Water Traces
Isolation Trace
This trace makes use of Esri’s Isolation tracer.
We use the following parameters:
-
Retrieve the WaterDistributionTierName from the Water Domain configuration
-
Functions are set to an empty list
-
Do NOT Validate Consistency
-
Do NOT include barriers with results
-
Include isolated features
-
Barriers are set to Regulator and Isolating devices
Esri’s tracing methods generate an exception upon detecting dirty areas unless the Validate Consistency parameter is set to false. Given that trace results provide valuable troubleshooting insights beyond the identification of dirty areas, and given that Esri highlights dirty areas in various ways, we request trace results be returned even in the presence of dirty areas.
We do NOT include barriers in trace results in order to avoid getting abandoned features returned with trace results.
System Trace
This trace uses Esri’s Connected Trace.
We use the following parameters:
-
Retrieve the WaterDistributionTierName from the Water Domain configuration
-
Functions are set to an empty list
-
Target tier and Source tier are null
-
Do NOT Validate Consistency
-
Do NOT include barriers with results