3rd telegram information
|
Byte No |
Size |
Value |
Description |
|---|---|---|---|
|
1 |
1 |
68 |
Start character |
|
2 |
1 |
F1 |
L-field, calculated from C field to last user data |
|
3 |
1 |
F1 |
L-field, repeated |
|
4 |
1 |
68 |
Start character |
|
5 |
1 |
08 |
C-field, RSP_UD |
|
6 |
1 |
X |
A-field, address |
|
7 |
1 |
72 |
CI-field, variable data respond, LSB first |
|
8 – 11 |
4 |
XXXX |
Identification Number, 8 BCD digits |
|
12 – 13 |
2 |
4CA3 |
Manufacturer: SCH |
|
14 |
1 |
00 |
Version |
|
15 |
1 |
02 |
Medium, 02 = Electricity |
|
16 |
1 |
X |
Number of accesses |
|
17 |
1 |
00 |
Status |
|
18 – 19 |
2 |
0000 |
Signature (0000 = no encryption) |
|
20 |
1 |
02 |
DIF size, 16 Bit Integer |
|
21 |
1 |
FF |
VIF next byte is manufacturer specific |
|
22 |
1 |
34 |
Overload alarm setup |
|
23 – 24 |
2 |
XX |
Value, Overload alarm setup |
|
25 |
1 |
05 |
DIF size, 32 Bit Real |
|
26 |
1 |
FF |
VIF next byte is manufacturer specific |
|
27 |
1 |
FF |
Pickup setpoint |
|
28 – 31 |
4 |
35 |
Value, Pickup setpoint |
|
32 |
1 |
XXXX |
DIF size, 16 Bit Integer |
|
33 |
1 |
02 |
VIF next byte is manufacturer specific |
|
34 |
1 |
FF |
Digital output associate |
|
35 – 36 |
2 |
36 |
Value, Digital output associate |
|
37 |
1 |
XX |
DIF size, 16 Bit Integer |
|
38 |
1 |
02 |
VIF next byte is manufacturer specific |
|
39 |
1 |
FF |
Activated status |
|
40 – 41 |
2 |
37 |
Value, Activated status |
|
42 |
1 |
XX |
DIF size, 16 Bit Integer |
|
43 |
1 |
02 |
VIF next byte is manufacturer specific |
|
44 |
1 |
FF |
Unacknowledged status |
|
45 – 46 |
2 |
38 |
Value, Unacknowledged status |
|
47 |
1 |
XX |
DIF size, 32 Bit Integer |
|
48 |
1 |
04 |
Date/Time |
|
49 |
1 |
ED |
VIF next byte is manufacturer specific |
|
50 |
1 |
FF |
Date time last alarm |
|
51 – 54 |
4 |
39 |
Value, Date time last alarm |
|
55 |
1 |
XXXX |
DIF size, 32 Bit Real |
|
56 |
1 |
05 |
VIF next byte is manufacturer specific |
|
57 |
1 |
FF |
Value last alarm |
|
58 – 61 |
4 |
3A |
Value last alarm |
|
62 |
1 |
XXXX |
DIF size, 48 Bit Integer |
|
63 |
1 |
06 |
VIF next byte is manufacturer specific |
|
64 |
1 |
FF |
Meter operation time |
|
65 – 70 |
6 |
20 |
Value, Meter operation time |
|
71 |
1 |
XXXXXX |
DIF size, 24 Bit Integer |
|
72 |
1 |
03 |
VIF next byte is manufacturer specific |
|
73 |
1 |
FF |
Num of phases |
|
74 – 76 |
3 |
21 |
Value, Num of phases |
|
77 |
1 |
XXX |
DIF size, 24 Bit Integer |
|
78 |
1 |
03 |
VIF next byte is manufacturer specific |
|
79 |
1 |
FF |
Num of wires |
|
80 – 82 |
3 |
22 |
Value, Num of wires |
|
83 |
1 |
XXX |
DIF size, 24 Bit Integer |
|
84 |
1 |
03 |
VIF next byte is manufacturer specific |
|
85 |
1 |
FF |
Power System Configuration |
|
86 – 88 |
3 |
23 |
Value, Power System Configuration |
|
89 |
1 |
XXX |
DIF size, 24 Bit Integer |
|
90 |
1 |
03 |
VIF next byte is manufacturer specific |
|
91 |
1 |
FF |
Nominal Frequency |
|
92 – 94 |
3 |
24 |
Value, Nominal Frequency |
|
95 |
1 |
05 |
DIF size, 32 Bit Real |
|
96 |
1 |
03 |
Energy |
|
97 – 100 |
4 |
XXXX |
Total Active Energy Import |
|
101 |
1 |
05 |
DIF size, 32 Bit Real |
|
102 |
1 |
83 |
Energy |
|
103 |
1 |
FF |
VIF next byte is manufacturer specific |
|
104 |
1 |
09 |
Export energy |
|
105 – 108 |
4 |
XXXX |
Total Active Energy Export |
|
109 |
1 |
85 |
DIF size, 32 Bit Real |
|
110 |
1 |
40 |
DIFE: Unit1 |
|
111 |
1 |
03 |
Energy |
|
112 – 115 |
4 |
XXXX |
Total Reactive Energy Import |
|
116 |
1 |
85 |
DIF size, 32 Bit Real |
|
117 |
1 |
40 |
DIFE:Unit 1 |
|
118 |
1 |
83 |
Energy |
|
119 |
1 |
FF |
VIF next byte is manufacturer specific |
|
120 |
1 |
09 |
Export energy |
|
121 – 124 |
4 |
XXXX |
Total Reactive Energy Export |
|
125 |
1 |
05 |
DIF size, 32 Bit Real |
|
126 |
1 |
83 |
Energy |
|
127 |
1 |
FF |
VIF next byte is manufacturer specific |
|
128 |
1 |
0D |
Partial energy |
|
129 – 132 |
4 |
XXXX |
Partial Active Energy Import |
|
133 |
1 |
85 |
DIF size, 32 Bit Real |
|
134 |
1 |
40 |
DIFE: Unit 1 |
|
135 |
1 |
83 |
Energy |
|
136 |
1 |
FF |
VIF next byte is manufacturer specific |
|
137 |
1 |
0D |
Partial Energy |
|
138 – 141 |
4 |
XXXX |
Partial Reactive Energy Import |
|
142 |
1 |
05 |
DIF size, 32 Bit Real |
|
143 |
1 |
83 |
Energy |
|
144 |
1 |
FF |
VIF next byte is manufacturer specific |
|
145 |
1 |
01 |
L1 |
|
146 – 149 |
4 |
XXXX |
Active Energy Delivered, L1 |
|
150 |
1 |
05 |
DIF size, 32 Bit Real |
|
151 |
1 |
83 |
Energy |
|
152 |
1 |
FF |
VIF next byte is manufacturer specific |
|
153 |
1 |
02 |
L2 |
|
154 – 157 |
4 |
XXXX |
Active Energy Delivered, L2 |
|
158 |
1 |
05 |
DIF size, 32 Bit Real |
|
159 |
1 |
83 |
Energy |
|
160 |
1 |
FF |
VIF next byte is manufacturer specific |
|
161 |
1 |
03 |
L3 |
|
162 – 165 |
4 |
XXXX |
Active Energy Delivered, L3 |
|
166 |
1 |
05 |
DIF size, 32 Bit Real |
|
167 |
1 |
FD |
VIF extension |
|
168 |
1 |
61 |
Input Metering Accumulation Channel 1 |
|
169 – 172 |
4 |
XXXX |
Input Metering Channel 1 Value |
|
173 |
1 |
85 |
DIF size, 32 Bit Real |
|
174 |
1 |
10 |
DIFE: Tariff 1 |
|
175 |
1 |
03 |
Energy |
|
176 – 179 |
4 |
XXXX |
Active Energy Delivered Rate 1 |
|
180 |
1 |
85 |
DIF size, 32 Bit Real |
|
181 |
1 |
20 |
DIFE: Tariff 2 |
|
182 |
1 |
03 |
Energy |
|
183 – 186 |
4 |
XXXX |
Active Energy Delivered Rate 2 |
|
187 |
1 |
85 |
DIF size, 32 Bit Real |
|
188 |
1 |
30 |
DIFE: Tariff 3 |
|
189 |
1 |
03 |
Energy |
|
190 – 193 |
4 |
XXXX |
Active Energy Delivered Rate 3 |
|
194 |
1 |
85 |
DIF size, 32 Bit Real |
|
195 |
1 |
80 |
DIFE: Tariff 4 |
|
196 |
1 |
10 |
DIFE: Tariff 4 |
|
197 |
1 |
03 |
Energy |
|
198 – 201 |
4 |
XXXX |
Active Energy Delivered Rate 4 |
|
202 |
1 |
03 |
DIF size, 24 Bit Integer |
|
203 |
1 |
FF |
VIF next byte is manufacturer specific |
|
204 |
1 |
25 |
Number VTs |
|
205 – 207 |
3 |
XXX |
Value, Number VTs |
|
208 |
1 |
05 |
DIF size, 32 Bit Real |
|
209 |
1 |
FF |
VIF next byte is manufacturer specific |
|
210 |
1 |
26 |
VT Primary |
|
211 – 214 |
4 |
XXXX |
Value, VT Primary |
|
215 |
1 |
03 |
DIF size, 24 Bit Integer |
|
216 |
1 |
FF |
VIF next byte is manufacturer specific |
|
217 |
1 |
27 |
VT Secondary |
|
218 – 220 |
3 |
XXX |
Value, VT Secondary |
|
221 |
1 |
03 |
DIF size, 24 Bit Integer |
|
222 |
1 |
FF |
VIF next byte is manufacturer specific |
|
223 |
1 |
28 |
Number CTs |
|
224 – 226 |
3 |
XXX |
Value, Number CTs |
|
227 |
1 |
03 |
DIF size, 24 Bit Integer |
|
228 |
1 |
FF |
VIF next byte is manufacturer specific |
|
229 |
1 |
29 |
CT Primary |
|
230 – 232 |
3 |
XXX |
Value, CT Primary |
|
233 |
1 |
03 |
DIF size, 24 Bit Integer |
|
234 |
1 |
FF |
VIF next byte is manufacturer specific |
|
235 |
1 |
2A |
CT Secondary |
|
236 – 238 |
3 |
XXX |
Value, CT Secondary |
|
239 |
1 |
03 |
DIF size, 24 Bit Integer |
|
240 |
1 |
FF |
VIF next byte is manufacturer specific |
|
241 |
1 |
2B |
VT connection type |
|
242 – 244 |
3 |
XXX |
Value, VT connection type |
|
245 |
1 |
0F |
DIF indicating that this is the last telegram |
|
246 |
1 |
X |
CS checksum, calculated from C field to last data |
|
247 |
1 |
16 |
Stop character |