Overview of meter features
The PM5500 / PM5600 / PM5700 complies to Class 0.2S accuracy standards and feature high quality, reliability and affordability in a compact and easy to install format.
Hardware
- 
                     A fourth current input for direct and accurate measurement of neutral current, to help avoid device overload and network outage. 
- 
                     Two digital outputs for control and energy pulsing applications. 
- 
                     Four digital inputs/two digital inputs with input metering support for WAGES monitoring applications. 
- 
                     LED that can be used for energy pulsing applications. 
Applicable for specific meter models:
- 
                     Two Residual Current Measurement (RCM) inputs. 
- 
                     Two analog inputs to interpret an incoming analog current signal from transducers and provide the resulting scaled value. 
- 
                     Low-voltage DC control power. 
Display and user interface
- 
                     Onboard webpages for displaying real-time, logged data and waveform capture information using a web browser. 
- 
                     Multiple language support: The back-lit anti-glare display screen can be switched to display meter information in one of the supported languages (on models with a display screen). 
- 
                     Graphical display of harmonics and phasor diagrams on models with an integrated or optional remote display. 
- 
                     QR codes with embedded data for viewing meter information using Meter Insights. 
Alarming
- 
                     Extensive alarming options like unary, digital, standard, logic, custom, and disturbance alarms. 
- 
                     The ability to send emails with alarm information. 
Communications
- 
                     Dual Ethernet switched ports allow fast Ethernet interconnection to other PM5500 / PM5600 / PM5700 meters using only one IP switch. 
- 
                     Ethernet gateway functionality, allowing a Modbus master using Modbus TCP to communicate through the meter to downstream serial devices using Modbus RTU. 
- 
                     Support for a variety of Ethernet protocols, such as Modbus TCP, BACnet/IP, EtherNet/IP and DNP3. All the Ethernet protocols can be used at the same time. 
- 
                     Enhanced Modbus security using TCP/IP filtering to set the specific IP addresses that are permitted to access the meter. 
Measurements and logging
- 
                     4-quadrant, Class 0.2S accurate energy metering. 
- 
                     Present, last, predicted and peak (maximum) demand using a selection of demand calculation methods. 
- 
                     Highly accurate 1-second measurements. 
- 
                     Onboard data logging support for up to 14 selectable parameters. 
- 
                     Complete harmonic distortion metering, recording and realtime reporting, up to the 63rd harmonic for all voltage and current inputs. 
- 
                     Recording of each new minimum and new maximum value. 
Revenue and tariffs
- 
                     Multiple tariff support (8 tariffs) for monitoring energy usage. 
- 
                     Models with features to help you comply with revenue and billing standards. 
Compliance to international standards
- 
                     IEC 62053-22: 2020, BS/ EN 62053-22 Class 0.5S / Class 0.2S 
- 
                     ANSI C12.20 Class 0.2 
- 
                     IEC 61557-12: 2021, BS/ EN 61557-12 PMD/S/K70/0.2 
- 
                     IEC 62053-23: 2020, BS/ EN 62053-23 
- 
                     IEC 62052-11: 2020, BS/ EN 62052-11 
- 
                     IEC 62052-31: 2015, BS/ EN 62052-31 
- 
                     MID/MIR, BS/ EN 50470-1; BS/ EN 50470-3 – Annex B and Annex D 
- 
                     CE and cULus as per BS/ EN/ IEC/ UL 61010-1: 2010 + A1: 2019 
- 
                     BACnet/IP - BTL listed (B-ASC) 
- 
                     EtherNet/IP - ODVA certified