MTN6710-0102S / MTN6810-0102 / MTN6805-0008

Loads per Channel

  • Incandescent and halogen lamps (ohmic load).

  • Low-voltage halogen lamps with dimmable, wound transformers (inductive load).

  • Low-voltage halogen lamps with dimmable, electronic transformers (capacitive load).

  • combination of ohmic and inductive loads: Halogen and incandescent lamps, halogen lamps with wound transformers.

  • combination of ohmic and capacitive loads: Halogen and incandescent lamps, halogen lamps with electronic transformers, LED or ESL/CFL.

  • Dimmable ESL/CFL.

  • Dimmable LED lamps.

More detailed information on the minimum and maximum permissible loads can be found in the “Technical data” section of the user manual. More information on dimmable LED and energy-saving lamps can be found here.


CAUTION
The device can be damaged.
Read the user manual carefully. The following safety information refer exclusively to the selection of the load.
  • Only operate the device according to the specifications listed in the technical data.
  • Only connect dimmable transformers to the dimmer when you use transformers.
  • Do not connect a combination of capacitive and inductive loads to one channel.
  • Do not connect a combination of LED or ESL/CFL lamps and inductive loads such as wound transformers to one channel.
  • Do not use dimmers on socket outlets. The risk of overload and connecting unsuitable devices is too high.
QR Code is a registered trademark of DENSO WAVE INCORPORATED in Japan and other countries.