DOCA0157EN-08

PowerTag Data Availability

Presentation

The data transmitted by the PowerTag Energy sensors to the PowerTag Link gateway depends on the type of PowerTag Energy sensors. The following tables indicate which data are available in the PowerTag Link gateway according to the type of PowerTag Energy sensors.

Device Commercial References

The device commercial references used for each type of PowerTag Energy sensors are:

  • A1: A9MEM1520, A9MEM1521, A9MEM1522, A9MEM1541, A9MEM1542

  • A2: A9MEM1540, A9MEM1543

  • P1: A9MEM1561, A9MEM1562, A9MEM1563, A9MEM1571, A9MEM1572

  • F1: A9MEM1560, A9MEM1570

  • F2: A9MEM1573

  • F3: A9MEM1564, A9MEM1574

  • FL: A9MEM1580

  • M0: LV434020

  • M1: LV434021

  • M2: LV434022

  • M3: LV434023

  • R1: A9MEM1590, A9MEM1591, A9MEM1592, A9MEM1593

Power

Data

PowerTag M63

PowerTag P63

PowerTag F63

PowerTag F160

PowerTag M250

PowerTag M630

PowerTag Rope

A1

A2

P1

F1

F2

F3

FL

M0

M1

M2

M3

R1

Total active power

Per phase active power

NA(1)

NA(1)

(2)

(2)

(2)

(2)

Total reactive power

Per phase reactive power

(2)

(2)

Total apparent power

Per phase apparent power

(2)

(2)

Total factor power

Per phase factor power

(2)

(2)

Actual demand power

Peak demand power

(1) Not applicable because there is no neutral voltage on the PowerTag Energy sensors.

(2) The values are significant only if the neutral voltage picking is connected.

Energy

Data

PowerTag M63

PowerTag P63

PowerTag F63

PowerTag F160

PowerTag M250

PowerTag M630

PowerTag Rope

A1

A2

P1

F1

F2

F3

FL

M0

M1

M2

M3

R1

Total resettable active energy delivered

Total non resettable active energy delivered

Per phase resettable active energy delivered

(2)

(2)

Per phase non resettable active energy delivered

(2)

(2)

Total resettable active energy received

Total non resettable active energy received

Per phase resettable active energy received

(2)

(2)

Per phase non resettable active energy received

(2)

(2)

Total resettable active energy delivered and received

Total non resettable active energy delivered and received

Per phase resettable active energy delivered and received

NA(1)

NA(1)

Per phase non resettable active energy delivered and received

NA(1)

(2)

(2)

NA(1)

Total resettable reactive energy delivered

Total non resettable reactive energy delivered

(2)

(2)

Per phase resettable reactive energy delivered

(2)

(2)

Per phase non resettable reactive energy delivered

Total resettable reactive energy received

Total non resettable reactive energy received

(2)

(2)

Per phase resettable reactive energy received

(2)

(2)

Per phase non resettable reactive energy received

(2)

(2)

Total resettable apparent energy delivered and received

Total non resettable apparent energy delivered and received

Per phase resettable apparent energy delivered and received

(2)

(2)

Per phase non resettable apparent energy delivered and received

(2)

(2)

(1) Not applicable because energy is individually cumulated in received and delivered counters.

(2) The values are significant only if the neutral voltage picking is connected.

Alarms

Data

PowerTag M63

PowerTag P63

PowerTag F63

PowerTag F160

PowerTag M250

PowerTag M630

PowerTag Rope

A1

A2

P1

F1

F2

F3

FL

M0

M1

M2

M3

R1

Voltage loss

Overcurrent at voltage loss

Load current 45%

Load current loss

Over oltage 120%

Undervoltage 80%

RMS current on phase A, B, C at voltage loss

Other Measurements

Data

PowerTag M63

PowerTag P63

PowerTag F63

PowerTag F160

PowerTag M250

PowerTag M630

PowerTag Rope

A1

A2

P1

F1

F2

F3

FL

M0

M1

M2

M3

R1

Phase current (measured)

Neutral current (calculated)

Phase-to-phase voltage

Phase-to-neutral voltage

NA(1)

NA(1)

(2)

(2)

(2)

(2)

Frequency

Quadrant

1

1

1

1

1

1

4

4

4

4

4

4

Internal temperature

Load operating time counter

(1) Not applicable because there is no neutral voltage on the PowerTag Energy sensors.

(2) The values are significant only if the neutral voltage picking is connected.

QR Code is a registered trademark of DENSO WAVE INCORPORATED in Japan and other countries.

Was this helpful?