Overview of meter features
The PM5500 / PM5600 / PM5700 complies to Class 0.2S accuracy standards and feature high quality, reliability and affordability in a compact and easy to install format.
Hardware
-
A fourth current input for direct and accurate measurement of neutral current, to help avoid device overload and network outage.
-
Two digital outputs for control and energy pulsing applications.
-
Four digital inputs/two digital inputs with input metering support for WAGES monitoring applications.
-
LED that can be used for energy pulsing applications.
Applicable for specific meter models:
-
Two Residual Current Measurement (RCM) inputs.
-
Two analog inputs to interpret an incoming analog current signal from transducers and provide the resulting scaled value.
-
Low-voltage DC control power.
Display and user interface
-
Onboard webpages for displaying real-time, logged data and waveform capture information using a web browser.
-
Multiple language support: The back-lit anti-glare display screen can be switched to display meter information in one of the supported languages (on models with a display screen).
-
Graphical display of harmonics and phasor diagrams on models with an integrated or optional remote display.
-
QR codes with embedded data for viewing meter information using Meter Insights.
Alarming
-
Extensive alarming options like unary, digital, standard, logic, custom, and disturbance alarms.
-
The ability to send emails with alarm information.
Communications
-
Dual Ethernet switched ports allow fast Ethernet interconnection to other PM5500 / PM5600 / PM5700 meters using only one IP switch.
-
Ethernet gateway functionality, allowing a Modbus master using Modbus TCP to communicate through the meter to downstream serial devices using Modbus RTU.
-
Support for a variety of Ethernet protocols, such as Modbus TCP, BACnet/IP, EtherNet/IP and DNP3. All the Ethernet protocols can be used at the same time.
-
Enhanced Modbus security using TCP/IP filtering to set the specific IP addresses that are permitted to access the meter.
Measurements and logging
-
4-quadrant, Class 0.2S accurate energy metering.
-
Present, last, predicted and peak (maximum) demand using a selection of demand calculation methods.
-
Highly accurate 1-second measurements.
-
Onboard data logging support for up to 14 selectable parameters.
-
Complete harmonic distortion metering, recording and realtime reporting, up to the 63rd harmonic for all voltage and current inputs.
-
Recording of each new minimum and new maximum value.
Revenue and tariffs
-
Multiple tariff support (8 tariffs) for monitoring energy usage.
-
Models with features to help you comply with revenue and billing standards.
Compliance to international standards
-
IEC 62053-22: 2020, BS/ EN 62053-22 Class 0.5S / Class 0.2S
-
ANSI C12.20 Class 0.2
-
IEC 61557-12: 2021, BS/ EN 61557-12 PMD/S/K70/0.2
-
IEC 62053-23: 2020, BS/ EN 62053-23
-
IEC 62052-11: 2020, BS/ EN 62052-11
-
IEC 62052-31: 2015, BS/ EN 62052-31
-
MID/MIR, BS/ EN 50470-1; BS/ EN 50470-3 – Annex B and Annex D
-
CE and cULus as per BS/ EN/ IEC/ UL 61010-1: 2010 + A1: 2019
-
BACnet/IP - BTL listed (B-ASC)
-
EtherNet/IP - ODVA certified