Selecting Thermal Units
Thermal Unit Selection
Controller |
Thermal Unit Selection Table Number |
||||||
---|---|---|---|---|---|---|---|
Hand Reset Melting Alloy |
|||||||
Starter Type |
Class |
Type |
Series* |
Size |
Standard Trip |
Quick Trip |
Slow Trip |
Manual |
2510 |
F |
A |
FHP |
— |
— |
|
Manual
Starters |
2510 |
M, T |
A |
M–0 |
|||
M–1 |
|||||||
M–1P |
|||||||
Manual |
2510 |
M, T |
A |
M–0 |
|||
DC EC & M Crane Control Product |
7135 |
C, D |
— |
1, 2 |
— |
||
E |
— |
3 |
— |
— |
|||
F |
— |
4 |
— |
— |
|||
G |
— |
5 |
— |
— |
|||
AC |
8536 8933 I-LINE™ and QMB |
A |
B, C |
00 |
— |
— |
|
SA |
A, B |
00 |
— |
||||
SB |
A |
0 |
|||||
SC |
A |
1 |
|||||
A |
1P |
— |
|||||
SD |
A |
2 |
|||||
SE |
A |
3 |
|||||
SF |
A |
4 |
— |
— |
|||
SG |
A |
5 |
— |
— |
|||
B* |
5 |
— |
|||||
SH |
A, B |
6 |
— |
— |
|||
AC |
8998 |
SC |
A |
1 Fusible |
— |
||
1 Circuit Breaker |
— |
||||||
SD |
A |
2 Fusible |
— |
||||
2 Circuit Breaker |
— |
||||||
SE |
A |
3 Small Enclosure |
|||||
3 Large Enclosure |
|||||||
SF |
A |
4 |
— |
— |
|||
SG |
A |
5 |
— |
— |
|||
SH |
A |
6 |
— |
— |
|||
AC |
8998 |
SC* |
A |
1 |
— |
— |
|
1 COMPAC 6 |
— |
— |
|||||
SD * |
A |
2 |
— |
— |
|||
SE* |
A |
3 |
— |
— |
|||
SF* |
A |
4 |
— |
— |
|||
SG* |
A |
5 |
— |
— |
|||
B |
5 CT |
— |
— |
||||
SH * |
A |
6 |
— |
— |
|||
8911 |
DPSG |
C |
20–30 A |
— |
— |
||
40 A |
— |
— |
|||||
A |
50 A |
— |
— |
||||
AC |
8198 |
G, S |
— |
— |
— |
* | |
8536 (Starter Used in 8538, 8904* 8539, 8906 8606, 8907 8630*, 8920 8640*, 8922 9089, 8924 8647, 8925 8650, 8930 8736, 8738, |
A (8536 only) |
B, C |
00 |
— |
— |
||
SA |
A, B |
00 |
— |
* | |||
SB, NB |
A |
0 |
* | ||||
SC, NC |
A |
1 |
* | ||||
SD, ND |
A |
2 |
* | ||||
SE, NE |
A |
3 |
|||||
SF, NF |
A |
4 |
— |
— |
|||
SG |
A |
5 |
— |
— |
|||
B* |
5 |
— |
|||||
SH |
A, B |
6 |
— |
||||
AC |
8810, 8811 |
CB, DB, SB, UB |
A |
0 |
|||
CC, DC, SC, UC |
A |
1 |
|||||
CD, DD, SD, UD |
A |
2 |
|||||
CE, DE, SE, UE |
A |
3 |
|||||
CF, DF, SF, UF |
A |
4 |
— |
— |
|||
CG, DG, SG, UG |
A |
5 |
— |
— |
|||
B* |
5 |
— |
|||||
CH, DH, SH, UH |
A |
6 |
— |
||||
8940 WELL-GUARD™ |
WC, XC |
A |
1 |
— |
|||
WD, XD, MD, RD, VD |
A |
2 |
— |
||||
WE, XE, ME, RE, VE |
A |
3 |
— |
||||
PF, WF, XF, MF, RF, VF, PE |
A |
4 |
— |
— |
|||
8911 |
DPSO |
C |
20–30 A |
— |
— |
||
40 A |
— |
— |
|||||
A |
50 A |
— |
— |
||||
AC |
8998 |
SC* |
A |
1 |
— |
— |
|
SD* |
A |
2 |
— |
— |
|||
SE* |
A |
3 |
— |
— |
|||
SF |
A |
4 |
— |
— |
|||
SG |
A |
5 |
— |
— |
|||
B* |
5 CT |
— |
— |
||||
Separately Mounted Overload Relays |
9065 |
C |
A |
1 (25 A) |
|||
F |
B |
4 (133 A) |
— |
— |
|||
G |
A |
5 (266 A) |
— |
— |
|||
MEO |
A |
(32 A) |
— |
— |
|||
S |
A |
1 (26 A) |
|||||
2 (45 A) |
|||||||
3 (86 A) |
— |
— |
|||||
4 (133 A) |
— |
— |
|||||
T |
A |
2 (45 A) |
— |
||||
U |
— |
3 (86 A) |
— |
— |