Type [9]

Type [9]

Type [9]

Type [9]

Type [9]

200
(208)

3

5

7-1/2

10
20
25
40
75
150

0
1
1
2
3
3
4
5
6

30
30
60
60
100
200
200
400
600

SBG32●●●H30 [4]

SCG32●●●H30 [4]

SCG33●●●H30 [4]

SDG32●●●H30 [4]

SEG35●●●H30

SEG32●●●H30

SFG35●●●H30

SGG35●●●H30

SHG33●●●H30

SBW32●●●H30 [4]

SCW32●●●H30 [4]

SCW33●●●H30 [4]

SDW32●●●H30 [4]

SEW35●●●H30

SEW32●●●H30

SFW35●●●H30

SGW35●●●H30

SBW42●●●H30 [4]

SCW42●●●H30 [4]

SCW43●●●H30 [4]

SDW42●●●H30 [4]

SEW45●●●H30

SBA42●●●H30 [4]

SCA42●●●H30 [4]

SCA43●●●H30 [4]

SDA42●●●H30 [4]

SEA45●●●H30

SEA42●●●H30

SFA45●●●H30

SGA45●●●H30

SHA43●●●H30

SBA32●●●H30 [4]

SCA32●●●H30 [4]

SCA33●●●H30 [4]

SDA32●●●H30 [4]

SEA35●●●H30

SEA32●●●H30

SFA35●●●H30

SGA35●●●H30

SHA33●●●H30

230
(240)

3

5

7-1/2

15
25
30
50
100
200

0
1
1
2
3
3
4
5
6

30
30
60
60
100
200
200
400
600

SBG32●●●H30 [4]

SCG32●●●H30 [4]

SCG33●●●H30 [4]

SDG32●●●H30 [4]

SEG35●●●H30

SEG32●●●H30

SFG35●●●H30

SGG35●●●H30

SHG33●●●H30

SBW32●●●H30 [4]

SCW32●●●H30 [4]

SCW33●●●H30 [4]

SDW32●●●H30 [4]

SEW35●●●H30

SEW32●●●H30

SFW35●●●H30

SGW35●●●H30

SBW42●●●H30 [4]

SCW42●●●H30 [4]

SCW43●●●H30 [4]

SDW42●●●H30 [4]

SEW45●●●H30

SBA42●●●H30 [4]

SCA42●●●H30 [4]

SCA43●●●H30 [4]

SDA42●●●H30 [4]

SEA45●●●H30

SEA42●●●H30

SFA45●●●H30

SGA45●●●H30

SHA43●●●H30

SBA32●●●H30 [4]

SCA32●●●H30 [4]

SCA33●●●H30 [4]

SDA32●●●H30 [4]

SEA35●●●H30

SEA32●●●H30

SFA35●●●H30

SGA35●●●H30

SHA33●●●H30

460
(480)

5
10
15
25
50
100
200
400

0
1
2
2
3
4
5
6

30
30
30
60
100
200
400
600

SBG33●●●H30 [4]

SCG34●●●H30 [4]

SDG36●●●H301

SDG34●●●H30 [4]

SEG33●●●H30

SFG33●●●H30

SGG33●●●H30

SHG32●●●H30

SBW33●●●H30 [4]

SCW34●●●H30 [4]

SDW36●●●H301

SDW34●●●H30 [4]

SEW33●●●H30

SFW33●●●H30

SGW33●●●H30

SBW43●●●H30 [4]

SCW44●●●H30 [4]

SDW46●●●H301

SDW44●●●H30 [4]

SEW43●●●H30

SBA43●●●H30 [4]

SCA44●●●H30 [4]

SDA46●●●H301

SDA44●●●H30 [4]

SEA43●●●H30

SFA43●●●H30

SGA43●●●H30

SHA42●●●H30

SBA33●●●H30 [4]

SCA34●●●H30 [4]

SDA36●●●H301

SDA34●●●H30 [4]

SEA33●●●H30

SFA33●●●H30

SGA33●●●H30

SHA32●●●H30

575
(600)

5
10
15
25
50
100
200
400

0
1
2
2
3
4
5
6

30
30
30
60
100
200
400
600

SBG33●●●H30 [4]

SCG34●●●H30 [4]

SDG36●●●H301

SDG34●●●H30 [4]

SEG33●●●H30

SFG33●●●H30

SGG33●●●H30

SHG32●●●H30

SBW33●●●H30 [4]

SCW34●●●H30 [4]

SDW36●●●H301

SDW34●●●H30 [4]

SEW33●●●H30

SFW33●●●H30

SGW33●●●H30

SBW43●●●H30 [4]

SCW44●●●H30 [4]

SDW46●●●H301

SDW44●●●H30 [4]

SEW43●●●H30

SBA43●●●H30 [4]

SCA44●●●H30 [4]

SDA46●●●H301

SDA44●●●H30 [4]

SEA43●●●H30

SFA43●●●H30

SGA43●●●H30

SHA42●●●H30

SBA33●●●H30 [4]

SCA34●●●H30 [4]

SDA36●●●H301

SDA34●●●H30 [4]

SEA33●●●H30

SFA33●●●H30

SGA33●●●H30

SHA32●●●H30

note

Some control transformers may require the use of oversized enclosures. Refer to Control Transformer Selection.

Class 8538 Fusible Disconnect Switch Type (Class R Fuses), Single Phase with Melting Alloy Overload Relay [5] [6] (see Thermal Unit Selection)

Motor
Voltage

Max.
Hp

Coil
Voltage

NEMA Size

Poles

Fuse Clip
Size
(A)

NEMA 1
General Purpose
Enclosure

NEMA 4X
Watertight
and Dusttight
Enclosure
Stainless Steel

NEMA 4X
Watertight, Dusttight
and Corrosion Resistant
Polyester Enclosure

NEMA 12/3R
Dusttight and Driptight
Industrial Use Enclosure

With
External Reset

Without
External Reset

Type

Type

Type

Type

Type

120

1
2
3

120

0
1
2

2

30
30
60

SBG63V02

SCG63V02

SDG63V02

SBW63V02

SCW63V02

SDW63V02

SBW66V02

SCW66V02

SDW66V02

SBA66V02

SCA66V02

SDA66V02

SBA63V02

SCA63V02

SDA63V02

240

2
3

7-1/2

240

0
1
2

2

30
30
60

SBG63V03

SCG63V03

SDG63V03

SBW63V03

SCW63V03

SDW63V03

SBW66V03

SCW66V03

SDW66V03

SBA66V03

SCA66V03

SDA66V03

SBA63V03

SCA63V03

SDA63V03

Coil Voltage Codes

Voltage

Code

60 Hz

50 Hz

  24[10]
120[11]
208
240
277
480
600
Specify


110

220

440
550
Specify

V01
V02
V08
V03
V04
V06
V07
V99

note

For voltage codes used with control transformers, see Selection of Control Circuit Transformers.
Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is available at no charge.

For How to Order Information, see Catalog Interpretation, Type S Starters.

Full Voltage Type with Motor Logic™ Solid-State Overload Relays

3-Pole Polyphase—600 Vac Maximum—50–60 Hz

For Form H30• (special lower-FLA factory-assembled starter combinations with Motor Logic™ SSOLR protection), see Solid-State Overload Relay Forms.

Class 8538 with Oversized Enclosures (replace ●●● with the voltage code) [1]

Ratings

NEMA 1
General Purpose
Enclosure

NEMA 4X
Watertight and
Dustight Enclosure
Stainless Steel (304)

NEMA 12/3R[2]
Dusttight and Driptight
Industrial Use Enclosure

Motor Voltage
(Starter Voltage)

Max. Hp
Polyphase

NEMA
Size

Fuse Clip
Size (A)

With
External Reset

Without
External Reset

Type [9]

Type [9]

Type [9]

Type [9]

Class 8538 Non-Fusible Disconnect Switch Type—NEMA Size 0–2[12] [6]

200
(208)

3

0

N/A

SBG11S8●●●H30 [4]

SBW11S8●●●H30 [4]

SBA21S8●●●H30 [4]

SBA11S8●●●H30 [4]

7-1/2

1

N/A

SCG11S8●●●H30 [4]

SCW11S8●●●H30 [4]

SCA21S8●●●H30 [4]

SCA11S8●●●H30 [4]

10

2

N/A

SDG11S8●●●H30 [4]

SDW11S8●●●H30 [4]

SDA21S8●●●H30 [4]

SDA11S8●●●H30 [4]

230
(240)

3

0

N/A

SBG11S8●●●H30 [4]

SBW11S8●●●H30 [4]

SBA21S8●●●H30 [4]

SBA11S8●●●H30 [4]

7-1/2

1

N/A

SCG11S8●●●H30 [4]

SCW11S8●●●H30 [4]

SCA21S8●●●H30 [4]

SCA11S8●●●H30 [4]

15

2

N/A

SDG11S8●●●H30 [4]

SDW11S8●●●H30 [4]

SDA21S8●●●H30 [4]

SDA11S8●●●H30 [4]

460
(480)

5

0

N/A

SBG11S8●●●H30 [4]

SBW11S8●●●H30 [4]

SBA21S8●●●H30 [4]

SBA11S8●●●H30 [4]

10

1

N/A

SCG11S8●●●H30 [4]

SCW11S8●●●H30 [4]

SCA21S8●●●H30 [4]

SCA11S8●●●H30 [4]

25

2

N/A

SDG11S8●●●H30 [4]

SDW11S8●●●H30 [4]

SDA21S8●●●H30 [4]

SDA11S8●●●H30 [4]

575
(600)

5

0

N/A

SBG11S8●●●H30 [4]

SBW11S8●●●H30 [4]

SBA21S8●●●H30 [4]

SBA11S8●●●H30 [4]

10

1

N/A

SCG11S8●●●H30 [4]

SCW11S8●●●H30 [4]

SCA21S8●●●H30 [4]

SCA11S8●●●H30 [4]

25

2

N/A

SDG11S8●●●H30 [4]

SDW11S8●●●H30 [4]

SDA21S8●●●H30 [4]

SDA11S8●●●H30 [4]

Class 8538 Fusible Disconnect Switch Type—NEMA Size 0–2[12] [6]

200
(208)

 3

0

30

SBG12S8●●●H30 [4]

SBW12S8●●●H30 [4]

SBA22S8●●●H30 [4]

SBA12S8●●●H30 [4]

5

1

30

SCG12S8●●●H30 [4]

SCW12S8●●●H30 [4]

SCA22S8●●●H30 [4]

SCA12S8●●●H30 [4]

7-1/2

1

60

SCG13S8●●●H30 [4]

SCW13S8●●●H30 [4]

SCA23S8●●●H30 [4]

SCA13S8●●●H30 [4]

10

2

60

SDG12S8●●●H30 [4]

SDW12S8●●●H30 [4]

SDA22S8●●●H30 [4]

SDA12S8●●●H30 [4]

230
(240)

 3

0

30

SBG12S8●●●H30 [4]

SBW12S8●●●H30 [4]

SBA22S8●●●H30 [4]

SBA12S8●●●H30 [4]

5

1

30

SCG12S8●●●H30 [4]

SCW12S8●●●H30 [4]

SCA22S8●●●H30 [4]

SCA12S8●●●H30 [4]

7-1/2

1

60

SCG13S8●●●H30 [4]

SCW13S8●●●H30 [4]

SCA23S8●●●H30 [4]

SCA13S8●●●H30 [4]

15

2

60

SDG12S8●●●H30 [4]

SDW12S8●●●H30 [4]

SDA22S8●●●H30 [4]

SDA12S8●●●H30 [4]

460
(480)

5

0

30

SBG13S8●●●H30 [4]

SBW13S8●●●H30 [4]

SBA23S8●●●H30 [4]

SBA13S8●●●H30 [4]

10

1

30

SCG14S8●●●H30 [4]

SCW14S8●●●H30 [4]

SCA24S8●●●H30 [4]

SCA14S8●●●H30 [4]

15

2

30

SDG16S8●●●H301

SDW16S8●●●H301

SDA26S8●●●H301

SDA16S8●●●H301

25

2

60

SDG14S8●●●H30 [4]

SDW14S8●●●H30 [4]

SDA24S8●●●H30 [4]

SDA14S8●●●H30 [4]

575
(600)

5

0

30

SBG13S8●●●H30 [4]

SBW13S8●●●H30 [4]

SBA23S8●●●H30 [4]

SBA13S8●●●H30 [4]

10

1

30

SCG14S8●●●H30 [4]

SCW14S8●●●H30 [4]

SCA24S8●●●H30 [4]

SCA14S8●●●H30 [4]

15

2

30

SDG16S8●●●H301

SDW16S8●●●H301

SDA26S8●●●H301

SDA16S8●●●H301

25

2

60

SDG14S8●●●H30 [4]

SDW14S8●●●H30 [4]

SDA24S8●●●H30 [4]

SDA14S8●●●H30 [4]

Class 8538 Fusible Disconnect Switch Type with Class R Fuse Clips—NEMA Size 0–2[12] [6]

200
(208)

3

0

30

SBG32S8●●●H30 [4]

SBW32S8●●●H30 [4]

SBA42S8●●●H30 [4]

SBA32S8●●●H30 [4]

5

1

30

SCG32S8●●●H30 [4]

SCW32S8●●●H30 [4]

SCA42S8●●●H30 [4]

SCA32S8●●●H30 [4]

7-1/2

1

60

SCG33S8●●●H30 [4]

SCW33S8●●●H30 [4]

SCA43S8●●●H30 [4]

SCA33S8●●●H30 [4]

10

2

60

SDG32S8●●●H30 [4]

SDW32S8●●●H30 [4]

SDA42S8●●●H30 [4]

SDA32S8●●●H30 [4]

230
(240)

3

0

30

SBG32S8●●●H30 [4]

SBW32S8●●●H30 [4]

SBA42S8●●●H30 [4]

SBA32S8●●●H30 [4]

5

1

30

SCG32S8●●●H30 [4]

SCW32S8●●●H30

SCA42S8●●●H30

SCA32S8●●●H30

7-1/2

1

60

SCG33S8●●●H30

SCW33S8●●●H30 [4]

SCA43S8●●●H30 [4]

SCA33S8●●●H30 [4]

15

2

60

SDG32S8●●●H30 [4]

SDW32S8●●●H30 [4]

SDA42S8●●●H30 [4]

SDA32S8●●●H30 [4]

460
(480)

5

0

30

SBG33S8●●●H30 [4]

SBW33S8●●●H30 [4]

SBA43S8●●●H30 [4]

SBA33S8●●●H30 [4]

10

1

30

SCG34S8●●●H30 [4]

SCW34S8●●●H30 [4]

SCA44S8●●●H30 [4]

SCA34S8●●●H30 [4]

15

2

30

SDG36S8●●●H301

SDW36S8●●●H301

SDA46S8●●●H301

SDA36S8●●●H301

25

2

60

SDG34S8●●●H30 [4]

SDW34S8●●●H30 [4]

SDA44S8●●●H30 [4]

SDA34S8●●●H30 [4]

575
(600)

5

0

30

SBG33S8●●●H30 [4]

SBW33S8●●●H30 [4]

SBA43S8●●●H30 [4]

SBA33S8●●●H30 [4]

10

1

30

SCG34S8●●●H30 [4]

SCW34S8●●●H30 [4]

SCA44S8●●●H30 [4]

SCA34S8●●●H30 [4]

15

2

30

SDG36S8●●●H301

SDW36S8●●●H301

SDA46S8●●●H301

SDA36S8●●●H301

25

2

60

SDG34S8●●●H30 [4]

SDW34S8●●●H30 [4]

SDA44S8●●●H30 [4]

SDA34S8●●●H30 [4]

note

Some control transformers may require the use of oversized enclosures. Refer to Control Transformer Selection

Coil Voltage Codes

Voltage

Code

60 Hz

50 Hz

  24[13]

120[14]

208

240

277

480

600

Specify

110

220

440

550

Specify

V01

V02

V08

V03

V04

V06

V07

V99

note

For voltage codes used with control transformers, see Selection of Control Circuit Transformers.

Class 8538 Fusible Disconnect Switch Type for Horizontal Mounting [6] (replace ●●● with the voltage code) [1]

Ratings

NEMA 12/3R [2] Dusttight and Driptight Industrial Use Enclosure

Motor Voltage
(Starter Voltage)

Max. Hp
Polyphase

NEMA
Size

Fuse Clip
Size (A)

With External Reset

Without External Reset

Type [9]

Type [9]

200 (208)

2

1

30

SCA22S1●●●H30

SCA12S1●●●H30

7-1/2

1

60

SCA23S1●●●H30

SCA13S1●●●H30

230 (240)

2

1

30

SCA22S1●●●H30

SCA12S1●●●H30

7-1/2

1

60

SCA23S1●●●H30

SCA13S1●●●H30

460 (480)

10

1

30

SCA24S1●●●H30

SCA14S1●●●H30

575 (600)

10

1

30

SCA24S1●●●H30

SCA14S1●●●H30

For How to Order Information, see Catalog Interpretation, Type S Starters.

Class 8539 / Refer to Catalog 8538CT9701

Electronic Motor Circuit Protector (MCP)

3-Pole Polyphase—600 Vac Maximum—50–60 Hz

For Form H30• (special lower-FLA factory-assembled starter combinations with Motor Logic SSOLR protection), see Solid-State Overload Relay Forms.

Class 8539 Full Voltage Type, Non-Reversing, 200–240 V, with Motor Logic SSOLR
(replace ●●● with the voltage code)
[1]

Ratings

NEMA 1
General Purpose Enclosure

NEMA 4X
Watertight and Dusttight Stainless Steel (304) Enclosure (Sizes 0–5)

NEMA 4X
Watertight, Dusttight, and Corrosion Resistant Polyester Enclosure

NEMA 12/3R[2]
Dusttight and Driptight
Industrial Use Enclosure

Motor Voltage
(Starter Voltage)

Hp
Range
Polyphase

NEMA
Size

Circuit Breaker
(See Page 7-32
for Breaker
Adjustment Range)

Type [9]

Type [9]

Type [9]

With
External
Reset

Without
External
Reset

Type [9]

Type [9]

200
(208)

0.25–3

0

HLL36030M71

SBG43●●●H30 [4]

SBW43●●●H30 [4]

SBW53●●●H30 [4]

SBA53●●●H30 [4]

SBA43●●●H30 [4]

0.25–5

7.5

1

HLL36030M71

HLL36050M72

SCG44●●●H30 [4]

SCG45●●●H30 [4]

SCW44●●●H30 [4]

SCW45●●●H30 [4]

SCW54●●●H30 [4]

SCW55●●●H30 [4]

SCA54●●●H30 [4]

SCA55●●●H30 [4]

SCA44●●●H30 [4]

SCA45●●●H30 [4]

1.5–5

7.5–10

2

HLL36030M71

HLL36050M72

SDG42●●●H301

SDG43●●●H30 [4]

SDW42●●●H301

SDW43●●●H30 [4]

SDW52●●●H301

SDW53●●●H30 [4]

SDA52●●●H301

SDA53●●●H30 [4]

SDA42●●●H301

SDA43●●●H30 [4]

15–25

3

HLL36100M73

SEG42●●●H30

SEW42●●●H30

SEW52●●●H30

SEA52●●●H30

SEA42●●●H30

30–40

4

JLL36250M75

SFG44●●●H30

SFW44●●●H30

SFW54●●●H30

SFA54●●●H30

SFA44●●●H30

50–60

75

5

JLL36250M75

LJL36400M36

SGG44●●●H30

SGG45●●●H30

SGW44●●●H30

SGW45●●●H30

SGA54●●●H30

SGA55●●●H30

SGA44●●●H30

SGA45●●●H30

100

125–150

6

LJL36400M36

LJL36600M42

SHG43●●●H30

SHG45●●●H30

SHA53●●●H30

SHA55●●●H30

SHA43●●●H30

SHA45●●●H30

230
(240)

0.25–3

0

HLL36030M71

SBG43●●●H30 [4]

SBW43●●●H30 [4]

SBW53●●●H30 [4]

SBA53●●●H30 [4]

SBA43●●●H30 [4]

0.25–7.5

1

HLL36030M71

SCG44●●●H30

[4]

SCW44●●●H30

[4]

SCW54●●●H30

[4]

SCA54●●●H30

[4]

SCA44●●●H30

[4]

1.5–7.5

10

15

2

HLL36030M71

HLL36050M72

HLL36100M73

SDG42●●●H301

SDG43●●●H30 [4]

SDG44●●●H30 [4]

SDW42●●●H301

SDW43●●●H30 [4]

SDW44●●●H30 [4]

SDW52●●●H301

SDW53●●●H30 [4]

SDW54●●●H30 [4]

SDA52●●●H301

SDA53●●●H30 [4]

SDA54●●●H30 [4]

SDA42●●●H301

SDA43●●●H30 [4]

SDA44●●●H30 [4]

15–30

3

HLL36100M73

SEG42●●●H30

SEW42●●●H30

SEW52●●●H30

SEA52●●●H30

SEA42●●●H30

40–50

4

JLL36250M75

SFG44●●●H30

SFW44●●●H30

SFW54●●●H30

SFA54●●●H30

SFA44●●●H30

60

75–100

5

JLL36250M75

LJL36400M36

SGG44●●●H30

SGG46●●●H30

SGW44●●●H30

SGW45●●●H30

SGA54●●●H30

SGA55●●●H30

SGA44●●●H30

SGA45●●●H30

125–150

200

6

LJL36600M42

PLL34080M68

SHG45●●●H30

SHG46●●●H30

SHA55●●●H30

SHA56●●●H30

SHA45●●●H30

SHA46●●●H30

Refer to page 16-31 for details.

NEMA Type 1 Enclosure

with 30 mm Operators

 

note

Some control transformers may require the use of oversized enclosures. Refer to Control Transformer Selection.

Coil Voltage Codes

Voltage

Code

60 Hz

50 Hz

  24[15]
120[16]
208
240

277
480
600
Specify


110

220


440
550
Specify

V01
V02
V08
V03

V04
V06
V07
V99

note

For voltage codes used with control transformers, see Selection of Control Circuit Transformers.
Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is available at no charge.

Dimensions: Approximate Dimensions
Factory Modifications (Forms): Full Voltage Starters
Replacement Parts (Class 9998): Magnetic Coils
Type S Accessories (Class 9999): Contact Kits

For How to Order Information, see Catalog Interpretation, Type S Starters.

For Form H30• (special lower-FLA factory-assembled starter combinations with Motor Logic SSOLR protection), see Solid-State Overload Relay Forms.

Class 8539 Full Voltage Type, Non-Reversing, 460–600 V, with Motor Logic SSOLR and Electronic Motor Circuit Protector (MCP) (replace ●●● with the voltage code) [1]

Ratings

NEMA 1
General Purpose
Enclosure

NEMA 4X
Watertight and Dusttight Enclosure, Stainless Steel (304) (Sizes 0–5)

NEMA 4X
Watertight, Dusttight, and Corrosion Resistant Polyester Enclosure

NEMA 12/3R[2]
Dusttight and Driptight Industrial Use Enclosure

Motor Voltage (Starter Voltage)

Hp Range Polyphase

NEMA
Size

Circuit Breaker (See Page 7-32 for Breaker Adjustment Range)

Type [9]

Type [9]

Type [9]

With
External Reset

Without
External Reset

Type [9]

Type [9]

460
(480)

0.25–5

0

HLL36030M71

SBG43●●●H30 [4]

SBW43●●●H30 [4]

SBW53●●●H30 [4]

SBA53●●●H30 [4]

SBA43●●●H30 [4]

0.25–10

1

HLL36030M71

SCG44●●●H30 [4]

SCW44●●●H30 [4]

SCW54●●●H30 [4]

SCA54●●●H30 [4]

SCA44●●●H30 [4]

5–15
20–25

2

HLL36030M71

HLL36050M72

SDG42●●●H301

SDG43●●●H30

SDW42●●●H301

SDW43●●●H30 [4]

SDW52●●●H301

SDW53●●●H30 [4]

SDA52●●●H301

SDA53●●●H30 [4]

SDA42●●●H301

SDA43●●●H30 [4]

20–25
30–50

3

HLL36050M72

HLL36100M73

SEG41●●●H30

SEG42●●●H30

SEW41●●●H30

SEW42●●●H30

SEW51●●●H30

SEW52●●●H30

SEA51●●●H30

SEA52●●●H30

SEA41●●●H30

SEA42●●●H30

60–100

4

JLL36250M75

SFG44●●●H30

SFW44●●●H30

SFW54●●●H30

SFA54●●●H30

SFA44●●●H30

125
150–200

5

JLL36250M75

LJL36400M36

SGG44●●●H30

SGG45●●●H30

SGW44●●●H30

SGW45●●●H30

SGA54●●●H30

SGA55●●●H30

SGA44●●●H30

SGA45●●●H30

250–350
400

6

LJL36600M42

PLL34080M68

SHG45●●●H30

SHG46●●●H30

SHA55●●●H30

SHA56●●●H30

SHA45●●●H30

SHA46●●●H30

575
(600)

0.25–5

0

HLL36030M71

SBG43●●●H30 [4]

SBW43●●●H30 [4]

SBW53●●●H30 [4]

SBA53●●●H30 [4]

SBA43●●●H30 [4]

0.25–10

1

HLL36030M71

SCG44●●●H30 [4]

SCW44●●●H30 [4]

SCW54●●●H30 [4]

SCA54●●●H30 [4]

SCA44●●●H30 [4]

5–20
25

2

HLL36030M71

HLL36050M72

SDG42●●●H301

SDG43●●●H30 [4]

SDW42●●●H301

SDW43●●●H30 [4]

SDW52●●●H301

SDW53●●●H30 [4]

SDA52●●●H301

SDA53●●●H30 [4]

SDA42●●●H301

SDA43●●●H30 [4]

25–30
40–50

3

HLL36050M72

HLL36100M73

SEG41●●●H30

SEG42●●●H30

SEW41●●●H30

SEW42●●●H30

SEW51●●●H30

SEW52●●●H30

SEA51●●●H30

SEA52●●●H30

SEA41●●●H30

SEA42●●●H30

 60–100

4

JLL36250M75

SFG44●●●H30

SFW44●●●H30

SFW54●●●H30

SFA54●●●H30

SFA44●●●H30

125–150
200

5

JLL36250M75

LJL36400M36

SGG44●●●H30

SGG45●●●H30

SGW44●●●H30

SGW45●●●H30

SGA54●●●H30

SGA55●●●H30

SGA44●●●H30

SGA45●●●H30

250
300–400

6

LJL36400M36

LJL36600M42

SHG43●●●H30

SHG45●●●H30

SHA53●●●H30

SHA55●●●H30

SHA43●●●H30

SHA45●●●H30

note

Some control transformers may require the use of oversized enclosures. Refer to Control Transformer Selection.

Coil Voltage Codes

Voltage

Code

60 Hz

50 Hz

  24[17]
120[18]
208
240

277
480
600
Specify


110

220


440
550
Specify

V01
V02
V08
V03

V04
V06
V07
V99

note

For voltage codes used with control transformers, see Selection of Control Circuit Transformers.
Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is available at no charge.

Dimensions: Approximate Dimensions
Factory Modifications (Forms): Full Voltage Starters
Replacement Parts (Class 9998): DP Starters
Type S Accessories (Class 9999): Contact Kits

For How to Order Information, see Catalog Interpretation, Type S Starters.

NEMA Size 0–2 in Oversized Enclosure

3-Pole Polyphase—600 Vac Maximum—50–60 Hz

For Form H30• (special lower-FLA factory-assembled starter combinations with Motor Logic™ SSOLR protection), see Solid-State Overload Relay Forms.

Class 8539 Electronic Motor Circuit Protectors (MCP) in Oversized Enclosure, NEMA Size 0–2 [1] [19] [20]
Full Voltage Type, Non-Reversing with Motor Logic SSOLR (replace ●●● with the voltage code)

Ratings

NEMA 1
General Purpose Enclosure

NEMA 4X
Watertight and Dusttight Stainless Steel (304) Enclosure

NEMA 12/3R[2]
Dusttight and Driptight
Industrial Use Enclosure

Motor Voltage (Starter Voltage)

Hp

Range Polyphase

NEMA
Size

Circuit Breaker (See Page 7-32 for Breaker Adjustment Range)

With
External Reset

Without
External Reset

Type [9]

Type [9]

Type [9]

Type [9]

200
(208)

0.25–3

0

HLL36030M71

SBG43S8●●●H30[4]

SBW43S8●●●H30[4]

SBA53S8●●●H30[4]

SBA43S8●●●H30[4]

0.25–5
7.5

1

HLL36030M71

HLL36050M72

SCG44S8●●●H30[4]

SCG45S8●●●H30[4]

SCW44S8●●●H30[4]

SCW45S8●●●H30[4]

SCA54S8●●●H30[4]

SCA55S8●●●H30[4]

SCA44S8●●●H30[4]

SCA45S8●●●H30[4]

1.5–5
7.5–10

2

HLL36030M71

HLL36050M72

SDG42S8●●●H301

SDG43S8●●●H30[4]

SDW42S8●●●H301

SDW43S8●●●H30[4]

SDA52S8●●●H301

SDA53S8●●●H30[4]

SDA42S8●●●H301

SDA43S8●●●H30[4]

230
(240)

0.25–3

0

HLL36030M71

SBG43S8●●●H30[4]

SBW43S8●●●H30[4]

SBA53S8●●●H30[4]

SBA43S8●●●H30[4]

0.25–7.5

1

HLL36030M71

SCG44S8●●●H30[4]

SCW44S8●●●H30[4]

SCA54S8●●●H30[4]

SCA44S8●●●H30[4]

1.5–7.5
10
15

2

HLL36030M71

HLL36050M72

HLL36100M73

SDG42S8●●●H301

SDG43S8●●●H30[4]

SDG44S8●●●H30[4]

SDW42S8●●●H301

SDW43S8●●●H30[4]

SDW44S8●●●H30[4]

SDA52S8●●●H301

SDA53S8●●●H30[4]

SDA54S8●●●H30[4]

SDA42S8●●●H301

SDA43S8●●●H30[4]

SDA44S8●●●H30[4]

460
(480)

0.25–5

0

HLL36030M71

SBG43S8●●●H30[4]

SBW43S8●●●H30[4]

SBA53S8●●●H30[4]

SBA43S8●●●H30[4]

0.25–10

1

HLL36030M71

SCG44S8●●●H30[4]

SCW44S8●●●H30[4]

SCA54S8●●●H30[4]

SCA44S8●●●H30[4]

5–15
20–25

2

HLL36030M71

HLL36050M72

SDG42S8●●●H301

SDG43S8●●●H30[4]

SDW42S8●●●H301

SDW43S8●●●H30[4]

SDA52S8●●●H301

SDA53S8●●●H30[4]

SDA42S8●●●H301

SDA43S8●●●H30[4]

575
(600)

0.25–5

0

HLL36060M71

SBG43S8●●●H30[4]

SBW43S8●●●H30[4]

SBA53S8●●●H30[4]

SBA43S8●●●H30[4]

0.25–10

1

HLL36030M71

SCG44S8●●●H30[4]

SCW44S8●●●H30[4]

SCA54S8●●●H30[4]

SCA44S8●●●H30[4]

5–20
25

2

HLL36030M71

HLL36050M72

SDG42S8●●●H301

SDG43S8●●●H30[4]

SDW42S8●●●H301

SDW43S8●●●H30[4]

SDA52S8●●●H301

SDA53S8●●●H30[4]

SDA42S8●●●H301

SDA43S8●●●H30[4]

note

Some control transformers may require the use of oversized enclosures. Refer to Control Transformer Selection.

Coil Voltage Codes

Voltage

Code

60 Hz

50 Hz

  24[21]
120[22]
208
240

277
480
600
Specify


110

220


440
550
Specify

V01
V02
V08
V03

V04
V06
V07
V99

note

For voltage codes used with control transformers, see Selection of Control Circuit Transformers.
Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is available at no charge.

Dimensions: Approximate Dimensions
Factory Modifications (Forms): Full Voltage Starters
Replacement Parts (Class 9998): Magnetic Coils
Type S Accessories (Class 9999): Contact Units for Melting Alloy Type Overload Relays

For How to Order Information, see Catalog Interpretation, Type S Starters.

Thermal Magnetic Circuit Breaker

Full Voltage Type

3-Pole Polyphase—600 Vac Maximum—50–60 Hz

For Form H30• (special lower-FLA factory-assembled starter combinations with Motor Logic SSOLR protection), see Solid-State Overload Relay Forms.

Class 8539 Full Voltage, Thermal-Magnetic Circuit Breaker Type, Non-Reversing, with Motor Logic SSOLR (replace ●●● with the voltage code) [1]

Ratings

NEMA 1
General Purpose
Enclosure

NEMA 4X
Watertight
and Dusttight
Enclosure
Stainless Steel (304)
(Sizes 0–5)

NEMA 4X
Watertight,
Dusttight and Corrosion Resistant
Polyester Enclosure

NEMA 12/3R[2]
Dusttight and Driptight
Industrial Use
Enclosure

Motor
Voltage
(Starter
Voltage)

Max. Hp
Polyphase

NEMA
Size

Circuit Breaker

Type [23]

Type [23]

Type [23]

With
External
Reset

Without
External
Reset

Type

Ampere
Rating

Type [23]

Type [23]

200
(208)

2
3

0

HLL36015


HLL36020

15
20

SBG1●●●H30 [4]

SBG3●●●H30 [4]

SBW1●●●H30 [4]

SBW3●●●H30 [4]

SBW11●●●H30 [4]

SBW13●●●H30 [4]

SBA11●●●H30 [4]

SBA13●●●H30 [4]

SBA1●●●H30 [4]

SBA3●●●H30 [4]

5
7-1/2

1

HLL36035
HLL36050

35
50

SCG5●●●H30 [4]

SCG2●●●H30 [4]

SCW5●●●H30 [4]

SCW2●●●H30 [4]

SCW15●●●H30 [4]

SCW12●●●H30 [4]

SCA15●●●H30 [4]

SCA12●●●H30 [4]

SCA5●●●H30 [4]

SCA2●●●H30 [4]

10

2

HLL36060

60

SDG1●●●H30 [4]