Electrical Metering
Demand Data
Address |
Register |
No. |
RW |
X |
Unit |
Type |
Range |
Invalid Value |
Svd |
Function Code |
Applicable Devices |
Description |
---|---|---|---|---|---|---|---|---|---|---|---|---|
0x1770 |
6001 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/R |
Demand total active power of the 1st device |
0x1772 |
6003 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/R |
Demand total active power of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x1836 |
6199 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/R |
Demand total active power of the 100th device |
0x1838 |
6201 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
Y |
03, 100–4 |
A/R |
Maximum Demand total active power of the 1st device |
0x183A |
6203 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
Y |
03, 100–4 |
A/R |
Maximum Demand total active power of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x18FE |
6399 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
Y |
03, 100–4 |
A/R |
Maximum Demand total active power of the 100th device |
0x1900 |
6401 |
4 |
R |
NA |
NA |
D/T IEC 870-5-4 (T081) |
NA |
0x0000000000000000 |
Y |
03, 100–4 |
A/R |
Maximum Demand total active power Time stamp of the 1st device |
0x1902 |
6405 |
4 |
R |
NA |
NA |
D/T IEC 870-5-4 (T081) |
NA |
0x0000000000000000 |
Y |
03, 100–4 |
A/R |
Maximum Demand total active power Time stamp of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x1A8C |
6797 |
4 |
R |
NA |
NA |
D/T IEC 870-5-4 (T081) |
NA |
0x0000000000000000 |
Y |
03, 100–4 |
A/R |
Maximum Demand total active power Time stamp of the 100th device |
Current Metering Data
Address |
Register |
No. |
RW |
X |
Unit |
Type |
Range |
Invalid Value |
Svd |
Function Code |
Applicable Devices |
Description |
---|---|---|---|---|---|---|---|---|---|---|---|---|
0x1A90 |
6801 |
2 |
R |
NA |
A |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS current on phase A of the 1st device |
0x1A92 |
6803 |
2 |
R |
NA |
A |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS current on phase A of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x1B56 |
6999 |
2 |
R |
NA |
A |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS current on phase A of the 100th device |
0x1B58 |
7001 |
2 |
R |
NA |
A |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS current on phase B of the 1st device |
0x1B5A |
7003 |
2 |
R |
NA |
A |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS current on phase B of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x1C1E |
7199 |
2 |
R |
NA |
A |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS current on phase B of the 100th device |
0x1C20 |
7201 |
2 |
R |
NA |
A |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS current on phase C of the 1st device |
0x1C22 |
7203 |
2 |
R |
NA |
A |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS current on phase C of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x1CE6 |
7399 |
2 |
R |
NA |
A |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS current on phase C of the 100th device |
0x1CE8 |
7401 |
2 |
R |
NA |
A |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
R |
RMS current on Neutral of the 1st device (calculated) |
0x1CEA |
7403 |
2 |
R |
NA |
A |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
R |
RMS current on Neutral of the 2nd device (calculated) |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x1DAE |
7599 |
2 |
R |
NA |
A |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
R |
RMS current on Neutral of the 100th device (calculated) |
0x1DB0 |
7601 |
2 |
R |
NA |
A |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS average current of the 1st device |
0x1DB2 |
7603 |
2 |
R |
NA |
A |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS average current of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x1E76 |
7799 |
2 |
R |
NA |
A |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS average current of the 100th device |
Voltage Metering Data
Address |
Register |
No. |
RW |
X |
Unit |
Type |
Range |
Invalid Value |
Svd |
Function Code |
Applicable Devices |
Description |
---|---|---|---|---|---|---|---|---|---|---|---|---|
0x1E78 |
7801 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS phase-to-phase voltage A-B of the 1st device |
0x1E7A |
7803 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS phase-to-phase voltage A-B of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x1F3E |
7999 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS phase-to-phase voltage A-B of the 100th device |
0x1F40 |
8001 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS phase-to-phase voltage B-C of the 1st device |
0x1F42 |
8003 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS phase-to-phase voltage B-C of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x2006 |
8199 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS phase-to-phase voltage B-C of the 100th device |
0x2008 |
8201 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS phase-to-phase voltage C-A of the 1st device |
0x200A |
8203 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS phase-to-phase voltage C-A of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x20CE |
8399 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS phase-to-phase voltage C-A of the 100th device |
0x20D0 |
8401 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Average phase-to-phase voltage of the 1st device |
0x20D2 |
8403 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Average phase-to-phase voltage of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x2196 |
8599 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Average phase-to-phase voltage of the 100th device |
0x2198 |
8601 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS phase-to-neutral voltage A-N of the 1st device |
0x219A |
8603 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS phase-to-neutral voltage A-N of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x225E |
8799 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS phase-to-neutral voltage A-N of the 100th device |
0x2260 |
8801 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS phase-to-neutral voltage B-N of the 1st device |
0x2262 |
8803 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS phase-to-neutral voltage B-N of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x2326 |
8999 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS phase-to-neutral voltage B-N of the 100th device |
0x2328 |
9001 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS phase-to-neutral voltage C-N of the 1st device |
0x232A |
9003 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS phase-to-neutral voltage C-N of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x23EE |
9199 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
RMS phase-to-neutral voltage C-N of the 100th device |
0x23F0 |
9201 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Average phase-to-neutral voltage of the 1st device |
0x23F2 |
9203 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Average phase-to-neutral voltage of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x24B6 |
9399 |
2 |
R |
NA |
V |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Average phase-to-neutral voltage of the 100th device |
Power Metering Data
Address |
Register |
No. |
RW |
X |
Unit |
Type |
Range |
Invalid Value |
Svd |
Function Code |
Applicable Devices |
Description |
---|---|---|---|---|---|---|---|---|---|---|---|---|
0x24B8 |
9401 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Active power on phase A of the 1st device |
0x24BA |
9403 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Active power on phase A of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x257E |
9599 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Active power on phase A of the 100th device |
0x2580 |
9601 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Active power on phase B of the 1st device |
0x2582 |
9603 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Active power on phase B of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x2646 |
9799 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Active power on phase B of the 100th device |
0x2648 |
9801 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Active power on phase C of the 1st device |
0x264A |
9803 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Active power on phase C of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x270E |
9999 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Active power on phase C of the 100th device |
0x2710 |
10001 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Total active power of the 1st device |
0x2712 |
10003 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Total active power of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x27D6 |
10199 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Total active power of the 100th device |
0x27D8 |
10201 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
M/R |
Total reactive power of the 1st device |
0x27DA |
10203 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
M/R |
Total reactive power of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x289E |
10399 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
M/R |
Total reactive power of the 100th device |
0x28A0 |
10401 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
R |
Total apparent power of the 1st device |
0x28A2 |
10403 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
R |
Total apparent power of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x2966 |
10599 |
2 |
R |
NA |
W |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
R |
Total apparent power of the 100th device |
Power Factor Metering Data
Address |
Register |
No. |
RW |
X |
Unit |
Type |
Range |
Invalid Value |
Svd |
Function Code |
Applicable Devices |
Description |
---|---|---|---|---|---|---|---|---|---|---|---|---|
0x2968 |
10601 |
2 |
R |
NA |
NA |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Total power factor of the 1st device |
0x296A |
10603 |
2 |
R |
NA |
NA |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Total power factor of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x2A2E |
10799 |
2 |
R |
NA |
NA |
Float32 |
NA |
0xFFC00000 |
N |
03, 100–4 |
A/M/R |
Total power factor of the 100th device |
Energy Metering Data
Address |
Register |
No. |
RW |
X |
Unit |
Type |
Range |
Invalid Value |
Svd |
Function Code |
Applicable Devices |
Description |
---|---|---|---|---|---|---|---|---|---|---|---|---|
0x2A30 |
10801 |
2 |
R |
NA |
kWh |
INT32 |
NA |
0x80000000 |
Y |
03, 100–4 |
A/M/R |
Total active energy delivered + received (not resettable) of the 1st device |
0x2A32 |
10803 |
2 |
R |
NA |
kWh |
INT32 |
NA |
0x80000000 |
Y |
03, 100–4 |
A/M/R |
Total active energy delivered + received (not resettable) of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x2AF6 |
10999 |
2 |
R |
NA |
kWh |
INT32 |
NA |
0x80000000 |
Y |
03, 100–4 |
A/M/R |
Total active energy delivered + received (not resettable) of the 100th device |
0x2AF8 |
11001 |
2 |
R |
NA |
kWh |
INT32 |
NA |
0x80000000 |
Y |
03, 100–4 |
A/M/R |
Partial active energy delivered + received of the 1st device |
0x2AFA |
11003 |
2 |
R |
NA |
kWh |
INT32 |
NA |
0x80000000 |
Y |
03, 100–4 |
A/M/R |
Partial active energy delivered + received of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x2BBE |
11199 |
2 |
R |
NA |
kWh |
INT32 |
NA |
0x80000000 |
Y |
03, 100–4 |
A/M/R |
Partial active energy delivered + received of the 100th device |
0x2BC0 |
11201 |
2 |
R |
NA |
kWh |
INT32 |
NA |
0x80000000 |
Y |
03, 100–4 |
A/M/R |
Total active energy delivered (not resettable) of the 1st device |
0x2BC2 |
11203 |
2 |
R |
NA |
kWh |
INT32 |
NA |
0x80000000 |
Y |
03, 100–4 |
A/M/R |
Total active energy delivered (not resettable) of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x2C86 |
11399 |
2 |
R |
NA |
kWh |
INT32 |
NA |
0x80000000 |
Y |
03, 100–4 |
A/M/R |
Total active energy delivered (not resettable) of the 100th device |
0x2C88 |
11401 |
2 |
R |
NA |
kWh |
INT32 |
NA |
0x80000000 |
Y |
03, 100–4 |
A/M/R |
Total active energy received (not resettable) of the 1st device |
0x2C8A |
11403 |
2 |
R |
NA |
kWh |
INT32 |
NA |
0x80000000 |
Y |
03, 100–4 |
A/M/R |
Total active energy received (not resettable) of the 2nd device |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
... |
0x2D4E |
11599 |
2 |
R |
NA |
kWh |
INT32 |
NA |
0x80000000 |
Y |
03, 100–4 |
A/M/R |
Total active energy received (not resettable) of the 100th device |